Contegra® 200H22 (UDI 00613994600349)Recalls & reported problems

Medtronic, Inc. · CNDT 200H22 CONTEGRA UNSUPP HDE PS · Class f · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
10
Deaths reported
0
Injuries reported
10
Recalls naming it
0

Summary

The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 00613994600349), received between Jun 6, 2017 and Sep 2, 2025 — classified as 10 injuries.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (9 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Device Problem Information9
  • Calcified1
  • Device Operates Differently Than Expected1
  • Gradient Increase1

Patient problems

  • Insufficient Information5
  • No Information4
  • Pulmonary Valve Stenosis3
  • Aortic Valve Stenosis1
  • Regurgitation, Valvular1

Recent adverse event reports

The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.

  • InjurySep 2, 2025Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT 9 YEARS, 11 MONTHS POST IMPLANT OF THIS 22MM CONTEGRA PULMONARY VALVED CONDUIT, IT WAS EXPLANTED AND REPLACED WITH A 22MM CONTEGRA PULMONARY VALVE CONDUIT OF THE SAME MODEL. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 22937594 ↗
  • InjuryOct 11, 2024Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT 7 YEARS AND 10 MONTHS POST IMPLANT OF THIS 22MM PULMONARY VALVED CONDUIT IMPLANTED IN A THEN 3 YEAR OLD PEDIATRIC PATIENT, A TRANSCATHETER PULMONARY BIOPROSTHETIC VALVE (TPBV) WAS IMPLANTED VALVE-IN-VALVE. THE REASON FOR REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 20432641 ↗
  • InjurySep 6, 2023Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT 12 YEARS AND 10 MONTHS POST IMPLANT OF THIS  22MM PULMONARY VALVED CONDUIT, A TRANSCATHETER VALVE WAS IMPLANTED VALVE-IN-VALVE. THE REASON FOR INTERVENTION WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 17689502 ↗
  • InjuryJan 3, 2023Calcified; Gradient Increase; Calcified; Gradient Increase

    MEDTRONIC RECEIVED INFORMATION THAT 2 YEARS 9MONTHS POST IMPLANT OF THIS 22MM PULMONARY VALVED CONDUIT, A BALLOON VALVULOPLASTY OF THE CONDUIT WAS PERFORMED DUE TO STENOSIS. SUBSEQUENTLY 8 YEARS 8 MONTHS LATER, THE PATIENT SUCCESSFULLY HAD A VALVE-IN-VALVE REPLACEMENT WITH A TRANSCATHETER PULMONARY BIOPROSTHETIC VALVE (TPBV). THE REASON FOR REPLACEMENT WAS REPORTED AS SEVERE PULMONARY STENOSIS. IT WAS REPORTED THAT THE 22MM PULMONARY VALVED CONDUIT WAS CALCIFIED. A GRADIENT OF 55MMHG WAS REPORTED AND NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Pulmonary Valve Stenosis

    MAUDE report 16086557 ↗
  • InjuryDec 1, 2022Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT 6 YEARS AND 7 MONTHS POST IMPLANT OF THIS 22MM PULMONARY VALVED CONDUIT IN A 8 YEARS OLD PEDIATRIC PATIENT, A TRANSCATHETER PULMONARY BIOPROSTHETIC VALVE (TPBV) WAS IMPLANTED VALVE-IN-VALVE. THE REASON FOR INTERVENTION WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 15895202 ↗
  • InjuryOct 21, 2022Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT 11 YEARS AND 2 MONTHS POST IMPLANT OF THIS 22MM PULMONARY VALVED CONDUIT IN A 17 YEAR OLD PEDIATRIC PATIENT, A TRANSCATHETER PULMONARY BIOPROSTHETIC VALVE (TPBV) WAS IMPLANTED VALVE-IN-VALVE. THE REASON FOR REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 15655305 ↗
  • InjurySep 26, 2019Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT 8 YEARS AND 7 MONTHS POST IMPLANT OF THIS 22MM PULMONARY VALVED CONDUIT IN A (B)(6)-YEAR-OLD PEDIATRIC PATIENT, IT WAS REPLACED VALVE-IN-VALVE WITH A TRANSCATHETER BIOPROSTHETIC PULMONARY VALVE. THE REASON FOR REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: No Information; Pulmonary Valve Stenosis

    MAUDE report 9124346 ↗
  • InjuryMay 28, 2019Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT 9 YEARS AND 1 MONTH POST IMPLANT OF THIS BIOPROSTHETIC PULMONARY VALVED CONDUIT IMPLANTED IN A PEDIATRIC PATIENT, A TRANSCATHETER PULMONARY VALVE (TPV) WAS IMPLANTED VALVE-IN-VALVE FOR UNKNOWN REASONS. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Aortic Valve Stenosis; No Information

    MAUDE report 8647159 ↗
  • InjuryMar 7, 2019Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT EIGHT YEARS AND SIX MONTHS POST IMPLANT OF THIS 22MM PULMONARY VALVED CONDUIT IMPLANTED IN A PEDIATRIC PATIENT, A TRANSCATHETER PULMONARY VALVE (TPV) DEPLOYED TO 22MM WAS IMPLANTED VALVE-IN-VALVE. THE REASON FOR VALVE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: No Information

    MAUDE report 8400789 ↗
  • InjuryJun 6, 2017Device Operates Differently Than Expected; Insufficient Device Problem Information; Device Operates Differently Than Expected; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT THREE YEARS, TWO MONTHS POST IMPLANT OF THIS BIOPROSTHETIC PULMONIC VALVE IN A PEDIATRIC PATIENT, THIS DEVICE WAS REPLACED VALVE-IN-VALVE WITH A TRANSCATHETER PULMONIC VALVE. NO FAILURE MECHANISM AND NO OTHER ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: No Information; Pulmonary Valve Stenosis; Regurgitation, Valvular

    MAUDE report 6616602 ↗

Other pulmonic valved conduit devices

All pulmonic valved conduit devices →