Navigated INFINITY™ Occipitocervical Upper Thoracic System NAVG3606010Recalls & reported problems
Medtronic Sofamor Danek, Inc. · DRILL BIT NAVG3606010 NAVIGATED · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00643169799936), received between Jul 6, 2020 and Dec 23, 2020 — classified as 2 injuries.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
- Dull, Blunt1
Patient problems
- Foreign Body In Patient1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryDec 23, 2020Dull, Blunt; Dull, Blunt
INFORMATION WAS RECEIVED FROM A HEALTHCARE PROVIDER VIA MANUFACTURER REPRESENTATIVE REGARDING A PATIENT WITH C1 <(>&<)> C2 FRACTURE FOR FUSION. IT WAS REPORTED THAT THE SPINOUS PROCESS CLAMP WAS NOT STABLE WHEN CLAMPED ON THE C2 SPINOUS PROCESS DUE TO THE DRILL BIT <(>&<)> THE TAP NOT ADVANCING IN THE BONE. THE PHYSICIAN HAD TO PUSH HARD TO GET THEM TO ENGAGE AND THEREFORE THE ANATOMY SHIFTED. THE AMOUNT OF FORCE APPLIED TO GET THE TAP TO ENGAGE WAS WHAT LED TO THE MISALIGNMENT AND LOSS OF FIDELITY. A C2 SCREW WAS PLACED DIRECTLY IN THE VERTEBRAL ARTERY AND THE PATIENT WAS TAKEN TO IR AFTER SURGERY TO CONFIRM NO FURTHER ACTION WAS NEEDED. THERE WERE NO PATIENT SYMPTOMS OR COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. ADDITIONAL INFORMATION RECEIVED FROM THE MANUFACTURER REPRESENTATIVE THAT THE INSTRUMENTS WERE DULL AND HARD TO ADVANCE. PHYSICIAN FELT THE NAV 2.4 DRILL BITS (BRAND NEW) AND OUR TAPS WERE DULL. THERE WAS A 1 HOUR DELAY IN PROCEDURE DUE TO RE-SPINNING AND TRYING TO SEAT THE ROD WITH THE MISPLACED SCREW AT C2 ADDITIONAL INFORMATION RECEIVED FROM THE MANUFACTURER REPRESENTATIVE THAT THE EVENT IS AN OUT OF BOX FAILURE AS PER PHYSICIAN. THE GENERAL OBSERVATION OF THE P
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11065991 ↗InjuryJul 6, 2020Break; Break
INFORMATION WAS RECEIVED FROM A HEALTH CARE PROVIDER VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT WITH L4-S1 SPINAL STENOSIS DUE TO TUMOR AT L4-S1 FOR SPINAL SURGERY. THE PROCEDURE PERFORMED WAS T2-S2 POSTERIOR SPINE FUSION. IT WAS REPORTED THAT THE SURGEON USED THE NAV INFINITY DRILL TO MAKE THE STARTING HOLES TO SET THE TRAJECTORY FOR THE SCREWS IN THE LUMBAR SPINE AND PELVIS. WHEN DRILLING FOR THE S2 ALAR ILIAC TRAJECTORY THE TIP OF THE DRILL (~30MM) BROKE OFF INSIDE THE PATIENT¿S PELVIS. THE DRILL BIT WAS USED WITHOUT THE DRILL GUIDE WHEN PLACING THE S2 SCREW. SURGEON THEN USED A SOLERA AWL TIP TAP TO CHANGE THE TRAJECTORY OF THE PILOT HOLE AWAY FROM THE FRAGMENT. A SOLERA 5.5 SCREW WAS PLACED SAFELY IN THE NEW TRAJECTORY, AWAY FROM THE BROKEN FRAGMENT. TOWARDS THE COMPLETION OF THE CASE AN O-ARM SPIN CONFIRMED THE LOCATION OF DRILL BIT FRAGMENT IN THE PATIENT¿S PELVIS. THE LEVELS IMPLANTED WAS L2-PELVIS. THERE WAS A FRAGMENT OF THE IMPLANT OR INSTRUMENT REMAINING IN THE PATIENT. THERE WERE NO PATIENT SYMPTOMS OR COMPLICATIONS AS A RESULT OF THIS EVENT. THERE WAS NO TREATMENT OR ADDITIONAL SURGERY PERFORMED AS A RESULT OF TH IS EVENT.
Patient problems: Foreign Body In Patient
MAUDE report 10231508 ↗
Other Orthopedic stereotaxic instrument devices
- REAL INTELLIGENCE ROB10024Smith & Nephew, Inc. · Orthopedic stereotaxic instrument1 recall924 reports
- NA 209063Mako Surgical Corp. · Orthopedic stereotaxic instrument2 recalls602 reports
- RESTORIS, RIO 212760Mako Surgical Corp. · Orthopedic stereotaxic instrument605 reports
- REAL INTELLIGENCE ROB10013Smith & Nephew, Inc. · Orthopedic stereotaxic instrument1 recall528 reports
- VELYS 4515-70-105Depuy (Ireland) · Orthopedic stereotaxic instrument578 reports
- VELYS 4515-70-106Depuy (Ireland) · Orthopedic stereotaxic instrument564 reports
- NA 209999Mako Surgical Corp. · Orthopedic stereotaxic instrument522 reports
- Mazor X System TPL0059-06Mazor Robotics Ltd · Orthopedic Stereotaxic Instrument2 recalls2 deaths392 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page