Angiographic Guide Wire 007447Recalls & reported problems
Medtronic, Inc. · WIRE ANG 007447 10PK 9366S.035 145 3MMJ · Class 2
All models of Angiographic Guide Wire (8)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00643169856844), received between Sep 10, 2018 and Sep 22, 2023 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Material Deformation” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Material Deformation4
- Detachment of Device or Device Component1
Patient problems
- No Consequences Or Impact To Patient3
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 22, 2023Detachment of Device or Device Component; Material Deformation; Detachment of Device or Device Component; Material Deformation
AN ATTEMPT WAS MADE TO USE ONE ANGIOGRAPHIC GUIDEWIRE DURING A CARDIAC PROCEDURE. THE DEVICE WAS NOT INSPECTED BEFORE USE. RESISTANCE WAS NOT NOTED DURING DELIVERY OF THE DEVICE. IT WAS REPORTED THAT THE OUTER SPIRALED LAYER OF THE WIRE UNRAVELED AT THE DISTAL END WHERE THERE IS A GAP BETWEEN THE SPIRAL LAYERS. THE ISSUE OCCURRED WHILE REMOVING THE WIRE FROM THE NON-MEDTRONIC GUIDE CATHETER OUTSIDE THE PATIENT, AFTER THE DEVICE HAD BEEN INSIDE THE PATIENT. THE DEFORMATION AND DETACHMENT WERE NOTED AFTER THE DEVICE WAS REMOVED. RESISTANCE WAS NOT NOTED DURING WITHDRAWAL OF THE DEVICE. THE DETACHED PORTION OF THE DEVICE WAS SUCCESSFULLY REMOVED FROM THE GUIDE CATHETER AND DISCARDED. IT WAS ALSO DETAILED THAT THE SAME ISSUE OCCURRED WITH A NON-MEDTRONIC GUIDEWIRE AT THE BEGINNING OF THE PROCEDURE. THERE WAS NO INJURY TO THE PATIENT AS A RESULT OF THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17797012 ↗MalfunctionJan 23, 2020Material Deformation; Material Deformation
IT WAS REPORTED IN PE 703553375 0.035 X 145CM PTFE GUIDE WIRES BECAME DEFORMED DURING SEVERAL PROCEDURES. IT WAS REPORTED THAT THE OUTER CORE OF THE WIRE SEPARATED FROM THE INNER CORE OF THE WIRE. THERE WAS NO IMPACT TO THE PATIENT AND THEIR CURRENT STATUS IS GOOD.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9620084 ↗MalfunctionJan 23, 2020Material Deformation; Material Deformation
A 0.035 X 145CM PTFE GUIDE WIRE WAS USED DURING A PROCEDURE TO TREAT A NON TORTUOUS, NON CALCIFIED LESION. IT WAS REPORTED THAT THE OUTER CORE OF THE WIRE SEPARATED FROM THE INNER CORE OF THE WIRE. THE PATIENT IS ALIVE WITH NO INJURY. THEIR WAS NO IMPACT TO THE PATIENT AND THEIR CURRENT STATUS IS GOOD. SR (B)(4) WAS CREATED FOR THE COMMENT "IT HAS OCCURRED ON/DURING SEVERAL PROCEDURES."
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9620048 ↗MalfunctionSep 10, 2018Material Deformation; Material Deformation
THE ANGIO GRAPHIC J WIRE WAS INITIALLY OBSERVED AND UTILIZED IN THE LEFT PROXIMAL POPLITEAL ARTERY WITHOUT ISSUE. THE WIRE WAS PREPPED FOR USE AS PER THE IFU. THE TARGET LESION HAD PLAQUE PRESENT, LITTLE CALCIFICATION, LITTLE TORTUOSITY AND 40-50% STENOSIS. NO RESISTANCE WAS FELT ADVANCING THE WIRE. UPON THE 4TH USE AND REMOVAL OF THE J WIRE FROM THE CATHETER, IT WAS NOTICED THE WIRE SEEMED LONGER THAN EARLIER USAGE AND UPON FURTHER OBSERVATION, A SMALLER TRANSITION IN DIAMETER OF THE WIRE WAS ALSO NOTICED AT THE DISTAL END. FLUOROSCOPY WAS UTILIZED BY THE PHYSICIAN TO CONFIRM THAT THE ENTIRE WIRE WAS REMOVED. NO PATIENT INJURY IS REPORTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7859542 ↗
Other WIRE, GUIDE, CATHETER devices
- HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL II 1009664Abbott Vascular Inc. · WIRE, GUIDE, CATHETER321 reports
- SYNCHRO 14 M00313010Stryker Corporation · WIRE, GUIDE, CATHETER2 recalls220 reports
- PressureWire™ C12059Lightlab Imaging, Inc. · WIRE, GUIDE, CATHETER1 death296 reports
- SYNCHRO 2 M00326410Stryker Corporation · WIRE, GUIDE, CATHETER2 recalls155 reports
- ENROUTE .014" Guidewire 11686-01Silk Road Medical, Inc. · Wire, Guide, Catheter2 deaths228 reports
- ARROW IPN035915Teleflex Incorporated · WIRE, GUIDE, CATHETER217 reports
- OmniWire Pressure guide wire 89185Philips Image Guided Therapy Corporation · Wire, Guide, Catheter1 recall1 death160 reports
- ARROW IPN055780Teleflex Incorporated · Wire, guide, catheter4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.