ook snow FL36 ook snow (REF FL36)Recalls & reported problems
Umano Medical Inc · The ook snow is an AC-powered medical bed that offers an optional bed status monitoring system. The bed maximum safe working load is of 600lb and a service life of 15 years. · Class 2
All models of ook snow (7)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00670482000500), received between Oct 20, 2022 and Jan 15, 2025 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Communication or Transmission Problem” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Communication or Transmission Problem2
- Electrical Shorting2
- Defective Alarm1
- Detachment of Device or Device Component1
- Improper or Incorrect Procedure or Method1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
- Bruise/Contusion1
- Fall1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 15, 2025Defective Alarm; Improper or Incorrect Procedure or Method; Defective Alarm; Improper or Incorrect Procedure or Method
ON (B)(6) 2024, A CUSTOMER REPORTED TO THE MANUFACTURER'S TECHNICAL SERVICE THAT THE BED EXIT MONITORING SYSTEM WAS TRIGGERING AN ALARM IMMEDIATELY UPON ARMING. THE SITE'S TECHNICIAN INITIATED TROUBLESHOOTING, BUT THE ISSUE REMAINED UNRESOLVED. TROUBLESHOOTING WAS SCHEDULED TO CONTINUE THE FOLLOWING DAY, AND THE MEDICAL STAFF CONTINUED TO USE THE DEVICE. ON (B)(6) 2024, DURING TROUBLESHOOTING, THE SITE'S TECHNICIAN INFORMED THE MANUFACTURER THAT A PATIENT HAD FALLEN FROM THE BED THE PREVIOUS NIGHT (EXACT DATE AND TIME NOT DISCLOSED). THE BED ACTIVITY LOG CONFIRMED THAT THE BED EXIT MONITORING SYSTEM WAS ACTIVATED AT 21:03 AND AN ALARM WAS TRIGGERED AT 8:41.
Patient problems: Bruise/Contusion; Fall
MAUDE report 21162327 ↗MalfunctionMar 5, 2024Detachment of Device or Device Component; Detachment of Device or Device Component
CUSTOMER CALLED THE TECHNICAL SERVICE OF MANUFACTURER TO REPORT ABOUT A BED WITH TWO BROKEN BRAKE BARS. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18837556 ↗MalfunctionJun 27, 2023Communication or Transmission Problem; Communication or Transmission Problem
THE MANUFACTURER WAS CONTACTED BY CUSTOMER ALLEGING THAT THE NURSE CALL SIGNAL WAS NOT BEING RECEIVED THROUGH THE NURSE CALL SYSTEM. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17209070 ↗MalfunctionDec 1, 2022Communication or Transmission Problem; Communication or Transmission Problem
TECHNICAL SERVICE OF THE MANUFACTURER WAS INFORMED THAT THE BRAKE BED STATUS OF HOSPITAL BED WORKS INTERMITTENTLY. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15898175 ↗MalfunctionOct 20, 2022Electrical Shorting; Electrical Shorting
CUSTOMER REPORTED TO UMANO REPRESENTATIVE THAT THE BED IS OVERLOADING THE NURSE CALL CIRCUIT BOARD MAKING IT NON FUNCTIONAL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15638143 ↗MalfunctionOct 20, 2022Electrical Shorting; Electrical Shorting
CUSTOMER REPORTED TO UMANO REPRESENTATIVE THAT THE BED IS OVERLOADING THE NURSE CALL CIRCUIT BOARD MAKING IT NON FUNCTIONAL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15638017 ↗
Other Bed, Ac-Powered Adjustable Hospital devices
- Centrella™ Bed P7900BHill-Rom, Inc. · BED, AC-POWERED ADJUSTABLE HOSPITAL2 recalls5 deaths1,937 reports
- Progressa® Bed System P7500AHill-Rom, Inc. · BED, AC-POWERED ADJUSTABLE HOSPITAL1 recall1 death1,377 reports
- VersaCare® Med Surg Bed P3200KHill-Rom, Inc. · BED, AC-POWERED ADJUSTABLE HOSPITAL3 deaths1,193 reports
- Medline MDR107002EMedline Industries, Inc. · BED, AC-POWERED ADJUSTABLE HOSPITAL1 recall1 death374 reports
- Medline MDR107003EMedline Industries, Inc. · BED, AC-POWERED ADJUSTABLE HOSPITAL1 recall3 deaths362 reports
- InTouch 2141Stryker Corporation · BED, AC-POWERED ADJUSTABLE HOSPITAL2 deaths361 reports
- Citadel Plus FX811B3B4AMABBArjohuntleigh AB · BED, AC-POWERED ADJUSTABLE HOSPITAL2 deaths358 reports
- TotalCare® Bed P1900QHill-Rom, Inc. · BED, AC-POWERED ADJUSTABLE HOSPITAL317 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page