CD HORIZON® SOLERA® Spinal System 651003035Recalls & reported problems

Medtronic Sofamor Danek, Inc. · ROD 651003035 5.5 CCM CAPPED ROD 35MM · Class 2 · Implant

All models of CD HORIZON SOLERA Spinal System (34)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00643169747975), received between Jun 2, 2024 and Jun 2, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Malposition of Device1
  • Mechanical Jam1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 2, 2024Break; Malposition of Device; Mechanical Jam; Break; Malposition of Device; Mechanical Jam

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT IMPLANTED WITH CAPPED ROD HAVING L4/5 POSTERIOR LUMBAR INTERBODY FUSION THERAPY FOR SPINAL INSTABILITY. IT WAS REPORTED THAT THE CAPPED END OF THE ROD BECAME LODGED IN THE TULIP OF THE SCREW HEAD WHILE INSERTING THE SET SCREW. SET SCREW WAS GROUND DOWN ONTO THE CAPPED END AND GROUND OFF SEVERAL METAL SHARDS. ROD BECAME STUCK INTO THE TULIP AND HAD TO BE PULLED OUT FIRMLY WITH A ROD HOLDER. SURGEON REFLECTED THAT THEY SHOULD HAVE CONFIRMED THEIR ROD PLACEMENT BEFORE PUTTING IN SET SCREWS. THERE WERE NO PATIENT SYMPTOMS REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT. ADDITIONAL INFORMATION RECEIVED THAT THE CAPPED END OF THE ROD WAS GROUND DOWN AND METAL SHARDS WERE CREATED WHILE WITHIN THE PATIENT. METAL SHARDS WERE ALL REMOVED IMMEDIATELY AS IT HAPPENED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19444621 ↗

Other Orthopedic stereotaxic instrument devices

All Orthopedic stereotaxic instrument devices →