CG FUTURE® 638RL28 (UDI 00613994758637)Recalls & reported problems
Medtronic, Inc. · RING 638RL28 CG FUTURE 10L MEXICO · Class 2 · Implant
All models of CG FUTURE (46)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
Quick summary
This Medtronic CG Future 28 mm annuloplasty ring is a prosthetic ring used to repair the mitral valve in open-heart surgery. The 32 reports mostly describe patients who, years after implantation, needed the ring removed and replaced with a different valve, or who developed mitral valve problems such as regurgitation or stenosis. There were 31 injuries and no deaths. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 33
- Deaths reported
- 0
- Injuries reported
- 32
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 33 adverse event reports that list this exact device (DI 00613994758637), received between Apr 18, 2017 and Jul 27, 2026 — classified as 32 injuries, 1 malfunction.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (20 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Insufficient Device Problem Information20
- Adverse Event Without Identified Device or Use Problem9
- Patient Device Interaction Problem3
- Incomplete Coaptation1
- Intravalvular regurgitation1
- No Apparent Adverse Event1
- Perivalvular Leak1
Patient problems
- No Information10
- Insufficient Information8
- Mitral Regurgitation7
- Mitral Valve Stenosis3
- Mitral Valve Insufficiency/ Regurgitation2
- Arrhythmia1
- Bradycardia1
- Complete Heart Block1
Recent adverse event reports
The 25 most recent of 33 reports, in the reporter's own words as published by the FDA.
InjuryJul 27, 2026Patient Device Interaction Problem
It was reported that 3 days post implant of this 28mm mitral annuloplasty ring, a defibrillator was implanted. The reason for the de fibrillator was not reported. No additional adverse patient effects were reported.
Patient problems: Non specific EKG/ECG Changes
MAUDE report 50036815 ↗InjuryApr 24, 2026Patient Device Interaction Problem
IT WAS REPORTED THAT 12 YEARS AND 10 MONTHS POST IMPLANT OF THIS 28MM MITRAL ANNULOPLASTY RING, A DEFIBRILLATOR WAS IMPLANTED. THE REASON FOR THE DEFIBRILLATOR WAS REPORTED AS HISTORY OF SPONTANEOUS SUSTAINED VENTRICULAR TACHYCARDIA (VT). NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Tachycardia
MAUDE report 24979576 ↗MalfunctionDec 6, 2024Intravalvular regurgitation; Intravalvular regurgitation
MEDTRONIC RECEIVED INFORMATION THAT 10 YEARS AND 1 MONTH POST IMPLANT OF THIS 28MM MITRAL ANNULOPLASTY RING, THE PATIENT IS BEING EVALUATED FOR A TRANSCATHETER VALVE-IN-VALVE REPLACEMENT. THE REASON FOR EVALUATION WAS REPORTED AS MITRAL REGURGITATION. NO INTERVENTION OR ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Mitral Valve Insufficiency/ Regurgitation
MAUDE report 20872543 ↗InjuryNov 18, 2024Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT 6 YEARS AND 10 MONTHS POST IMPLANT OF THIS 28MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED AND R EPLACED WITH A 27MM BIOPROSTHETIC VALVE. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Insufficient Information
MAUDE report 20708295 ↗InjuryAug 20, 2024Patient Device Interaction Problem; Patient Device Interaction Problem
MEDTRONIC RECEIVED INFORMATION THAT 5 YEARS AND 8 MONTHS POST IMPLANT OF THIS 28MM MITRAL ANNULOPLASTY RING, A REPLACEMENT PERMANENT PACEMAKER WAS IMPLANTED. THE REASON FOR THE REPLACEMENT PERMANENT PACEMAKER WAS REPORTED AS SINUS BRADYCARDIA. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Bradycardia
MAUDE report 20000921 ↗InjuryOct 12, 2023Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT DURING THE IMPLANT OF THIS 28MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED AND REPLACED WITH AN UNKNOWN DEVICE. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Insufficient Information
MAUDE report 17920613 ↗InjurySep 12, 2022Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT APPROXIMATELY 9 YEARS POST IMPLANT OF THIS 28 MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED AND REPLACED WITH A 25 MM MITRAL BIOPROSTHETIC VALVE. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Insufficient Information; Mitral Valve Insufficiency/ Regurgitation; Mitral Valve Stenosis
MAUDE report 15402943 ↗InjuryAug 4, 2021Incomplete Coaptation; Insufficient Device Problem Information; Incomplete Coaptation; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION FROM THE PATIENT THAT 3 YEARS AND 11 MONTHS POST IMPLANT OF THIS 28MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED AND REPLACED WITH A 27MM NON-MEDTRONIC VALVE "BECAUSE THE VALVE CLOSED". NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Insufficient Information; Mitral Valve Stenosis
MAUDE report 12276393 ↗InjuryJul 7, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
MEDTRONIC RECEIVED INFORMATION THAT THIS PATIENT UNDERWENT SURGERY DUE TO ENDOCARDITIS. THE SURGEON ATTEMPTED TO REPAIR THE MITRAL VALVE WITH THIS ANNULOPLASTY RING, BUT ULTIMATELY THE PATIENT REQUIRED A COMPLETE VALVE REPLACEMENT. NO MALFUNCTION OF THE ANNULOPLASTY BAND WAS REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Insufficient Information
MAUDE report 12131379 ↗InjuryJun 28, 2021Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT 7 YEARS AND 2 MONTHS POST IMPLANT OF THIS 28MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED AND REPLACED WITH A 28MM MITRAL ANNULOPLASTY RING. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Insufficient Information
MAUDE report 12076079 ↗InjuryMar 29, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
MEDTRONIC RECEIVED INFORMATION THAT 2 MONTHS POST IMPLANT OF THIS 28MM MITRAL ANNULOPLASTY RING, A PERMANENT PACEMAKER WAS IMPLANTED. THE REASON FOR THE PERMANENT PACEMAKER WAS REPORTED AS 3RD DEGREE ATRIOVENTRICULAR BLOCK (COMPLETE HEART BLOCK). NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Heart Block
MAUDE report 11581685 ↗InjuryMar 29, 2021Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT 1 YEAR AND 3 MONTH POST IMPLANT OF THIS 28MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED AND REPLACED WITH A 25MM BIOPROSTHETIC VALVE. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Insufficient Information
MAUDE report 11581005 ↗InjuryOct 14, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
MEDTRONIC RECEIVED INFORMATION THAT 4 DAYS POST IMPLANT OF THIS 28MM MITRAL ANNULOPLASTY RING, A PERMANENT PACEMAKER WAS IMPLANTED DUE TO COMPLETE HEART BLOCK. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Complete Heart Block
MAUDE report 10676006 ↗InjuryOct 7, 2020Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT 6 YEARS AND 6 MONTHS POST IMPLANT OF THIS 28MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED AND REPLACED WITH A 27MM BIOPROSTHETIC VALVE. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Insufficient Information; No Information
MAUDE report 10645509 ↗InjurySep 23, 2020Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT 1 YEAR AND 8 MONTHS POST IMPLANT OF THIS 28MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED AND REPLACED WITH A 25MM MITRAL BIOPROSTHETIC VALVE DUE TO SEVERE MITRAL REGURGITATION. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Mitral Regurgitation
MAUDE report 10578193 ↗InjuryMay 1, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
MEDTRONIC RECEIVED INFORMATION THAT 2 YEARS AND 6 MONTHS POST IMPLANT OF THIS 28MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED AND REPLACED WITH A 27MM MITRAL VALVE DUE TO DEHISCENCE OF THE RING. THE SURGEON REPORTED THAT THE SUTURES PULLED THROUGH THE TISSUE AND THERE WAS NO ISSUE WITH THE RING. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: No Information
MAUDE report 10017309 ↗InjuryDec 17, 2019Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT IMMEDIATELY POST IMPLANT OF THIS MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED DUE TO AN UNSUCCESSFUL REPAIR ATTEMPT. THE REASON FOR VALVE REPLACEMENT AS OPPOSED TO REPAIR WAS NOT PROVIDED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: No Information
MAUDE report 9482262 ↗InjuryJun 14, 2019Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT IMMEDIATELY POST IMPLANT OF THIS MITRAL ANNULOPLASTY RING, THE RING WAS EXPLANTED AND REPLACED WITH A NON-MEDTRONIC VALVE. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: No Information
MAUDE report 8699683 ↗InjuryFeb 20, 2019Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT 5 YEARS AND 11 MONTHS POST IMPLANT OF THIS MITRAL ANNULOPLASTY RING, THE RING WAS EXPLANTED AND REPLACED WITH A BIOPROSTHETIC VALVE. THE REASON FOR THE EXPLANT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Mitral Regurgitation; Mitral Valve Stenosis; No Information
MAUDE report 8355998 ↗InjuryNov 28, 2018Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT IMMEDIATELY POST IMPLANT OF THIS 28MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED AND REPLACED WITH A 27MM BIOPROSTHETIC VALVE. ACCORDING TO THE SURGEON, THIS PATIENT'S NATIVE VALVE ANNULUS WAS DILATED, THERE WAS SEVERE TETHERING OF THE POSTERIOR LEAFLET AND MILD THICKENING OF THE ANTERIOR LEAFLET. ADDITIONALLY, THE PAPILLARY MUSCLES TO THE POSTERIOR LEAFLET WERE "SOMEWHAT DRAWN UP INTO THE LEAFLET ITSELF." AFTER SUTURING THE RING INTO PLACE, SALINE TESTING DEMONSTRATED TRIVIAL REGURGITATION. ALL CANNULAE WERE LEFT IN PLACE AND CARDIOPULMONARY BYPASS (CPB) WAS DISCONTINUED. THE POST-CPB TRANSESOPHAGEAL ECHOCARDIOGRAM (TEE) DEMONSTRATED MODERATE RESIDUAL REGURGITATION. THE PATIENT WAS PLACED BACK ON CPB, THE RING WAS EXPLANTED, AND A BIOPROSTHETIC VALVE WAS SUCCESSFULLY IMPLANTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Mitral Regurgitation
MAUDE report 8111167 ↗InjuryOct 19, 2018No Apparent Adverse Event; No Apparent Adverse Event
MEDTRONIC RECEIVED INFORMATION THAT IMMEDIATELY POST IMPLANT OF THIS MITRAL ANNULOPLASTY RING, THE RING WAS EXPLANTED AND REPLACED WITH A BIOPROSTHETIC VALVE. THE SURGEON REPORTED THE RING DID NOT FAIL BUT A SATISFACTORY REPAIR WAS UNABLE TO BE ACHIEVED DUE TO PATIENT TISSUE PROBLEMS. MODERATE REGURGITATION WAS ULTIMATELY THE REASON FOR THE EXPLANT. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Failure of Implant; Mitral Regurgitation
MAUDE report 7986297 ↗InjuryJul 30, 2018Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT IMMEDIATELY POST IMPLANT OF THIS ANNULOPLASTY RING, "WATER INJECTION AND ULTRASOUND" TESTING REVEALED RESIDUAL REGURGITATION. THE RING WAS EXPLANTED AND REPLACED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Regurgitation; Regurgitation, Valvular
MAUDE report 7732162 ↗InjuryMay 4, 2018Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT DURING THE IMPLANT OF THIS ANNULOPLASTY RING, THE RING WAS EXPLANTED AND REPLACED. THE REASON FOR REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: No Information
MAUDE report 7488029 ↗InjuryApr 30, 2018Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT DURING THE IMPLANT OF THIS ANNULOPLASTY RING, THE RING WAS EXPLANTED AND REPLACED WITH A BIOPROSTHETIC VALVE. THE REASON FOR REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: No Information
MAUDE report 7473968 ↗InjuryFeb 13, 2018Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT THIS 28MM MITRAL ANNULOPLASTY RING WAS IMPLANTED AND EXPLANTED DURING THE SAME PROCEDURE FOR UNKNOWN REASONS. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: No Information
MAUDE report 7267519 ↗
Other RING, ANNULOPLASTY devices
- CG FUTURE™ 638BL32Medtronic, Inc. · RING, ANNULOPLASTY1 death71 reports
- PROFILE 3D® 680R28Medtronic, Inc. · RING, ANNULOPLASTY1 death67 reports
- CG FUTURE™ 638BL30Medtronic, Inc. · RING, ANNULOPLASTY1 death65 reports
- CG FUTURE™ 638RL32Medtronic, Inc. · RING, ANNULOPLASTY59 reports
- Tri-Ad™ 900SFC228Medtronic, Inc. · RING, ANNULOPLASTY4 deaths56 reports
- CG FUTURE™ 638BL34Medtronic, Inc. · RING, ANNULOPLASTY51 reports
- Contour 3D® 690R30Medtronic, Inc. · RING, ANNULOPLASTY1 death50 reports
- CG FUTURE™ 638BL28Medtronic, Inc. · RING, ANNULOPLASTY1 death47 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page