Atellica CH TACR 11097542Recalls & reported problems

Siemens Healthcare Diagnostics Inc. · Tacrolimus (TACR) Atellica CH - RGT 400T · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00630414238340), received between Dec 14, 2023 and Sep 15, 2026 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Low Test Results” (3 reports).

1 other recall cover devices cleared under the same FDA submission (K060385); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 2 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Low Test Results3
  • High Test Results1
  • Incorrect, Inadequate or Imprecise Result or Readings1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 15, 2026Low Test Results

    The customer reported that they obtained erroneously depressed Tacrolimus (TACR) results on two patient samples on an Atellica CH 930 Analyzer.The initial results were reported to the physician(s) and were questioned. The samples were repeated on an alternate Atellica CH 930 Analyzer, and the results recovered higher than the initial results and were considered correct. Corrected reports were issued with the repeat results. There are no known reports of patient intervention or adverse health consequences due to the erroneously depressed TACR results.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50771391 ↗
  • MalfunctionFeb 24, 2025Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    THE CUSTOMER REPORTED TO SIEMENS THAT THEY OBTAINED DISCORDANT TACROLIMUS (TACR) RESULTS ON MULTIPLE PATIENT SAMPLES ON AN ATELLICA CH 930 ANALYZER. THE INITIAL RESULTS WERE REPORTED TO THE PHYSICIAN. THE SAME SAMPLES WERE REPROCESSED ON THE SAME ATELLICA CH 930 ANALYZER. THE REPROCESSED RESULTS OBTAINED WERE CONSIDERED CORRECT AND REPORTED TO THE PHYSICIAN. THE CUSTOMER DECLINED TO PROVIDE THE PATIENT SAMPLE DATA. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE DISCORDANT TACROLIMUS (TACR) RESULTS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21444007 ↗
  • MalfunctionDec 14, 2023High Test Results; Low Test Results; High Test Results; Low Test Results

    DISCORDANT ELEVATED TACROLIMUS (TACR) RESULTS WERE OBTAINED ON SAMPLES FROM TWO PATIENTS ON AN ATELLICA CH 930 INSTRUMENT (S/N(B)(6)). THE INITIAL RESULTS WERE REPORTED TO THE PHYSICIAN(S), WHO QUESTIONED THE RESULTS. THE SAMPLES WERE REPEATED ON THE SAME ATELLICA CH 930 INSTRUMENT. THE REPEAT RESULTS WERE LOWER THAN THE INITIAL RESULTS. CORRECTED REPORT(S) WERE ISSUED. THE PATIENTS WERE BOTH ORGAN TRANSPLANT RECIPIENTS. THERE ARE NO KNOWN REPORTS ADVERSE HEALTH CONSEQUENCES DUE TO THE DISCORDANT ELEVATED TACROLIMUS (TACR) RESULTS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18325509 ↗
  • MalfunctionDec 14, 2023Low Test Results; Low Test Results

    THE CUSTOMER OBTAINED AN ABOVE ASSAY RANGE RESULT FOR TACROLIMUS (TACR) ON A PATIENT SAMPLE WHEN PROCESSED ON AN ATELLICA CH 930 INSTRUMENT (S/N (B)(6)). THE PATIENT SAMPLE WAS DILUTED AND REPEATED. THE RESULTS WERE LOWER AND WITHIN THE ASSAY RANGE. THE LOWER DILUTED RESULT WAS REPORTED TO THE PHYSICIAN(S) AND WAS QUESTIONED. A NEW SAMPLE FROM THE SAME PATIENT WAS TESTED AND THE RESULT WAS HIGHER AND CONSIDERED TOXIC. THE INITIAL SAMPLE WAS REPEATED AND THE NEAT RESULT WAS SIMILAR TO THE NEW SAMPLE RESULT. THE PATIENT IS AN ORGAN TRANSPLANT RECIPIENT AND WAS GIVEN TACROLIMUS TREATMENT. THE TRANSPLANT TIME FRAME WAS NOT PROVIDED FOR THE PATIENT. THERE ARE NO KNOWN REPORTS ADVERSE HEALTH CONSEQUENCES DUE TO THE DISCORDANT TACROLIMUS (TACR) RESULTS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18325390 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K060385. One submission often covers many models, so check the product and lot details in each record.

  • Z-1661-2018 · Jun 29, 2017 · Terminated
    Syva Emit 2000 Tacrolimus Assay (Product Number: 8R019UL/10445397) (Mfr: Siemens Healthcare Diagnostics, Newark, DE)

Other ENZYME IMMUNOASSAY, TRACROLIMUS devices

All ENZYME IMMUNOASSAY, TRACROLIMUS devices →