Contegra® 200H18 (UDI 00643169616929)Recalls & reported problems

Medtronic, Inc. · CNDT 200H18 CONTEGRA UNSUPP HDE · Class f · Implant

All models of Contegra (35)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
12
Deaths reported
0
Injuries reported
11
Recalls naming it
0

Summary

The FDA's MAUDE database contains 12 adverse event reports that list this exact device (DI 00643169616929), received between Mar 19, 2020 and Sep 30, 2026 — classified as 11 injuries, 1 malfunction.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (7 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 2 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Device Problem Information7
  • Adverse Event Without Identified Device or Use Problem2
  • Patient Device Interaction Problem2
  • Device Stenosis1
  • Intravalvular regurgitation1

Patient problems

  • Insufficient Information5
  • Heart Block3
  • No Information2
  • Aneurysm1
  • Endocarditis1
  • Pulmonary Valve Insufficiency/ Regurgitation1
  • Pulmonary Valve Stenosis1

Recent adverse event reports

The 12 most recent of 12 reports, in the reporter's own words as published by the FDA.

  • InjurySep 30, 2026Patient Device Interaction Problem

    Medtronic received information that post implant of this 18mm pulmonary valved conduit on the same day, a Bi-Ventricular pacemaker was implanted. The reason for the Bi-Ventricular pacemaker was reported as complete heart block (CHB). No additional adverse patient effects were reported.

    Patient problems: Heart Block

    MAUDE report 50942975 ↗
  • InjurySep 23, 2026Patient Device Interaction Problem

    Medtronic received information that during the implant of this 18mm pulmonary valved conduit in then a 4 year old pediatric patient, a permanent pacemaker was implanted. The reason for the permanent pacemaker was reported as complete heart block (CHB). No additional adverse patient effects were reported.

    Patient problems: Heart Block

    MAUDE report 50867050 ↗
  • InjuryMar 10, 2026Device Stenosis

    IT WAS REPORTED THAT 7 YEARS AND 2 MONTHS POST IMPLANT OF THIS 18MM PULMONARY VALVE CONDUIT IMPLANTED IN A THEN 4 YEAR OLD PEDIATRIC PATIENT, A TRANSCATHETER VALVE WAS IMPLANTED VALVE-IN-VALVE. THE REASON FOR THE REPLACEMENT WAS REPORTED AS MILD PULMONARY STENOSIS. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Pulmonary Valve Stenosis

    MAUDE report 24560994 ↗
  • InjuryFeb 10, 2026Insufficient Device Problem Information

    IT WAS REPORTED THAT APPROXIMATELY 3 MONTHS POST IMPLANT OF THIS 18MM PULMONARY VALVE CONDUIT IMPLANTED IN A THEN 2-YEAR-OLD PEDIATRIC PATIENT, A 16MM PULMONARY TRANSCATHETER VALVE WAS IMPLANTED VALVE-IN-VALVE. THE REASON FOR INTERVENTION WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 24305207 ↗
  • MalfunctionNov 5, 2024Intravalvular regurgitation; Intravalvular regurgitation

    MEDTRONIC RECEIVED INFORMATION THAT 3 DAYS POST IMPLANT OF THIS 18MM PULMONARY VALVED CONDUIT IMPLANTED IN A THEN 1 YEAR OLD PEDIATRIC PATIENT, IT WAS REPORTED THAT THE DISCHARGE ECHOCARDIOGRAM (ECHO) DISCOVERED CONDUIT REDUNDANCY AND PROLAPSE BACK INTO THE RIGHT VENTRICULAR OUTFLOW TRACT (RVOT). IT WAS ALSO REPORTED THAT THERE IS MILD TO MODERATE PULMONARY REGURGITATION. NO INTERVENTION OR ADDITIONAL ADVERSE PATIENT AFFECTS WERE REPORTED.

    Patient problems: Aneurysm; Pulmonary Valve Insufficiency/ Regurgitation

    MAUDE report 20612803 ↗
  • InjuryMay 14, 2024Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT 5 DAYS POST IMPLANT OF THIS 18MM PULMONARY VALVED CONDUIT IMPLANTED IN A THEN 4 YEAR OLD PEDIATRIC PATIENT, IT WAS EXPLANTED AND REPLACED WITH A 18MM CONDUIT OF THE SAME MODEL. THE REASON FOR REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 19310848 ↗
  • InjurySep 8, 2023Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT 4 YEARS AND 9 MONTHS POST IMPLANT OF THIS 18MM PULMONARY VALVED CONDUIT IMPLANTED IN A THEN 4 YEAR OLD PEDIATRIC PATIENT, IT WAS EXPLANTED AND REPLACED WITH A 22MM CONDUIT OF THE SAME MODEL. THE REASON FOR REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 17711713 ↗
  • InjuryJun 16, 2022Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT AN UNKNOWN DURATION POST IMPLANT OF THIS 18 MM PULMONARY VALVED CONDUIT IN A 6 YEAR OLD PEDIATRIC PATIENT, IT WAS EXPLANTED AND REPLACED WITH A HOMOGRAFT. THE REASON FOR REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Endocarditis; Insufficient Information

    MAUDE report 14717977 ↗
  • InjuryJul 2, 2021Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT 1 MONTH AND 25 DAYS POST IMPLANT OF THIS 18MM PULMONARY VALVED CONDUIT IN A (B)(6)-YEAR-OLD PEDIATRIC PATIENT, IT WAS EXPLANTED AND REPLACED WITH A 22MM CONDUIT OF A DIFFERENT MODEL. THE REASON FOR REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 12108195 ↗
  • InjuryApr 6, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    MEDTRONIC RECEIVED INFORMATION THAT 5 DAYS POST IMPLANT OF THIS 18MM PULMONARY VALVED CONDUIT IN A (B)(6) PEDIATRIC PATIENT, A PERMANENT PACEMAKER WAS IMPLANTED IN THE PATIENT. THE REASON FOR THE PERMANENT PACEMAKER IMPLANT WAS REPORTED AS COMPLETE HEART BLOCK. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Heart Block

    MAUDE report 11625014 ↗
  • InjuryNov 11, 2020Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT 2 YEARS AND 4 MONTHS POST IMPLANT OF THIS 18MM PULMONARY VALVED CONDUIT IN A (B)(6) PEDIATRIC PATIENT, IT WAS EXPLANTED AND REPLACED WITH A 21MM AORTIC ROOT BIOPROSTHESIS IMPLANTED IN THE PULMONARY POSITION. THE REASON FOR REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: No Information

    MAUDE report 10826923 ↗
  • InjuryMar 19, 2020Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT 5 MONTHS POST IMPLANT OF THIS 18MM PULMONARY VALVED CONDUIT IN A (B)(6) YEAR OLD PEDIATRIC PATIENT, IT WAS EXPLANTED AND REPLACED WITH A 18MM CONDUIT OF THE SAME MODEL. THE REASON FOR REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: No Information

    MAUDE report 9853596 ↗

Other pulmonic valved conduit devices

All pulmonic valved conduit devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page