IMMULITE®/IMMULITE® 1000 Systems HCG 10381161Recalls & reported problems
Siemens Healthcare Diagnostics Products Ltd · HCG Total - IMMULITE - RGT - 100 Tests · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00630414963716), received between Feb 14, 2023 and Apr 10, 2024 — classified as 3 malfunctions.
The most frequently reported specific device problem is “High Test Results” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- High Test Results3
Patient problems
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 10, 2024High Test Results; High Test Results
A FALSELY ELEVATED HCG RESULT WAS OBTAINED ON A PATIENT SAMPLE ON AN IMMULITE 1000 INSTRUMENT. THE ERRONEOUS RESULT WAS REPORTED TO THE PHYSICIAN(S), WHO QUESTIONED THE RESULT. THE SAMPLE WAS REPEATED USING AN ALTERNATE PLATFORM. THE REPEAT RESULT WAS LOWER THAN THE ERRONEOUS RESULT AND WAS IN ALIGNMENT WITH THE CLINICAL PICTURE OF THE PATIENT. THE REPEAT RESULT WAS REPORTED, AS THE CORRECT RESULT, TO THE PHYSICIAN(S). THERE ARE NO ALLEGATIONS OF PATIENT HARM, CHANGES IN TREATMENT OR DELAYS IN DIAGNOSIS IN ASSOCIATION WITH THE OBSERVED ERRONEOUS RESULT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19080965 ↗MalfunctionApr 10, 2024High Test Results; High Test Results
A FALSELY ELEVATED HCG RESULT WAS OBTAINED ON A PATIENT SAMPLE ON AN IMMULITE 1000 INSTRUMENT. THE ERRONEOUS RESULT WAS REPORTED TO THE PHYSICIAN(S), WHO QUESTIONED THE RESULT. THE SAMPLE WAS REPEATED USING AN ALTERNATE PLATFORM. THE REPEAT RESULT WAS NEGATIVE AND WAS IN ALIGNMENT WITH THE CLINICAL PICTURE OF THE PATIENT. THE REPEAT RESULT WAS REPORTED, AS THE CORRECT RESULT, TO THE PHYSICIAN(S). THERE ARE NO ALLEGATIONS OF PATIENT HARM, CHANGES IN TREATMENT OR DELAYS IN DIAGNOSIS IN ASSOCIATION WITH THE OBSERVED ERRONEOUS RESULT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19080955 ↗MalfunctionFeb 14, 2023High Test Results; High Test Results
THE CUSTOMER INDICATED THERE WAS A DISCREPANT RESULT ON ONE PATIENT SAMPLE ON AN IMMULITE 1000 ANALYZER, SERIAL NUMBER (B)(4), WHEN USING IMMULITE 1000 HUMAN CHORIONIC GONADOTROPIN (HCG) REAGENT LOT 511. THE DISCORDANT RESULT WAS NOT REPORTED TO THE PHYSICIAN(S). THE SAMPLE WAS REPEATED ON THE SAME ANALYZER AND THE REPEAT RESULT WAS REPORTED TO THE PHYSICIAN(S). THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE DISCORDANT RESULT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16371136 ↗
Other SYSTEM, TEST, HUMAN CHORIONIC GONADOTROPIN devices
- IMMULITE® 2000 Systems HCG 10381206Siemens Healthcare Diagnostics Products Ltd · SYSTEM, TEST, HUMAN CHORIONIC GONADOTROPIN1 recall173 reports
- ARCHITECT 7K78-25Abbott Ireland · SYSTEM, TEST, HUMAN CHORIONIC GONADOTROPIN176 reports
- ARCHITECT 7K78-30Abbott Ireland · SYSTEM, TEST, HUMAN CHORIONIC GONADOTROPIN110 reports
- i-STAT 05p58-25Abbott Point Of Care Inc. · System, Test, Human Chorionic Gonadotropin105 reports
- IMMULITE® 2000 Systems HCG 10381194Siemens Healthcare Diagnostics Products Ltd · SYSTEM, TEST, HUMAN CHORIONIC GONADOTROPIN1 recall16 reports
- Alinity 07P5121Abbott Ireland · SYSTEM, TEST, HUMAN CHORIONIC GONADOTROPIN1 recall15 reports
- Elecsys HCG+beta 07251025190Roche Diagnostics GmbH · SYSTEM, TEST, HUMAN CHORIONIC GONADOTROPIN58 reports
- Elecsys HCG Test System 3271749160Roche Diagnostics GmbH · SYSTEM, TEST, HUMAN CHORIONIC GONADOTROPIN39 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page