CD HORIZON® SOLERA® VOYAGER™ Spinal System 55750017535Recalls & reported problems
Medtronic Sofamor Danek, Inc. · SCREW 55750017535 5.5VOYAGER STMAS7.5X35 · Class 1 · Implant
All models of CD HORIZON SOLERA VOYAGER Spinal System (60)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00643169783898), received between May 11, 2020 and Mar 27, 2024 — classified as 2 injuries, 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Break1
- Loosening of Implant Not Related to Bone-Ingrowth1
Patient problems
- Foreign Body Reaction1
- Hernia1
- No Known Impact Or Consequence To Patient1
- Post Operative Wound Infection1
- Undesired Nerve Stimulation1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryMar 27, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAD OLIF (L2/3/4) AND T10~SAI FIXATION AND L5/SPLIF FROM THE REAR. IT WAS REPORTED THAT THE LOOSE SCREW CAUSED INFECTION IN PATIENT. ALTHOUGH FIXATION WAS PERFORMED FROM T10 TO SAI, A WOUND APPEARED ON THE SKIN OF THE RIGHT SAI AREA AND PUS ALSO CAME OUT. WHEN IT WAS DEPLOYED, THE TISSUE FROM THE SKIN SURFACE TO THE SCREW HEAD CONTINUED TO HAVE DARK GRANULATION, AND THERE WAS PUS IN THE SURROUNDING AREA. THE SET SCREW IN THE SCREW HEAD WAS LOOSE ENOUGH THAT IT COULD BE REMOVED WITH FORCEPS, AND THE SURROUNDING TISSUE SHOWED DARK SPOTS AND BLACK POWDERY MATTER. THE SCREW THAT HAD BEEN INSERTED HAD A CLEAR ZONE ON THE IMAGE, BUT IT WAS REASONABLY EFFECTIVE. THE RIGHT SIDE WAS IN A NOTICEABLE CONDITION, BUT WHEN CHECKED THE LEFT SIDE, IT WAS IN THE SAME CONDITION. A REVISION SURGERY WAS PERFORMED DUE TO SUSPICION OF METALLOSIS DUE TO WEAR PARTICLES OF THE IMPLANT, BLACK GRANULATION ON THE SOFT TISSUES, WOUNDS ON THE WOUND SURFACE AND PUS IN THE VICINITY. IMPLANT WAS CUT AND REMOVED. INITIAL SURGERY WAS DONE ON (B)(6) 2023. ADDITIONAL INFORMATION RECEIVED. THE SET SCREWS WERE L
Patient problems: Foreign Body Reaction; Post Operative Wound Infection
MAUDE report 18984846 ↗InjurySep 28, 2023Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth
INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING L5/S1 TLIF. IT WAS REPORTED THAT THE PATIENT UNDERWENT TLIF ON (B)(6) 2023 AT L5/S1, AND THE CY CAGE CONTRACTED IN AUGUST CAUSING THE GRAFTED BONE TO COMPRESS THE NERVE. THE GRAFTED BONE WAS COMING OUT LIKE A HERNIA AND PRESSING ON THE NERVE, SO THE CAGE WAS REMOVED AND REPLACED WITH MILESTONE IN AN ADDITIONAL SURGERY PERFORMED ON (B)(6) 2023. THE SCREWS WERE LOOSE AND THE PROCEDURE WAS COMPLETED BY REPLACING THE LOOSE SCREWS. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.
Patient problems: Hernia; Undesired Nerve Stimulation
MAUDE report 17832032 ↗MalfunctionMay 11, 2020Break; Break
IT WAS REPORTED THAT THE PATIENT UNDERWENT SCREW REMOVAL SURGERY AT L5/S DUE TO SPINAL CANAL STENOSIS. INTRA-OP, AT THE TIME OF REMOVING THE LEFT S1 SCREW, BREAKAGE WAS CONFIRMED AT THE SCREW HEAD AND SCREW SHAFT BY THE SAGITTAL IMAGE IN THE PROCESS OF INSERTING REMOVAL DRIVER INTO THE SCREW HEAD. ALTHOUGH THE SCREW DID NOT APPEAR TO BE BROKEN ON THE IMAGE. FRAGMENTS OF IMPLANT ARE REMAINING IN THE PATIENT. THE SURGEON DECIDED THAT THE FRAGMENT OF THE IMPLANT COULD NOT BE REMOVED, AND WOUND CLOSURE WAS PERFORMED. EXPLANATION WAS PERFORMED TO THE PATIENT, AND THE BROKEN PART WILL BE REMOVED ON ANOTHER DAY IF REQUESTED. THERE WAS NO DELAY IN OVERALL PROCEDURE TIME AND NO PATIENT SYMPTOMS OR COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10041786 ↗
Other INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT devices
- NA 511.701Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT2,164 reports
- SmartLife 7126-120-000Stryker Corporation · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT1,065 reports
- NA 05.001.224Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT987 reports
- NA 05.001.206Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT632 reports
- NA 532.021Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT521 reports
- NA 2570-04-501Depuy (Ireland) · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT500 reports
- NA 532.110Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT433 reports
- NA 05.001.223Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT397 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page