Medtronic, Inc. · ICD-DR DDBC3D4 EVERA S US DF4 · Class 3 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
13
Deaths reported
0
Injuries reported
7
Recalls naming it
1

Summary

The FDA's MAUDE database contains 13 adverse event reports that list this exact device (DI 00643169530294), received between Feb 9, 2017 and Sep 14, 2026 — classified as 7 injuries, 6 malfunctions.

The most frequently reported specific device problem is “Device Sensing Problem” (2 reports).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Feb 3, 2021Open, Classified

    A small percentage of implanted cardiac devices, from a well-defined subset, may experience a shortened Recommended Replacement Time (RRT) to End of Service (EOS) interval following an earlier-than-expected RRT observation

    Z-1305-2021 · Root cause: Device Design · FDA record ↗

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Device Sensing Problem2
  • Inappropriate/Inadequate Shock/Stimulation2
  • Pacing Problem2
  • Appropriate Device Problem Term/Code Not Available1
  • Electrical /Electronic Property Problem1
  • Failure to Interrogate1
  • Insufficient Device Problem Information1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • No Known Impact Or Consequence To Patient3
  • Shock from Patient Lead(s)2
  • Syncope/Fainting2
  • Unspecified Infection2
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Dyspnea1
  • Fall1

Recent adverse event reports

The 13 most recent of 13 reports, in the reporter's own words as published by the FDA.

  • InjurySep 14, 2026Device Sensing Problem

    It was reported by the patient that their Implantable Cardioverter Defibrillator (ICD) "went off during the night" and they "felt funny" and was "coming in and out of it". The patient also stated that they "fainted and fell" and remembered  "coming back" and "gasping for air". The ICD remains in use. No further patient complications have been reported as a result of this event.

    Patient problems: Dyspnea; Fall; Shock from Patient Lead(s); Syncope/Fainting

    MAUDE report 50757021 ↗
  • InjuryDec 29, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS FURTHER REPORTED THAT THE ICD WAS EXPLANTED.

    Patient problems: Unspecified Infection

    MAUDE report 23908361 ↗
  • MalfunctionNov 6, 2024Pacing Problem; Device Sensing Problem; Pacing Problem; Device Sensing Problem

    IT WAS REPORTED THAT THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) DELIVERED INAPPROPRIATE ANTI-TACHYCARDIA PACING (ATP) THERAPY FOR SUPRA VENTRICULAR TACHYCARDIA (SVT) WHICH THE DEVICE DETECTED AS VENTRICULAR TACHYCARDIA (VT). THE DEVICE REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20624806 ↗
  • InjuryAug 8, 2024Inappropriate/Inadequate Shock/Stimulation; Inappropriate/Inadequate Shock/Stimulation

    IT WAS REPORTED BY THE PATIENT THAT THEY HAD RECEIVED A SHOCK FROM THEIR IMPLANTED DEVICE, AND HAD PASSED OUT THE DAY PRIOR. THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) REMAINS IN USE. IT WAS FURTHER REPORTED THAT THE REMOTE MONITOR DID NOW SHOW INFORMATION OF TRANSMISSION THAT WAS SENT OUT BY THE PATIENT. THE PATIENT WAS INFORMED THAT IT WOULD AUTOMATICALLY DOWNLOAD AND SENT TO THE CLINIC. THE PATIENT MANAGEMENT DATABASE CONFIRMED THAT THE REMOTE MONITOR DID NOT HAVE ANY SUCCESSFUL AUTOMATIC TRANSMISSIONS SINCE THE DATE OF THE CALL. THE PATIENT WAS REFERRED TO A DEVICE SPECIALIST. THE MONITOR REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Syncope/Fainting

    MAUDE report 19942707 ↗
  • MalfunctionMay 21, 2021Pacing Problem; Pacing Problem

    THE PATIENT'S SPOUSE REPORTED THAT WHILE THE PATIENT WAS IN THE HOSPITAL, THE PATIENT WAS NOTED TO HAVE A HEART RATE THAT WAS LOWER THAT THE PROGRAMMED RATE. THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) WAS INDICATED TO NOT BE "FIRING." THE ICD REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 11864718 ↗
  • InjuryApr 22, 2021Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    IT WAS FURTHER REPORTED THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) WAS PROPHYLACTICALLY REPLACED DUE TO REQUIRING AN UPGRADE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11708207 ↗
  • MalfunctionDec 17, 2020Failure to Interrogate; Failure to Interrogate

    IT WAS REPORTED THAT THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) COULD NOT BE INTERROGATED AFTER SEVERAL ATTEMPTS WITH MULTIPLE PROGRAMMERS. THE DEVICE REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11028610 ↗
  • InjuryOct 8, 2018Insufficient Device Problem Information; Insufficient Device Problem Information

    IT WAS REPORTED THAT THE PATIENT¿S RIGHT VENTRICULAR (RV) LEAD TRIGGERED AN ALERT FOR A PACING IMPEDANCE READING OF ZERO. IN ADDITION, THE RV LEAD WAS EXHIBITING SENSING INTEGRITY COUNTER (SIC) THAT STARTED ABRUPTLY AND INCREASED DAILY. THE RV LEAD WAS CAPPED AND REPLACED. IT WAS FURTHER REPORTED THAT THE PHYSICIAN THOUGHT THE IMPEDANCE AND SIC ISSUES COULD BE RELATED TO THE PATIENT¿S IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD). THE ICD WAS EXPLANTED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7945095 ↗
  • InjuryJun 13, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THE PATIENT PRESENTED TO THE URGENT CARE WITH A FEVER, AN INCREASE IN POCKET PAIN AND SWELLING. WOUND CULTURES AND BLOOD TESTS WERE POSITIVE FOR STAPHYLOCOCCUS AUREUS. IT WAS ALSO REPORTED THE PATIENT DEVELOPED AN INFECTION OF THE LEFT SIDE OF THE POCKET. THE PATIENT WAS TREATED WITH ORAL AND INTRAVENOUS ANTIBIOTICS AND THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR SYSTEM WAS REMOVED. THE PATIENT IS A PARTICIPANT IN THE PRODUCT SURVEILLANCE REGISTRY CLINICAL STUDY. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Fever; Pain; Staphylococcus Aureus; Swelling; Unspecified Infection

    MAUDE report 7597562 ↗
  • MalfunctionApr 10, 2018Electrical /Electronic Property Problem; Electrical /Electronic Property Problem

    IT WAS REPORTED THAT AN IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) WAS PREPARED FOR POTENTIAL IMPLANT, HOWEVER THERE WAS A GREY BAR FOR BATTERY LONGEVITY. THE DEVICE WAS RECHECKED SIX DAYS LATER AND THE GRAY BAR CONTINUED. THE DEVICE WAS NEVER IMPLANTED. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 7417028 ↗
  • InjuryOct 6, 2017Inappropriate/Inadequate Shock/Stimulation; Inappropriate/Inadequate Shock/Stimulation

    IT WAS REPORTED THAT THE PATIENT PRESENTED AT THE EMERGENCY ROOM DUE TO SHOCKS RECEIVED FROM THEIR IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD). IT WAS NOTED THAT THERE WERE ELEVEN HIGH RATE NON SUSTAINED EPISODES, AND OVER ONE HUNDRED AND THIRTY ONE NON-SUSTAINED VENTRICULAR TACHYCARDIA EPISODES. AS WELL, THE PATIENT'S RIGHT ATRIAL (RA) LEAD EXHIBITED FAR FIELD R-WAVE (FFRW). FOLLOW UP WAS CONDUCTED TO NO AVAIL. THE DEVICE IS STILL IN USE. THE LEAD IS STILL IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Shock from Patient Lead(s)

    MAUDE report 6920244 ↗
  • MalfunctionAug 9, 2017Migration or Expulsion of Device; Migration or Expulsion of Device

    IT WAS REPORTED BY THE PATIENT THAT THEIR IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) "LOOKED WEIRD; FELT LIKE IT HAD MOVED." FOLLOW UP WAS CONDUCTED TO NO AVAIL. THE DEVICE IS STILL IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6781849 ↗
  • MalfunctionFeb 9, 2017Mechanical Problem; Mechanical Problem

    IT WAS REPORTED THAT DURING A GENERATOR CHANGE WITH A COMPETITOR LEAD THE LEAD WOULD NOT SEAT PROPERLY IN THE DEVICE HEADER AND FRICTION WAS REPORTED. THE LEAD WAS REPORTED TO BE SEATED ONCE OR TWICE HOWEVER THE SET SCREW APPEARED TO PUSH THE LEAD BACK. THE DEVICE WAS NOT USED AND A DIFFERENT IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) WAS IMPLANTED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6321075 ↗

Other Implantable cardioverter defibrillator (non-CRT) devices

All Implantable cardioverter defibrillator (non-CRT) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page