HANCOCK® II T510C27 (UDI 00643169594456)Recalls & reported problems
Medtronic, Inc. · VLV T510C27 HKII MIT CINCH NNA US PEEK · Class 3 · Implant
All models of HANCOCK II (43)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 1
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00643169594456), received between Jan 23, 2019 and Apr 22, 2020 — classified as 1 death, 1 injury.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (2 reports).
4 other recalls cover devices cleared under the same FDA submission (P980043); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Insufficient Device Problem Information2
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Death1
- Exsanguination1
- No Information1
- No Known Impact Or Consequence To Patient1
- Rupture1
- Tissue Damage1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
DeathApr 22, 2020Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT THIS PATIENT UNDERWENT MITRAL VALVE REPLACEMENT DUE TO SEVERE MITRAL STENOSIS SECONDARY TO CALCIFICATION, AS WELL AS MODERATE MITRAL REGURGITATION. IT WAS REPORTED THAT THE PATIENT'S RIGHT ATRIUM WAS "VERY THIN" AND DILATED IN ALL CAVITIES. IT WAS ALSO REPORTED THAT THE TISSUE ON THE ATRIOVENTRICULAR GROOVE WAS POOR, WHICH THE SURGEON REPORTED WAS A SIGN OF CHRONIC INFLAMMATION. THE VALVE WAS SUCCESSFULLY IMPLANTED WITH NO REGURGITATION OR BLEEDING NOTED. FOLLOWING MITRAL VALVE REPLACEMENT, PRIOR TO DISCONTINUING CARDIOPULMONARY BYPASS (CPB), THE RIGHT VENTRICLE BECAME DILATED AND THE PULMONARY ARTERY WAS "TENSE". A PULMONARY SUMP WAS IMPLANTED WHICH WAS REPORTED TO DECOMPRESS THE HEART. TEMPORARY PACING WIRES WERE INSERTED IN THE LEFT APPENDAGE. WHILE ATTEMPTING TO REMOVE THIS PATIENT FROM CARDIOPULMONARY BYPASS (CPB), BLEEDING WAS NOTED BEHIND THE HEART. IT WAS REPORTED THAT THE BLEEDING WAS DETERMINED TO BE A RESULT OF SPONTANEOUS RUPTURE OF THE CRUX OF THE HEART SECONDARY TO DISTENTION OF THE HEART ONCE THE HEART HAD STARTED BEATING AGAIN. THE RUPTURE WAS ATTEMPTED TO BE REPAIRED FOR SEVERAL HOURS. ULTIMATELY THE PATIENT EXPIRED IN THE OPERAT
Patient problems: Death; Exsanguination; Rupture; Tissue Damage
MAUDE report 9985440 ↗InjuryJan 23, 2019Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT IMMEDIATELY POST IMPLANT OF THIS MITRAL BIOPROSTHETIC VALVE, THE VALVE WAS EXPLANTED AND REPLACED WITH A VALVE OF THE SAME SIZE AND MODEL. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: No Information; No Known Impact Or Consequence To Patient
MAUDE report 8270840 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P980043. One submission often covers many models, so check the product and lot details in each record.
- Z-1884-2019 · May 21, 2019 · TerminatedHancock II T510 Bioprosthesis, Mitral, REF T510C27 - Product Usage: Replacement of malfunctioning native or prosthetic aortic and/or mitral valves.
- Z-1883-2019 · May 21, 2019 · TerminatedHancock II T510 Bioprosthesis, Mitral, REF T510C27 - Product Usage: Replacement of malfunctioning native or prosthetic aortic and/or mitral valves.
- Z-1882-2019 · May 21, 2019 · TerminatedHancock II T510 Bioprosthesis, Mitral, REF T505U227 - Product Usage: Replacement of malfunctioning native or prosthetic aortic and/or mitral valves.
- Z-1226-2009 · Jan 26, 2009 · TerminatedHancock II Bioprostheses with Cinch, Heart Valve, Model # T505 & T510; Catalog #s T505C2501, T505C2101, T505U25ID , T505C2301, T505C2301, T505C2501, T505C2101, T510C29ID, T510C25ID
Other replacement Heart-valve devices
- CARPENTIER-EDWARDS PERIMOUNT MAGNA EASE PERICARDIAL BIOPROSTHESIS - AORTIC 3300TFXEdwards Lifesciences LLC · replacement Heart-valve4 deaths671 reports
- CARPENTIER-EDWARDS PERIMOUNT MAGNA EASE PERICARDIAL BIOPROSTHESIS - AORTIC 3300TFXEdwards Lifesciences LLC · replacement Heart-valve1 death656 reports
- CARPENTIER-EDWARDS PERIMOUNT MAGNA EASE PERICARDIAL BIOPROSTHESIS - AORTIC 3300TFXEdwards Lifesciences LLC · replacement Heart-valve5 deaths533 reports
- CARPENTIER-EDWARDS PERIMOUNT MAGNA MITRAL EASE PERICARDIAL BIOPROSTHESIS 7300TFXEdwards Lifesciences LLC · replacement Heart-valve1 death425 reports
- CARPENTIER-EDWARDS PERIMOUNT MAGNA MITRAL EASE PERICARDIAL BIOPROSTHESIS 7300TFXEdwards Lifesciences LLC · replacement Heart-valve1 death391 reports
- CARPENTIER-EDWARDS PERIMOUNT MAGNA MITRAL EASE PERICARDIAL BIOPROSTHESIS 7300TFXEdwards Lifesciences LLC · replacement Heart-valve1 death290 reports
- CARPENTIER-EDWARDS PERIMOUNT MAGNA EASE PERICARDIAL BIOPROSTHESIS - AORTIC 3300TFXEdwards Lifesciences LLC · replacement Heart-valve260 reports
- CARPENTIER-EDWARDS PERIMOUNT MAGNA MITRAL EASE PERICARDIAL BIOPROSTHESIS 7300TFXEdwards Lifesciences LLC · replacement Heart-valve2 deaths229 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page