ZINGER® MEDIUM ZNGRMS180HSRecalls & reported problems
Medtronic, Inc. · GDWR ZNGRMS180HS ZINGERMS 5PK 180 ST HY · Class 2
All models of ZINGER MEDIUM (5)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00643169452657), received between Mar 9, 2018 and Feb 8, 2024 — classified as 1 death, 2 malfunctions.
The most frequently reported specific device problem is “Material Deformation” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Material Deformation2
- Component or Accessory Incompatibility1
- Detachment of Device or Device Component1
- Entrapment of Device1
- Material Integrity Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- Death1
- Intimal Dissection1
- Thrombus1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 8, 2024Entrapment of Device; Material Deformation; Material Integrity Problem; Entrapment of Device; Material Deformation; Material Integrity Problem
AN ATTEMPT WAS MADE TO USE TWO ZINGER GUIDEWIRES AND ONE LEFT VENTRICULAR (LV) LEAD. NO CALCIFICATION OR STENOSIS AND LITTLE TORTUOS ITY WAS NOTED. THE GUIDEWIRES WERE BEING USED FOR LEAD PLACEMENT USING THE OVER THE WIRE (OTW) TECHNIQUE. THE ZINGER DEVICES WERE INSPECTED BEFORE USE WITH NO ISSUES NOTED. THERE WERE NO DIFFICULTIES NOTED WHEN LOADING THE GUIDEWIRES. THE SOFT TIP OF THE GUIDEWIRES WERE SLIGHTLY CURVED TO PROBE THE VEIN. THE FIRST ZINGER GUIDEWIRE DID NOT PASS THROUGH THE CELL OF A STENT OR A TIGHT CALCIFIED LESION DURING DELIVERY. RESISTANCE WAS NOT NOTED WHILE ADVANCING THE FIRST ZINGER DEVICE. IT WAS REPORTED THAT AFTER THE PLACEMENT AND FIXATION OF THE LV LEAD IT WAS NOT POSSIBLE TO REMOVE THE ZINGER GUIDEWIRE. THE LV LEAD WAS PLACED TO THE POSTEROLATERAL POSITION AND AFTER THE FIXATION OF THE LEAD THE ZINGER GUIDEWIRE COULD NOT BE REMOVED. THE LEAD WAS REMOVED WITH THE GUIDEWIRE AND THE GUIDEWIRE WAS STULL STUCK IN THE LEAD. A DIFFERENT LV LEAD WAS USED WITH ANOTHER ZINGER GUIDEWIRE. THIS ZINGER GUIDEWIRE HAD A HIGH RESISTANCE AFTER SOME EXPLORATORY MOVEMENTS, AND WAS REMOVED. A NON-MEDTRONIC GUIDEWIRE WAS USED INSTEAD AND THE REPLACEMENT LV LEAD WAS POSITIONED A
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18667852 ↗MalfunctionMar 9, 2021Detachment of Device or Device Component; Detachment of Device or Device Component
DURING A PROCEDURE AN ATTEMPT WAS MADE TO USE ONE ZINGER GUIDEWIRE AND ONE ATTAIN PERFORMA LEAD TO TREAT A MILDLY TORTUOUS AND NON-CALCIFIED LESION IN THE CANNULATION OF LATERAL VEINS OF CORONARY SINUS. THE GUIDEWIRE WAS INSPECTED AND PREPPED PER IFU WITH NO ISSUES NOTED. THE WIRE TIP WAS NOT FORMED. THE LESION WAS NOT PREDILATED. THERE WERE NO DIFFICULTIES NOTED WHEN LOADING THE LEAD ONTO THE GUIDEWIRE. THE DEVICE DID NOT PASS THROUGH A PREVIOUSLY DEPLOYED STENT. RESISTANCE WAS EXPERIENCED DURING INSERTION AND ADVANCING THE DEVICE. EXCESSIVE FORCE WAS NOT USED. THE GUIDE WIRE WAS USED DURING LV LEAD PLACEMENT. THE WIRE WAS PLACED AT THE TARGET VEIN, LEAD FOLLOWED THE WIRE AND IMMEDIATELY IT WAS NOT POSSIBLE TO MOVE THE WIRE IN THE LEAD. IT OCCURRED AT THE BEGINNING OF PROCEDURE. IT WAS THE FIRST PLACEMENT AND THE FIRST USAGE. BOTH PRODUCTS WERE REMOVED AND DAMAGE OF THE WIRE WAS OBSERVED. IT WAS REPORTED THAT THE WIRE WAS KINKED WHEN THE WIRE WAS IN PATIENT. RESISTANCE WAS NOTED DURING REMOVAL OF THE DEVICE. IT WAS STATED THAT IT WAS IMPOSSIBLE TO REMOVE THE WIRE FROM THE LEAD. EXCESSIVE FORCE WAS NOT USED. THE GUIDEWIRE REMAINED IN THE LEAD. NO PATIENT INJURY WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11445711 ↗DeathMar 9, 2018Component or Accessory Incompatibility; Material Deformation; Component or Accessory Incompatibility; Material Deformation
THE PHYSICIAN INTENDED TO USE A ZINGER GUIDE WIRE IN A PROCEDURE TO TREAT A MODERATELY TORTUOUS, NON-CALCIFIED LESION IN THE PROXIMAL - MID RIGHT CORONARY ARTERY (RCA) WITH 80% PROXIMAL STENOSIS AND 99% MID STENOSIS. THE PATIENT HAD NO PREVIOUS ANTERIOR PCI. THE PATIENT HAD NO PREVIOUS STENTS, OR OTHER PRODUCTS IMPLANTED. THE PATIENT HAD A CRITICAL OBSTRUCTION IN THE RIGHT CORONARY VESSEL CAUSED BY ATHEROMA. THERE WAS NO DAMAGE NOTED TO THE DEVICE PACKAGING. THE DEVICE WAS REMOVED FROM THE PACKAGING PER IFU WITH NO ISSUES. THE DEVICE WAS INSPECTED WITH NO ISSUES. THE DEVICE WAS PREPPED PER IFU WITH NO ISSUES. THE WIRE TIP WAS NOT FORMED BY THE PHYSICIAN. THE LESION WAS NOT PRE-DILATED. THE DEVICE DID NOT PASS THROUGH A PREVIOUSLY DEPLOYED STENT. RESISTANCE WAS ENCOUNTERED WHEN ADVANCING THE DEVICE AND EXCESSIVE FORCE WAS NOT USED. IT IS REPORTED THAT THERE WAS LOW SUPPORT, POOR STEERABILITY/POOR NAVIGABILITY DURING DELIVERY TO THE TARGET LESION AND DEFORMATION OF THE GUIDEWIRE. OTHER DEVICES WERE IN USE WITH THE WIRE WHEN THE ISSUE OCCURRED, A LA6JR40 LAUNCHER GUIDE CATHETER, A PYTON KIT AND A 6F INTRODUCER (061102A). THERE IS NO EVIDENCE ABOUT THE USE OF AN ANGIOPLASTIC BALLOON FO
Patient problems: Death; Intimal Dissection; Thrombus
MAUDE report 7328315 ↗
Other WIRE, GUIDE, CATHETER devices
- HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL II 1009664Abbott Vascular Inc. · WIRE, GUIDE, CATHETER321 reports
- SYNCHRO 14 M00313010Stryker Corporation · WIRE, GUIDE, CATHETER2 recalls220 reports
- PressureWire™ C12059Lightlab Imaging, Inc. · WIRE, GUIDE, CATHETER1 death296 reports
- SYNCHRO 2 M00326410Stryker Corporation · WIRE, GUIDE, CATHETER2 recalls155 reports
- ENROUTE .014" Guidewire 11686-01Silk Road Medical, Inc. · Wire, Guide, Catheter2 deaths228 reports
- ARROW IPN035915Teleflex Incorporated · WIRE, GUIDE, CATHETER217 reports
- OmniWire Pressure guide wire 89185Philips Image Guided Therapy Corporation · Wire, Guide, Catheter1 recall1 death160 reports
- ARROW IPN055780Teleflex Incorporated · Wire, guide, catheter4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page