STREAMLINE™ 6495FRecalls & reported problems
Medtronic, Inc. · WIRE 6495F TEMP PACE BIP MYO 6PK 26L · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 8
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 00643169310100), received between Jul 19, 2021 and Jan 14, 2026 — classified as 1 injury, 7 malfunctions.
The most frequently reported specific device problem is “Break” (7 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break7
- Contamination /Decontamination Problem1
- Patient Device Interaction Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions7
- Non specific EKG/ECG Changes1
Recent adverse event reports
The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.
InjuryJan 14, 2026Break; Patient Device Interaction Problem
MEDTRONIC RECEIVED INFORMATION THAT AN UNKNOWN DURATION POST IMPLANT OF THIS MYOCARDIAL TEMPORARY PACING LEAD, IT WAS REPORTED THAT THE CONNECTOR PINS CONNECTED TO THE PACING CABLE HAD BROKEN. IT WAS THEN REPORTED THAT THE PATIENT REQUIRED CARDIOPULMONARY RESUSCITATION (CPR). SUBSEQUENTLY, A PERMANENT PACEMAKER WAS IMPLANTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Non specific EKG/ECG Changes
MAUDE report 24073307 ↗MalfunctionOct 29, 2024Contamination /Decontamination Problem; Contamination /Decontamination Problem
MEDTRONIC RECEIVED INFORMATION THAT PRIOR TO USE OF THIS TEMPORARY PACING WIRE, IT WAS REPORTED THAT THERE WAS A HAIR OBSERVED INSIDE THE STERILE PACKAGING. NO PATIENT INVOLVEMENT WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20556444 ↗MalfunctionJul 1, 2024Break; Break
MEDTRONIC RECEIVED INFORMATION THAT PRIOR TO USE OF THIS MYOCARDIAL TEMPORARY PACING LEAD, IT WAS REPORTED THAT THE LEAD WAS BROKEN BEFORE USE. THERE WAS NO PATIENT INVOLVEMENT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19645633 ↗MalfunctionJul 1, 2024Break; Break
MEDTRONIC RECEIVED INFORMATION THAT PRIOR TO USE OF THIS MYOCARDIAL TEMPORARY PACING LEAD, IT WAS REPORTED THAT THE LEAD WAS BROKEN BEFORE USE. THERE WAS NO PATIENT INVOLVEMENT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19645622 ↗MalfunctionJul 1, 2024Break; Break
MEDTRONIC RECEIVED INFORMATION THAT PRIOR TO USE OF THIS MYOCARDIAL TEMPORARY PACING LEAD, IT WAS REPORTED THAT THE LEAD WAS BROKEN BEFORE USE. THERE WAS NO PATIENT INVOLVEMENT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19645606 ↗MalfunctionJul 1, 2024Break; Break
MEDTRONIC RECEIVED INFORMATION THAT PRIOR TO USE OF THIS MYOCARDIAL TEMPORARY PACING LEAD, IT WAS REPORTED THAT THE LEAD WAS BROKEN BEFORE USE. THERE WAS NO PATIENT INVOLVEMENT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19645585 ↗MalfunctionJul 1, 2024Break; Break
MEDTRONIC RECEIVED INFORMATION THAT PRIOR TO USE OF THIS MYOCARDIAL TEMPORARY PACING LEAD, IT WAS REPORTED THAT THE LEAD WAS BROKEN BEFORE USE. THERE WAS NO PATIENT INVOLVEMENT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19645578 ↗MalfunctionJul 19, 2021Break; Break
MEDTRONIC RECEIVED INFORMATION THAT DURING THE INITIAL IMPLANT OF THIS TEMPORARY PACING LEAD, THE LEAD WAS INSERTED INTO THE PATIENTS CHEST WALL, AND ONE OF THE ELECTRODES BROKE OFF OF THE LEAD AND REMAINED INSIDE THE PATIENT. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12187622 ↗
Other ELECTRODE, PACEMAKER, TEMPORARY devices
- N/A 006173PC. R. Bard, Inc. · ELECTRODE, PACEMAKER, TEMPORARY161 reports
- SWAN-GANZ D200F7Edwards Lifesciences LLC · ELECTRODE, PACEMAKER, TEMPORARY1 recall0 reports
- ETHICON TPW32Ethicon, LLC · ELECTRODE, PACEMAKER, TEMPORARY1 death46 reports
- ETHICON TPW20Ethicon, LLC · ELECTRODE, PACEMAKER, TEMPORARY39 reports
- N/A 520007PC. R. Bard, Inc. · ELECTRODE, PACEMAKER, TEMPORARY33 reports
- Pacel™ 401763St. Jude Medical Cardiovascular Division · ELECTRODE, PACEMAKER, TEMPORARY21 reports
- Pacel™ 401771St. Jude Medical Cardiovascular Division · ELECTRODE, PACEMAKER, TEMPORARY1 death16 reports
- SWAN-GANZ PACING TD CATHETER D205F7Edwards Lifesciences LLC · Electrode, Pacemaker, Temporary13 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page