N/A 9735016Recalls & reported problems
Medtronic Navigation, Inc. · SUCTION 9735016 MALLEABLE STDTIP 9-FR · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00643169443518), received between Jul 1, 2024 and Apr 4, 2025 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Device Sensing Problem” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Device Sensing Problem3
- Incorrect, Inadequate or Imprecise Result or Readings1
- Unintended Application Program Shut Down1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 4, 2025Device Sensing Problem; Device Sensing Problem
MEDTRONIC RECEIVED INFORMATION REGARDING A NAVIGATION SYSTEM BEING USED DURING A FUNCTIONAL ENDOSCOPIC SINUS SURGERY (FESS) PROCEDURE. IT WAS REPORTED THAT THE PATIENT TRACKER AND INSTRUMENT TRACKER WERE OPERATING PERFECT WITH ALL INSTRUMENTS EXCEPT THE 70 DEGREE SUCKER WOULDN'T VERIFY. ONCE PLUGGED IN, THE MALLEABLE SUCTION WOULDN'T APPEAR ON THE NAVIGATION SCREEN AND DID NOT APPEAR IN THE TRACKER/EMITTER DETAILS (BOTTOM RIGHT CORNER OF SCREEN). MOVING THE MALLEABLE SUCTION ALL AROUND THE PATIENT HEAD, IT APPEARED BRIEFLY IN RED AT EXTREMITIES OF THE MAGNETIC FIELD PRODUCED BY THE SIDE EMITTER. THE MALLEABLE SUCTION WAS PLUGGED INTO OTHER AXIEM PORTS WITH SAME BEHAVIOR CONTINUING. THE MALLEABLE SUCTION WAS ABANDONED AND COMPETED THE CASE WITH A METAL INSTRUMENT SET. THIS ISSUE CAUSED LESS THAN 1 HOUR SURGICAL DELAY. THERE WAS NO REPORTED IMPACT ON PATIENT OUTCOME.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21777915 ↗MalfunctionMar 10, 2025Device Sensing Problem; Device Sensing Problem
MEDTRONIC RECEIVED INFORMATION REGARDING A NAVIGATION SYSTEM BEING USED DURING A FUNCTIONAL ENDOSCOPIC SINUS SURGERY (FESS) PROCEDURE. IT WAS REPORTED THAT THE MALLEABLE SUCTION WAS PLUGGED INTO AN ELECTROMAGNETIC NAVIGATION INTERFACE UNIT (AXIEM) PORT AND THE SYSTEM WAS UNABLE TO SEE SUCTION IN THE FIELD OF VIEW. A REPLACEMENT SUCTION WAS OPENED WITH NO ISSUE AND PROCEDURE CONTINUED. THERE WAS NO DELAY. THERE WAS NO IMPACT ON PATIENT OUTCOME.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21566363 ↗MalfunctionNov 5, 2024Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
ADDITIONAL INFORMATION WAS RECEIVED. THE SITE NURSES PLUGGED THE INSTRUMENT INTO THE NAVIGATION SYSTEM, IT REGISTERED AS IT SHOULD BUT WHEN THE SURGEON TRIED TO VERIFY THE POINTS ON THE PATIENT, IT FAILED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20609088 ↗MalfunctionJul 1, 2024Device Sensing Problem; Unintended Application Program Shut Down; Device Sensing Problem; Unintended Application Program Shut Down
ADDITIONAL INFORMATION WAS RECEIVED. THE PROCEDURE BEING PERFORMED WAS A FUNCTIONAL ENDOSCOPIC SINUS SURGERY (FESS), THERE WAS A LESS THAN 30 MINUTE SURGICAL DELAY, AND THERE WAS NO IMPACT TO THE PATIENT'S OUTCOME.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19646721 ↗
Other Ear, Nose, and Throat Stereotaxic Instrument devices
- TruDi NAV Suction TDNS000ZAcclarent, Inc. · Ear, Nose, and Throat Stereotaxic Instrument1 recall61 reports
- Scopis 8000-021-002Stryker Leibinger GmbH & Co. KG · Ear, Nose, and Throat Stereotaxic Instrument1 recall19 reports
- TruDi™ Navigation System 1Biosense Webster (Israel) Ltd. · Ear, Nose, and Throat Stereotaxic Instrument1 recall14 reports
- FUSION Compact ™ 9735602Medtronic Navigation, Inc. · Ear, Nose, and Throat Stereotaxic Instrument64 reports
- StealthStation 9735762Medtronic Navigation, Inc. · Ear, Nose, and Throat Stereotaxic Instrument1 recall0 reports
- Medtronic Navigation 9735762Medtronic Navigation, Inc. · Ear, Nose, and Throat Stereotaxic Instrument1 recall0 reports
- StealthStation Cranial Software 9735762Medtronic Navigation, Inc. · Ear, Nose, and Throat Stereotaxic Instrument1 recall0 reports
- Scopis ENT 8000-020-002Stryker Leibinger GmbH & Co. KG · Ear, Nose, and Throat Stereotaxic Instrument33 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page