VersaCross Access Solution VXSK0024 (REF NA)Recalls & reported problems
Baylis Médicale Cie Inc · 1 x VersaCross Transseptal Sheath (including 1 x J-tip Guidewire); 1 x VersaCross RF Wire (including 1 x Connector Cable (Single Use)) · Class 2
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00685447011750), received between Mar 20, 2024 and Jun 24, 2024 — classified as 1 injury, 2 malfunctions.
The most frequently reported specific device problem is “Difficult to Advance” (1 report).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Recalls naming this device
- Jun 10, 2025Open, Classified
Potential for hole in the Tyvek layer of the sterile barrier pouch, which may compromise device sterility. Issue could potentially lead to systemic infection and sepsis in worst case scenario. Potential punctures may go undetected in clinical settings due to small size and variable location.
Z-2103-2025 · Root cause: Packaging change control · FDA record ↗
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Difficult to Advance1
- Material Frayed1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- Cardiac Perforation1
- Low Blood Pressure/ Hypotension1
- Pericardial Effusion1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 24, 2024Material Frayed; Material Frayed
IT HAS BEEN REPORTED THAT A VERSACROSS ACCESS SOLUTION KIT WAS SELECTED FOR USE FOR AN ATRIAL FIBRILLATION (A FIB) ABLATION PROCEDURE. DURING THE PROCEDURE, AS THE PHYSICIAN WAS ATTEMPTING TO GET ACCESS WITH VERSACROSS RF WIRE, HE WAS EXPERIENCING DIFFICULTY INSERTING THE VERSACROSS SHEATH INTO THE PATIENT'S RIGHT FEMORAL VEIN. THEREFORE, THE PHYSICIAN REMOVED THE VERSACROSS RF WIRE AND NOTICED THAT PART OF THE DEVICE WAS FRAYING AT ITS DISTAL END. THE RF WIRE WAS INSERTED THROUGH A NON-BOSTON SCIENTIFIC INTRODUCER NEEDLE PRIOR TO THE ISSUE BEING NOTED. THE RF WIRE WAS THEN REPLACED, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO PATIENT COMPLICATIONS WERE REPORTED. PRODUCT IS NOT EXPECTED TO RETURN FOR ANALYSIS (DISPOSED).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19600686 ↗MalfunctionApr 15, 2024Difficult to Advance; Difficult to Advance
IT WAS REPORTED THAT DURING A PROCEDURE, A VERSACROSS ACCESS SOLUTION KIT WAS SELECTED FOR USE. IT WAS NOTED THAT THE DEVICE WAS NOT ABLE TO GO TRANSSEPTAL. NO FURTHER DETAILS WERE PROVIDED. THE PROCEDURE OUTCOME IS UNKNOWN. NO PATIENT COMPLICATIONS WERE REPORTED. THE DEVICE IS EXPECTED TO BE RETURNED FOR ANALYSIS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19105400 ↗InjuryMar 20, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED A PERICARDIAL EFFUSION OCCURRED. DURING AN ATRIAL FIBRILLATION (A FIB) PROCEDURE, A VERSACROSS ACCESS SOLUTION KIT WAS SELECTED FOR USE. A PERICARDIAL EFFUSION (PE) WAS NOTED WHEN THE TRANSSEPTAL PUNCTURE (TSP) WAS BEING PERFORMED USING VERSACROSS SHEATH AND RADIO FREQUENCY WIRE. THE PE WAS CONFIRMED USING AN ULTRASOUND SCAN WITH A NON-BOSTON SCIENTIFIC CATHETER. HENCE, THE ABLATION WAS NOT COMPLETED. THE PATIENT BLOOD PRESSURE WAS DROPPED. A PERICARDIOCENTESIS WAS PERFORMED AND THE PATIENT WAS STABILIZED. THE DEVICE IS NOT EXPECTED TO BE RETURNED FOR ANALYSIS. EVENT REPORTED VIA MEDWATCH MDR REPORT # MW5151066.
Patient problems: Cardiac Perforation; Low Blood Pressure/ Hypotension; Pericardial Effusion
MAUDE report 18941532 ↗
Other Catheter, Septostomy devices
- VersaCross Access Solution VXSK0031Baylis Médicale Cie Inc · Catheter, Septostomy1 recall16 reports
- VersaCross Access Solution VXSK0021Baylis Médicale Cie Inc · Catheter, Septostomy1 recall1 death15 reports
- VersaCross Access Solution VXSK0032Baylis Médicale Cie Inc · Catheter, Septostomy1 recall14 reports
- VersaCross Access Solution VXSK0022Baylis Médicale Cie Inc · Catheter, Septostomy1 recall13 reports
- VersaCross Access Solution VXSK0034Baylis Médicale Cie Inc · Catheter, Septostomy1 recall1 report
- VersaCross Access Solution VXSK0025Baylis Médicale Cie Inc · Catheter, Septostomy1 recall1 report
- NRG Transseptal Needle NRG-E-HF-71-C0Boston Scientific Corporation · Catheter, Septostomy22 reports
- NRG Transseptal Needle NRG-E-HF-71-C1Boston Scientific Corporation · Catheter, Septostomy2 deaths17 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.