HIgH-Flo™ Needle Set RMS52609Recalls & reported problems
Repro Med Systems, Inc. · 26 Gauge Needle Sets - 5 needles - 9 mm · Class 2
All models of HIgH-Flo Needle Set (11)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00659443000452), received between Oct 24, 2024 and Oct 24, 2024 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Fail-Safe Did Not Operate” (2 reports).
2 other recalls cover devices cleared under the same FDA submission (K122404, K200176, K211206, K214045, K252015); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Fail-Safe Did Not Operate2
Patient problems
- Needle Stick/Puncture1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 24, 2024Fail-Safe Did Not Operate; Fail-Safe Did Not Operate
KORU MEDICAL BECAME AWARE OF 2 NEEDLE STICK REPORTS INVOLVING KORU HIGH FLO SUBCUTANEOUS SAFETY NEEDLE SETS. IN BOTH CASES, THE NEEDLE SETS HAD BEEN USED ON PATIENTS. MDR 1318360-2024-00008 IS BEING FILED FOR NURSE #1, NEEDLE STICK/PUNCTURE REPORT. ADDITIONAL INFORMATION WAS RECEIVED FOR NURSE#2 ON (B)(6) 2024 STATING THE NURSE REMOVED THE INFUSION NEEDLES FROM THE PATIENT AND EACH NEEDLE WAS SNAPPED SHUT UPON REMOVAL (HEARD THE SNAP). WHILE DISPOSING OF THE INFUSION SET, ONE OF THE NEEDLES OPENED UP AND THE NURSE WAS PUNCTURED ON THE RIGHT INDEX FINGER. THE DATE OF OCCURRENCE FOR THIS EVENT IS (B)(6) 2024. MDR 1318360-2024-00009 IS BEING FILED FOR THE FIRST OCCURRENCE INVOLVING NURSE #2. WHILE TEACHING THE PATIENT THE FOLLOWING DAY ((B)(6) 2024), ALL NEEDLE WINGS AUDIBLY SNAPPED SHUT AND ONE REOPENED AFTER REMOVAL AND SNAPPING. A NEEDLE STICK DID NOT OCCUR IN THIS CASE. THIS MDR IS BEING FILED FOR THE SECOND OCCURRENCE WITH NURSE #2. THE NURSE WAS WEARING PPE (GLOVES) AT THE TIME THE EVENTS OCCURRED. THE NURSE FOLLOWED THE COMPANY'S PROTOCOL FOR REPORTING, EVALUATION, ETC. NO ADVERSE EVENT OUTCOMES WERE REPORTED TO HAVE OCCURRED. THE INITIAL REPORTER DID NOT PROVIDE ANY IDENTIFYIN
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20528469 ↗MalfunctionOct 24, 2024Fail-Safe Did Not Operate; Fail-Safe Did Not Operate
KORU MEDICAL BECAME AWARE OF 2 NEEDLE STICK REPORTS INVOLVING KORU HIGH FLO SUBCUTANEOUS SAFETY NEEDLE SETS. IN BOTH CASES, THE NEEDLE SETS HAD BEEN USED ON PATIENTS. MDR 1318360-2024-00008 IS BEING FILED FOR NURSE #(B)(4), NEEDLE STICK/PUNCTURE REPORT. ADDITIONAL INFORMATION WAS RECEIVED FOR NURSE#(B)(4) ON (B)(6)2024 STATING THE NURSE REMOVED THE INFUSION NEEDLES FROM THE PATIENT AND EACH NEEDLE WAS SNAPPED SHUT UPON REMOVAL (HEARD THE SNAP). WHILE DISPOSING OF THE INFUSION SET, ONE OF THE NEEDLES OPENED UP AND THE NURSE WAS PUNCTURED ON THE RIGHT INDEX FINGER. THE DATE OF OCCURRENCE FOR THIS EVENT IS (B)(6)2024. WHILE TEACHING THE PATIENT THE FOLLOWING DAY ((B)(6)2024), ALL NEEDLE WINGS AUDIBLY SNAPPED SHUT AND ONE REOPENED AFTER REMOVAL AND SNAPPING. A NEEDLE STICK DID NOT OCCUR IN THIS CASE. MDR 1318360-2024-00010 IS BEING FILED FOR THE SECOND OCCURRENCE WITH NURSE #(B)(4). THE NURSE WAS WEARING PPE (GLOVES) AT THE TIME THE EVENTS OCCURRED. THE NURSE FOLLOWED THE COMPANY'S PROTOCOL FOR REPORTING, EVALUATION, ETC. NO ADVERSE EVENT OUTCOMES WERE REPORTED TO HAVE OCCURRED. THE INITIAL REPORTER DID NOT PROVIDE ANY IDENTIFYING INFORMATION FOR THE NURSE DUE TO CONFIDENTIALITY. THE L
Patient problems: Needle Stick/Puncture
MAUDE report 20527801 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K122404, K200176, K211206, K214045, K252015. One submission often covers many models, so check the product and lot details in each record.
- Z-0051-2020 · Aug 20, 2019 · Terminated20" 2-Needle 26-Gauge 6mm HlgH-Flo Subcutaneous Safety Needle Sets" Product # RMS22606 - Product Usage: RMS HlgH-Flo Subcutaneous Safety Needle Sets are intended for the delivery
- Z-0318-2018 · Mar 10, 2016 · TerminatedHIgH-Flo Subcutaneous Safety Needle Sets, 2-Needle Set/ 24 Gauge 9mm Needles, REF/Part Numbers RMS22606, RMS22609, RMS22612, RMS12606, RMS22409, RMS32609, RMS32609, RMS12409, RMS1
Other Set, administration, intravascular devices
- Autosoft XC 1001680Unomedical A/S · Set, Administration, Intravascular1 death16,105 reports
- Autosoft90™ 1002817Unomedical A/S · Set, Administration, Intravascular1 recall11,907 reports
- Minimed™ Quick-set™ MMT-399AUnomedical A/S · Set, Administration, Intravascular9 deaths8,669 reports
- Medtronic Extended MMT-431AUnomedical A/S · Set, Administration, Intravascular3 deaths8,574 reports
- MiniMed™ Mio™ Advance MMT-242AUnomedical A/S · Set, Administration, Intravascular15 deaths8,164 reports
- CADD 21-7302-24Icu Medical, Inc. · Set, administration, intravascular4 recalls1 death4,657 reports
- Autosoft XC 1001681Unomedical A/S · Set, Administration, Intravascular1 death4,216 reports
- Minimed™ Quick-set™ MMT-397AUnomedical A/S · Set, Administration, Intravascular19 deaths4,134 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page