Skip to content

EVEREST™ AC3200 (UDI 00643169014800)Recalls & reported problems

Medtronic, Inc. · INFLATION DEV AC3200 EVEREST 30 TJM · Class 2

All models of EVEREST (6)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00643169014800), received between Apr 27, 2017 and Apr 27, 2017 — classified as 1 malfunction.

The most frequently reported specific device problem is “Unable to Obtain Readings” (1 report).

3 other recalls cover devices cleared under the same FDA submission (K960983); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Unable to Obtain Readings1

Patient problems

  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 27, 2017Unable to Obtain Readings; Unable to Obtain Readings

    THE PHYSICIAN INTENDED TO USE AN EVEREST INFLATION DEVICE. THE DEVICE WAS REMOVED FROM PACKAGING PER IFU, INSPECTED AND PREPPED; NO DEFECTS NOTED. IT IS REPORTED THAT DURING USE WHEN PRESSURE WAS APPLIED TO THE DEVICE, THE NEEDLE DID NOT MOVE. INFLATION DEVICE WAS ATTACHED TO THE NON MDT BALLOON HUB AND INSERTED INTO THE PATIENT VESSEL. THE NURSE APPLIED PRESSURE TO THE INFLATION DEVICE THAT WAS PREPARED AS PER INSTRUCTIONS FOR USE. AS THE NURSE WAS TURNING THE HANDLE, THE PRESSURE NEEDLE ON THE GAUGE REMAINED AT ZERO. IT DID NOT REGISTER PRESSURE. AN X-RAY IMAGE WAS TAKEN AND THE BALLOON HAD BURST. HOWEVER, THE VESSEL DIDN'T RUPTURE OR DISSECT. A NEW AC3200 AND BALLOON WERE USED. THE BALLOON WAS ABLE TO BE INFLATED AND THE CASE COMPLETED SUCCESSFULLY. NO PATIENT INJURY REPORTED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6525272 ↗

FDA clearance and classification

Cleared through 510(k) K960983 on May 30, 1996 (decision: Substantially Equivalent). Submitted by Medtronics Interventional Vascular as “Medtronic Everst 30 Inflation Device/Survival Kit”. The FDA review took 80 days. FDA record ↗

The FDA regulates product code MAV (syringe, balloon inflation) under 21 CFR 870.1650 as a Class II device. 21 CFR 870.1650 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K960983. One submission often covers many models, so check the product and lot details in each record.

  • Z-2271-2010 · Jul 16, 2010 · Terminated
    Medtronic Everest 20 Disposable Inflation Device, AC2200. Used to inflate/deflate balloon catheters as well as to monitor pressure within the balloon.
  • Z-2273-2010 · Jul 16, 2010 · Terminated
    Medtronic Everest 30 Disposable Inflation Device, AC3205P. Used to inflate/deflate balloon catheters as well as to monitor pressure within the balloon.
  • Z-2272-2010 · Jul 16, 2010 · Terminated
    Medtronic Everest 30 Disposable Inflation Device, AC3200. Used to inflate/deflate balloon catheters as well as to monitor pressure within the balloon.

Common questions about the EVEREST™ AC3200

Has the EVEREST™ AC3200 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00643169014800), based on the FDA recall file dated Nov 27, 2026. However, 3 recalls involve devices cleared under the same FDA submission. They may or may not include this model, so check the product, model and lot details in those records.

What problems have been reported with the EVEREST™ AC3200?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Apr 27, 2017. That report lists device problem “Unable to Obtain Readings” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the EVEREST™ AC3200?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the EVEREST™ AC3200 FDA approved?

It was cleared through 510(k) K960983 on May 30, 1996. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the EVEREST™ AC3200, and is it still sold?

The FDA's device database lists Medtronic, Inc. as the company responsible for it (brand EVEREST™, model AC3200). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Syringe, balloon inflation devices

All Syringe, balloon inflation devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page