GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T45010Recalls & reported problems
Medtronic Sofamor Danek, Inc. · DBM T45010 10CC PASTE GRAFTON PLUS · Class 2 · Implant
All models of GRAFTONand GRAFTON PLUSDemineralized Bone Matrix (DBM) (25)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
2 open recalls name this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 2
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00643169123038), received between Aug 1, 2022 and Aug 5, 2022 — classified as 2 injuries.
The most frequently reported specific device problem is “Biocompatibility” (1 report).
2 FDA recall records name this device's identifier, 2 still open.
13 other recalls cover devices cleared under the same FDA submission (K043048); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Recalls naming this device
- Sep 26, 2023Class IIOpen, Classified
Specific serial numbers of GraftonTM DBM product due to the potential that a step during the inspection of the outer Tyvek pouch may not have been performed according to requirements. Based on this, batches may have been released with potential non-conformances in the outer Tyvek pouch.
Z-0166-2024 · Root cause: Employee error · Recall details · FDA record ↗
- Feb 8, 2023Class IIOpen, Classified
Potential for packaging non-conformances directly related to the dual-barrier, sterile pouch packaging system. Non-conforming packaging may lead to a breach in the sterile barrier.
Z-1329-2023 · Root cause: Process control · Recall details · FDA record ↗
Most reported problems
Device problems
- Biocompatibility1
- Patient-Device Incompatibility1
Patient problems
- Hypersensitivity/Allergic reaction2
- Muscle Weakness/Atrophy1
- Nervous System Injury1
- Spinal Cord Injury1
- Swelling/ Edema1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryAug 5, 2022Biocompatibility; Biocompatibility
INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT POSTERIOR CERVICAL DECOMPRESSION/FUSION C4-7 DUE TO CERVICAL TUMOR (SCHWANOMA) IT WAS REPORTED THAT SURGEON HAD TO TAKE PATIENT BACK TO SURGERY DUE TO A CORD COMPRESSION FROM A FLUID COLLECTION. THE FLUID COLLECTION WASN'T BLOOD OR PUS. IT HAD THE APPEARANCE OF INFLAMMATORY FLUID AND HAD GRAFTON DBM MIXED IN WITH IT. IT IS SUSPECTED THAT THE PATIENT MIGHT HAVE HAD AN ALLERGIC REACTION TO ONE OF THE PROCESSING SOLUTIONS IN DBM (SURFACTANT OR ANTIBIOTICS). IT WAS ONLY MIXED WITH PATIENT OWN BONE. SINCE IT WASN'T A HEMATOMA, INFECTION, OR CSF LEAK, AND SINCE GRAFTON WAS FOUND MIXED IN THE COLLECTION, SURGEON BELIEVES IT WAS LIKELY A RARE ALLERGIC REACTION. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.
Patient problems: Hypersensitivity/Allergic reaction; Spinal Cord Injury; Swelling/ Edema
MAUDE report 15173272 ↗InjuryAug 1, 2022Patient-Device Incompatibility
THE PATIENT UNDERWENT POSTERIOR CERVICAL DECOMPRESSION AND FUSION FOR RESECTION OF A TUMOR. MEDTRONIC GRAFTON PLUS DBM (A STANDARD BONE GRAFT USED IN SPINE SURGERY) WAS USED AS ALLOGRAFT TO SUPPLEMENT THE LOCAL AUTOGRAFT. IT WAS APPLIED TO THE FACET JOINTS IN STANDARD FASHION. THE SPINAL CORD WAS COMPLETELY FREE OF COMPRESSION AT WOUND CLOSURE. A SURGICAL DRAIN WAS PLACED AND REMOVED POSTOP DAY 2 AFTER OUTPUT WAS SATISFACTORILY LOW. THE PATIENT WAS NEUROLOGICALLY STABLE UNTIL POSTOP DAY 5, WHEN SHE WHEN ACUTELY DECOMPENSATED FROM FULL 5/5 STRENGTH IN ALL EXTREMITIES TO 0/5 STRENGTH IN THE DISTAL UPPER EXTREMITIES AND ENTIRE LOWER EXTREMITIES. MRI DEMONSTRATED A LARGE FLUID COLLECTION IN THE SURGICAL BED CAUSING CORD COMPRESSION, AND THE PATIENT WAS EMERGENTLY RETURNED TO THE OPERATING ROOM. THE FLUID COLLECTION HAD A THIN, OFF-WHITE APPEARANCE WITH PIECES OF THE MEDTRONIC GRAFTON PLUS DBM MIXED IN WITH IT. THERE WAS NO HEMATOMA, PUS, OR CSF (MORE TYPICAL CAUSES OF POSTOPERATIVE COLLECTIONS). WE SUSPECT THAT THE PATIENT HAD AN ALLERGIC REACTION TO ONE OF THE PROCESSING AGENTS IN BONE GRAFT (E.G. SURFACTANT OR ANTIBIOTICS), A FLUID COLLECTION RESULTED FROM THE INFLAMMATORY RESPONSE.
Patient problems: Hypersensitivity/Allergic reaction; Muscle Weakness/Atrophy; Nervous System Injury
MAUDE report 15147850 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K043048. One submission often covers many models, so check the product and lot details in each record.
- Z-0137-2027 · Aug 12, 2026 · Open, ClassifiedGrafton" DBM and Grafton Plus" DBM contain demineralized human bone tissue combined with an inert additive to yield a demineralized bone matrix (DBM) allograft product having a p
- Z-0088-2013 · Apr 20, 2012 · TerminatedGrafton DBM Matrix PLF Multiple Sizes Grafton is a human bone allograft product containing demineralized human bone tissue combined with inert additive to yield a demineralized bo
- Z-0091-2013 · Apr 20, 2012 · TerminatedGrafton DBM Orthoblend Large Defect Multiple Sizes Grafton is a human bone allograft product containing demineralized human bone tissue combined with inert additive to yield a de
- Z-0085-2013 · Apr 20, 2012 · TerminatedGrafton DBM Flex Multiple Sizes Grafton is a human bone allograft product containing demineralized human bone tissue combined with inert additive to yield a demineralized bone mat
- Z-0086-2013 · Apr 20, 2012 · TerminatedGrafton DBM A-Flex Multiple Sizes Grafton is a human bone allograft product containing demineralized human bone tissue combined with inert additive to yield a demineralized bone m
- Z-0089-2013 · Apr 20, 2012 · TerminatedGrafton DBM Matrix Strips Multiple Sizes Grafton is a human bone allograft product containing demineralized human bone tissue combined with inert additive to yield a demineralized
- Z-0094-2013 · Apr 20, 2012 · TerminatedOptimum Expanse S Multiple sizes Grafton is a human bone allograft product containing demineralized human bone tissue combined with inert additive to yield a demineralized bone ma
- Z-0087-2013 · Apr 20, 2012 · TerminatedGrafton DBM Crunch Multiple Sizes Grafton is a human bone allograft product containing demineralized human bone tissue combined with inert additive to yield a demineralized bone m
- Z-0090-2013 · Apr 20, 2012 · TerminatedGrafton DBM Orthoblend Small Defect Multiple Sizes Grafton is a human bone allograft product containing demineralized human bone tissue combined with inert additive to yield a dem
- Z-0084-2013 · Apr 20, 2012 · TerminatedGrafton DBM Gel Multiple Sizes Grafton is a human bone allograft product containing demineralized human bone tissue combined with inert additive to yield a demineralized bone matr
- Z-0093-2013 · Apr 20, 2012 · TerminatedOptimum Expanse R Grafton is a human bone allograft product containing demineralized human bone tissue combined with inert additive to yield a demineralized bone matrix (DBM) allo
- Z-0092-2013 · Apr 20, 2012 · TerminatedGrafton DBM Orthoblend Large Defect Multiple Sizes Grafton is a human bone allograft product containing demineralized human bone tissue combined with inert additive to yield a de
- Z-0083-2013 · Apr 20, 2012 · TerminatedGrafton DBM Putty Multiple Sizes Grafton is a human bone allograft product containing demineralized human bone tissue combined with inert additive to yield a demineralized bone ma
Other Filler, bone void, osteoinduction (w/o human growth factor) devices
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T45005Medtronic Sofamor Danek, Inc. · Filler, bone void, osteoinduction (w/o human growth factor)3 recalls0 reports
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T44135Medtronic Sofamor Danek, Inc. · Filler, bone void, osteoinduction (w/o human growth factor)2 recalls1 report
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T44115Medtronic Sofamor Danek, Inc. · Filler, bone void, osteoinduction (w/o human growth factor)2 recalls1 report
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T45001Medtronic Sofamor Danek, Inc. · Filler, bone void, osteoinduction (w/o human growth factor)2 recalls0 reports
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T42100Medtronic Sofamor Danek, Inc. · Filler, bone void, osteoinduction (w/o human growth factor)2 recalls0 reports
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T42210Medtronic Sofamor Danek, Inc. · Filler, bone void, osteoinduction (w/o human growth factor)2 recalls0 reports
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T43105Medtronic Sofamor Danek, Inc. · Filler, bone void, osteoinduction (w/o human growth factor)1 recall4 reports
- GRAFTON® DBM T44150INTMedtronic Sofamor Danek, Inc. · Filler, bone void, osteoinduction (w/o human growth factor)1 recall1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page