IMMULITE®/IMMULITE® 1000 Systems VB Vitamin B12 10380900Recalls & reported problems
Siemens Healthcare Diagnostics Products Ltd · Vitamin B12 - IMMULITE - RGT - 100 Tests · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00630414964874), received between Jan 4, 2019 and Jan 4, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Leak/Splash” (1 report).
1 other recall cover devices cleared under the same FDA submission (K971177); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Leak/Splash1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 4, 2019Leak/Splash; Leak/Splash
SIEMENS WAS INFORMED THAT WHILE USING THE VITAMIN B12 BORATE KCN BUFFER SOLUTION, 20-30 ML OF THE BUFFER SPILLED ON THE OPERATOR'S LEGS. THE OPERATOR'S SKIN WAS RED AT THE SITE OF THE BUFFER CONTACT AREA BUT FADED AFTER A SHORT PERIOD OF TIME. THE CUSTOMER INFORMED SIEMENS THAT THE OPERATOR WAS WEARING GLOVES AT THE TIME OF USE. THE OPERATOR CONSULTED A PHYSICIAN(S). IT IS UNKNOWN IF ANY MEDICAL TREATMENT WAS RENDERED. THERE WAS NO REPORT OF ADVERSE HEALTH CONSEQUENCES DUE TO THE SPILL OF THE BUFFER SOLUTION ON THE OPERATOR.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8217112 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K971177. One submission often covers many models, so check the product and lot details in each record.
- Z-1686-2018 · Jan 2, 2018 · TerminatedIMMULITE /IMMULITE 1000 Vitamin B12
Other RADIOASSAY, VITAMIN B12 devices
- Access Vitamin B12 33000Beckman Coulter, Inc. · Radioassay, Vitamin B121 recall16 reports
- ADVIA Centaur® CKMB MCM 10309782Siemens Healthcare Diagnostics Inc. · RADIOASSAY, VITAMIN B121 recall0 reports
- Atellica IM VB12 10995715Siemens Healthcare Diagnostics Inc. · RADIOASSAY, VITAMIN B1224 reports
- Elecsys Vitamin B12 II 07028121190Roche Diagnostics GmbH · RADIOASSAY, VITAMIN B1221 reports
- Atellica IM VB12 10995714Siemens Healthcare Diagnostics Inc. · RADIOASSAY, VITAMIN B1213 reports
- ADVIA Centaur® VB12 10309970Siemens Healthcare Diagnostics Inc. · RADIOASSAY, VITAMIN B128 reports
- ARCHITECT 7K61-37Abbott Ireland · RADIOASSAY, VITAMIN B124 reports
- ARCHITECT 7K61-27Abbott Ireland · RADIOASSAY, VITAMIN B123 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page