CD HORIZON® SOLERA® VOYAGER™ Spinal System 54850047545Recalls & reported problems
Medtronic Sofamor Danek, Inc. · SCREW 54850047545 4.75VOYAGER ATS 7.5X45 · Class 2 · Implant
All models of CD HORIZON SOLERA VOYAGER Spinal System (60)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00643169787506), received between Mar 12, 2025 and Mar 12, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Material Deformation” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Material Deformation1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 12, 2025Material Deformation; Material Deformation
INFORMATION WAS RECEIVED FROM A HEALTHCARE PROFESSIONAL VIA MANUFACTURER REPRESENTATIVE REGARDING A SCREW USED IN ROBOTIC GUIDED PEDICLE SCREW PLACEMENT LUMBAR 5 THERAPY FOR STENOSIS. IT WAS REPORTED THAT THE PATIENT WAS FINE BUT WHEN THE SURGEON TRIED SNAPPING OFF THE VOYAGER 4.75 PERC SET SCREW IT WOULDN¿T BREAK OFF. THE HANDLE WOULD ¿SKIP¿ AND NOT BREAK OFF. IT IS THOUGHT THAT THE SCREW MAYBE DEFECTIVE AND MAYBE THE SETSCREW SPLAYED THE HEAD OF THE SCREW. IT APPEARED TO BE SLIGHTLY SPLAYED. ABOUT 3 DIFFERENT SETSCREWS WERE TRIED AND THEN A LONGER ROD. IT WAS ALSO TRIED TO RAISE L4 TO MAKE L4 AND 5 NEARLY IDENTICAL IN HEIGHT. THEY HAD TRIED BACKING THAT SCREW OFF A BIT EVEN THOUGH SCREW WAS NOT BURIED IN BONE, IT HAD FULL RANGE OF MOTION. FINALLY THEY REPLACED THE SCREW WITH ANTHER 7.5X45 AND IT WORKED. NO ADDITIONAL SURGERY WAS PERFORMED. NO PATIENT SYMPTOMS WERE REPORTED. NO FURTHER COMPLICATIONS WERE REPORTED/ANTICIPATED. ADDITIONAL INFORMATION WAS RECEIVED. IT WAS REPORTED THAT THERE WERE NO OTHER PRODUCT MALFUNCTIONS IN THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21581043 ↗
Other Thoracolumbosacral pedicle screw system devices
- EXPEDIUM VERSE 199721000Medos International Sàrl · Orthosis, spinal pedicle fixation, for degenerative disc disease387 reports
- Sequoia® 3301-1Zimmer Spine, Inc. · Orthosis, spinal pedicle fixation, for degenerative disc disease184 reports
- CD HORIZON® Spinal System 8590855Medtronic Sofamor Danek, Inc. · Orthosis, spinal pedicle fixation, for degenerative disc disease179 reports
- Vitality® 07.02011.001Biomet Spine LLC · Orthosis, spinal pedicle fixation, for degenerative disc disease3 recalls0 reports
- EXPEDIUM VERSE 199721001SMedos International Sàrl · Thoracolumbosacral pedicle screw system124 reports
- LineSider LS-N6SA7550Integrity Implants Inc. · Thoracolumbosacral Pedicle Screw System2 recalls1 report
- LineSider LS-N6SA6545Integrity Implants Inc. · Thoracolumbosacral Pedicle Screw System2 recalls0 reports
- EXPEDIUM VERSE 199721000SMedos International Sàrl · Thoracolumbosacral pedicle screw system97 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page