Atellica IM Rub M 10995668Recalls & reported problems
Siemens Healthcare Diagnostics Inc. · Rubella IgM (Rub M) Atellica IM - RGT 50T · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00630414599830), received between Sep 15, 2023 and Sep 15, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “False Negative Result” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- False Negative Result1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 15, 2023False Negative Result; False Negative Result
THE CUSTOMER REPORTS OBSERVATION OF NEGATIVE (NONREACTIVE) ATELLICA IM RUBELLA IGM (RUBM) RESULTS WHICH WERE DISCORDANT RELATIVE TO ALTERNATE-METHOD TESTING. RUBM KIT LOT 211 WAS IN USE AT THE TIME. A SAMPLE FROM A PREGNANT FEMALE PATIENT WAS SENT FROM A RELATED LAB FOR CONFIRMATORY TESTING, FOLLOWING AN INITIAL POSITIVE RUBELLA IGM RESULT. ON (B)(6) 2023, THIS SAMPLE WAS TESTED USING ATELLICA IM RUBM, AND PRODUCED A NONREACTIVE (NEGATIVE) RESULT ¿ IN CONFLICT WITH THE INITIAL POSITIVE RESULT. THE SOURCE LAB ALSO SENT THE SAMPLE IN QUESTION TO AN EXTERNAL REFERENCE LAB, WHICH CONFIRMED THE INITIAL POSITIVE RESULT. THE POSITIVE RESULT WAS ACCEPTED AS CORRECT. THERE ARE NO ALLEGATIONS OF PATIENT HARM, CHANGES IN TREATMENT, OR DELAYS OF DIAGNOSIS DUE TO THE OBSERVED DISCORDANCE. THE RESULT DISAGREEMENT WAS REPRODUCED IN LATER INVESTIGATIONAL TESTING. WHEN THE CUSTOMER RE-TESTED THE SAMPLE USING TWO ATELLICA IM INSTRUMENTS ON (B)(6) 2023, ADDITIONAL NONREACTIVE RUBM RESULTS WERE PRODUCED. THE SAMPLE WAS ADDITIONALLY TESTED USING ANOTHER ALTERNATE METHOD, AND A POSITIVE RESULT WAS OBTAINED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17757172 ↗
Other ENZYME LINKED IMMUNOABSORBENT ASSAY, RUBELLA devices
- VIDAS® RUB IgG 30226Biomerieux SA · Enzyme Linked Immunoabsorbent Assay, Rubella2 recalls0 reports
- Elecsys Rubella IgG 07027770190Roche Diagnostics GmbH · ENZYME LINKED IMMUNOABSORBENT ASSAY, RUBELLA21 reports
- ADVIA Centaur® Rub G 10310283Siemens Healthcare Diagnostics Inc. · ENZYME LINKED IMMUNOABSORBENT ASSAY, RUBELLA16 reports
- Atellica IM Rub G 10995670Siemens Healthcare Diagnostics Inc. · ENZYME LINKED IMMUNOABSORBENT ASSAY, RUBELLA4 reports
- Elecsys Rubella IgM 07027796190Roche Diagnostics GmbH · ENZYME LINKED IMMUNOABSORBENT ASSAY, RUBELLA4 reports
- Elecsys Rubella IgG Immunoassay 4618793160Roche Diagnostics GmbH · ENZYME LINKED IMMUNOABSORBENT ASSAY, RUBELLA1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page