CD Horizon® Spinal System 55740007540Recalls & reported problems
Medtronic Sofamor Danek, Inc. · SCREW 55740007540 5.5/6 MAS 7.5X40 CC S · Class 2 · Implant
All models of CD HORIZON Spinal System (342)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00613994996091), received between Apr 6, 2022 and Apr 6, 2022 — classified as 2 injuries.
The most frequently reported specific device problem is “Loosening of Implant Not Related to Bone-Ingrowth” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Loosening of Implant Not Related to Bone-Ingrowth2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryApr 6, 2022Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth
INFORMATION WAS RECEIVED FROM A HEALTHCARE PROVIDER VIA A MANUFACTURER REPRESENTATIVE REGARDING A ROD AND SCREWS IMPLANTED IN A PATIENT. PROCEDURE PERFORMED IN THE INITIAL SURGERY WAS T9/S2 WAS FIXATED WITH PSF FROM DEGENERATIVE KYPHOSCOLIOSIS. PRE-OP DIAGNOSIS FOR THE REVISION SURGERY WAS BROKEN ROD, SAI SET SCREW DISLODGEMENT ON BOTH SIDES, BILATERAL S1 SCREW AND LEFT SAI SCREW LOOSENING. PROCEDURE PERFORMED IN REVISION SURGERY WAS BOTH SIDES OF S1 SCREWS AND THE LEFT SAI SCREW WERE REPLACED. IT WAS REPORTED THAT THE INITIAL SURGERY WAS PERFORMED ON (B)(6) 2021, BUT DUE TO THE BROKEN ROD, REOPERATION WAS PERFORMED ON (B)(6) 2021. A REOPERATION WAS PERFORMED BECAUSE THE ROD WAS BROKEN AGAIN, THE SET SCREW USED FOR THE SAI SCREW CAME OFF, AND THE SCREW BECAME LOOSE. THE PHYSICIAN REQUESTED THAT THE SCREW HEAD OF THE SAI SCREW THREAD BE CHECKED FOR DAMAGE. THERE WERE NO PATIENT SYMPTOMS OR COMPLICATIONS AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14024669 ↗InjuryApr 6, 2022Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth
INFORMATION WAS RECEIVED FROM A HEALTHCARE PROVIDER VIA A MANUFACTURER REPRESENTATIVE REGARDING A ROD AND SCREWS IMPLANTED IN A PATIENT. PROCEDURE PERFORMED IN THE INITIAL SURGERY WAS T9/S2 WAS FIXATED WITH PSF FROM DEGENERATIVE KYPHOSCOLIOSIS. PRE-OP DIAGNOSIS FOR THE REVISION SURGERY WAS BROKEN ROD, SAI SET SCREW DISLODGEMENT ON BOTH SIDES, BILATERAL S1 SCREW AND LEFT SAI SCREW LOOSENING. PROCEDURE PERFORMED IN REVISION SURGERY WAS BOTH SIDES OF S1 SCREWS AND THE LEFT SAI SCREW WERE REPLACED. IT WAS REPORTED THAT THE INITIAL SURGERY WAS PERFORMED ON (B)(6) 2021, BUT DUE TO THE BROKEN ROD, REOPERATION WAS PERFORMED ON (B)(6) 2021. A REOPERATION WAS PERFORMED BECAUSE THE ROD WAS BROKEN AGAIN, THE SET SCREW USED FOR THE SAI SCREW CAME OFF, AND THE SCREW BECAME LOOSE. THE PHYSICIAN REQUESTED THAT THE SCREW HEAD OF THE SAI SCREW THREAD BE CHECKED FOR DAMAGE. THERE WERE NO PATIENT SYMPTOMS OR COMPLICATIONS AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14024456 ↗
Other Thoracolumbosacral pedicle screw system devices
- EXPEDIUM VERSE 199721000Medos International Sàrl · Orthosis, spinal pedicle fixation, for degenerative disc disease387 reports
- Sequoia® 3301-1Zimmer Spine, Inc. · Orthosis, spinal pedicle fixation, for degenerative disc disease184 reports
- CD HORIZON® Spinal System 8590855Medtronic Sofamor Danek, Inc. · Orthosis, spinal pedicle fixation, for degenerative disc disease179 reports
- Vitality® 07.02011.001Biomet Spine LLC · Orthosis, spinal pedicle fixation, for degenerative disc disease3 recalls0 reports
- EXPEDIUM VERSE 199721001SMedos International Sàrl · Thoracolumbosacral pedicle screw system124 reports
- LineSider LS-N6SA7550Integrity Implants Inc. · Thoracolumbosacral Pedicle Screw System2 recalls1 report
- LineSider LS-N6SA6545Integrity Implants Inc. · Thoracolumbosacral Pedicle Screw System2 recalls0 reports
- EXPEDIUM VERSE 199721000SMedos International Sàrl · Thoracolumbosacral pedicle screw system97 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page