HANCOCK® HC105-20Recalls & reported problems
Medtronic, Inc. · CONDUIT HC105-20 HKI LOW POROSITY 10L · Class 3 · Implant
All models of HANCOCK (22)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 9
- Deaths reported
- 0
- Injuries reported
- 9
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 00681490908597), received between May 1, 2018 and Jan 6, 2023 — classified as 9 injuries.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (7 reports).
1 other recall cover devices cleared under the same FDA submission (P870078); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Insufficient Device Problem Information7
- Calcified1
- Gradient Increase1
Patient problems
- Insufficient Information4
- Pulmonary Valve Stenosis3
- Corneal Pannus2
- No Information2
- Aortic Valve Stenosis1
- Calcium Deposits/Calcification1
- Pulmonary Regurgitation1
- Pulmonary Valve Insufficiency/ Regurgitation1
Recent adverse event reports
The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.
InjuryJan 6, 2023Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT 8 YEARS AND 8 MONTHS POST IMPLANT OF THIS 20MM PULMONARY VALVED CONDUIT IN A 10 YEAR OLD PEDIATRIC PATIENT, IT WAS EXPLANTED AND REPLACED WITH A 22MM CONDUIT OF THE SAME MODEL. THE REASON FOR REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Insufficient Information
MAUDE report 16113155 ↗InjuryMay 26, 2022Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT AFTER AN UNSPECIFIED DURATION POST IMPLANT OF THIS 20MM AORTIC VALVED CONDUIT IN A 12 YEAR OLD PEDIATRIC PATIENT, IT WAS EXPLANTED AND REPLACED WITH A 21MM NON-MEDTRONIC BIOPROSTHETIC VALVE. THE REASON FOR REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Insufficient Information
MAUDE report 14519358 ↗InjuryJan 25, 2022Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT 9 YEARS AND 11 MONTHS POST IMPLANT OF THIS 20 MM PULMONARY BIOPROSTHETIC VALVE, IT WAS EXPLANTED AND REPLACED WITH A 25 MM VALVE OF THE SAME MODEL. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Insufficient Information
MAUDE report 13342814 ↗InjuryOct 15, 2021Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT 11 YEARS AND 2 MONTHS POST IMPLANT OF THIS 20MM PULMONARY VALVED CONDUIT, A TRANSCATHETER PULMONARY BIOPROSTHETIC VALVE (TPBV) WAS IMPLANTED VALVE-IN-VALVE. THE REASON FOR REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Insufficient Information
MAUDE report 12642386 ↗InjuryNov 30, 2020Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT 8 YEARS AND 1 MONTH POST IMPLANT OF THIS 20MM PULMONARY VALVED CONDUIT IN A (B)(6)-YEAR-OLD PEDIATRIC PATIENT, A TRANSCATHETER PULMONARY BIOPROSTHETIC VALVE (TPBV) WAS IMPLANTED VALVE-IN-VALVE. THE REASON FOR REPLACEMENT WAS REPORTED AS MODERATE-SEVERE PULMONARY REGURGITATION WITH MILD STENOSIS. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Pulmonary Valve Insufficiency/ Regurgitation; Pulmonary Valve Stenosis
MAUDE report 10920072 ↗InjuryJan 28, 2019Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT 16 YEARS AND 8 MONTHS POST IMPLANT OF THIS PULMONARY VALVED CONDUIT, A TRANSCATHETER PULMONARY BIOPROSTHETIC VALVE (TPBV) WAS IMPLANTED VALVE-IN-VALVE. THE REASON FOR INTERVENTION WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Aortic Valve Stenosis; No Information
MAUDE report 8282769 ↗InjuryNov 19, 2018Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT 10 YEARS AND 2 MONTHS POST IMPLANT OF THIS PULMONARY VALVED CONDUIT IN AN 8 YEAR OLD PEDIATRIC PATIENT, A TRANSCATHETER PULMONARY BIOPROSTHETIC VALVE (TPBV) WAS IMPLANTED VALVE-IN-VALVE. THE REASON FOR INTERVENTION WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: No Information
MAUDE report 8085183 ↗InjuryMay 11, 2018Calcified; Calcified
MEDTRONIC RECEIVED INFORMATION THAT EIGHT YEARS POST IMPLANT OF THIS BIOPROSTHETIC VALVED CONDUIT, IMPLANTED IN A (B)(6) YEAR OLD PEDIATRIC PATIENT, A TRANSCATHETER PULMONARY BIOPROSTHETIC VALVE (TPBV) WAS IMPLANTED VALVE-IN-VALVE. THE REASON FOR REPLACEMENT WAS REPORTED AS MODERATE TO SEVERE STENOSIS. SIX YEARS AND NINE MONTHS POST VALVE-IN-VALVE, BOTH PRODUCTS WERE EXPLANTED AND REPLACED WITH ANOTHER BIOPROSTHETIC VALVED CONDUIT. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Calcium Deposits/Calcification; Corneal Pannus; Pulmonary Valve Stenosis
MAUDE report 7508889 ↗InjuryMay 1, 2018Gradient Increase; Gradient Increase
MEDTRONIC RECEIVED INFORMATION THAT FOUR YEARS AND TWO MONTHS POST IMPLANT OF THIS BIOPROSTHETIC VALVE IN A SEVEN YEAR OLD PEDIATRIC PATIENT, A TRANSCATHETER PULMONARY BIOPROSTHETIC VALVE WAS IMPLANTED VALVE-IN-VALVE DUE TO A GRADIENT MEASUREMENT OF 90MMHG, REGURGITATION AND STENOSIS. PRIOR TO REPLACEMENT, AN ECHOCARDIOGRAM (ECG) WAS PERFORMED THAT REVEALED THE GRADIENT MEASUREMENT WHILE THE PATIENT WAS EXERCISING. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Corneal Pannus; Pulmonary Regurgitation; Pulmonary Valve Stenosis
MAUDE report 7476439 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P870078. One submission often covers many models, so check the product and lot details in each record.
- Z-2623-2014 · Aug 15, 2014 · TerminatedHancock Apical Left Ventricle Connector, Model No. H174Axx, Catalog No. 0174ACP012. Used use in conjunction with Hancock Conduit Model 105 to provide an alternate method for reli
Other replacement Heart-valve devices
- CARPENTIER-EDWARDS PERIMOUNT MAGNA EASE PERICARDIAL BIOPROSTHESIS - AORTIC 3300TFXEdwards Lifesciences LLC · replacement Heart-valve4 deaths671 reports
- CARPENTIER-EDWARDS PERIMOUNT MAGNA EASE PERICARDIAL BIOPROSTHESIS - AORTIC 3300TFXEdwards Lifesciences LLC · replacement Heart-valve1 death656 reports
- CARPENTIER-EDWARDS PERIMOUNT MAGNA EASE PERICARDIAL BIOPROSTHESIS - AORTIC 3300TFXEdwards Lifesciences LLC · replacement Heart-valve5 deaths533 reports
- CARPENTIER-EDWARDS PERIMOUNT MAGNA MITRAL EASE PERICARDIAL BIOPROSTHESIS 7300TFXEdwards Lifesciences LLC · replacement Heart-valve1 death425 reports
- CARPENTIER-EDWARDS PERIMOUNT MAGNA MITRAL EASE PERICARDIAL BIOPROSTHESIS 7300TFXEdwards Lifesciences LLC · replacement Heart-valve1 death391 reports
- CARPENTIER-EDWARDS PERIMOUNT MAGNA MITRAL EASE PERICARDIAL BIOPROSTHESIS 7300TFXEdwards Lifesciences LLC · replacement Heart-valve1 death290 reports
- CARPENTIER-EDWARDS PERIMOUNT MAGNA EASE PERICARDIAL BIOPROSTHESIS - AORTIC 3300TFXEdwards Lifesciences LLC · replacement Heart-valve260 reports
- CARPENTIER-EDWARDS PERIMOUNT MAGNA MITRAL EASE PERICARDIAL BIOPROSTHESIS 7300TFXEdwards Lifesciences LLC · replacement Heart-valve2 deaths229 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page