VersaCross Access Solution VXSK0025Recalls & reported problems

Baylis Médicale Cie Inc · 1 x VersaCross Transseptal Sheath (including 1 x J-tip Guidewire); 1 x VersaCross RF Wire (including 1 x Connector Cable (Single Use)) · Class 2

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
1

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00685447011767), received between Jun 12, 2024 and Jun 12, 2024 — classified as 1 injury.

The most frequently reported specific device problem is “Positioning Problem” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Jun 10, 2025Open, Classified

    Potential for hole in the Tyvek layer of the sterile barrier pouch, which may compromise device sterility. Issue could potentially lead to systemic infection and sepsis in worst case scenario. Potential punctures may go undetected in clinical settings due to small size and variable location.

    Z-2103-2025 · Root cause: Packaging change control · FDA record ↗

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Positioning Problem1

Patient problems

  • Air Embolism1
  • Ischemia1
  • Low Blood Pressure/ Hypotension1
  • Non specific EKG/ECG Changes1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 12, 2024Adverse Event Without Identified Device or Use Problem; Positioning Problem; Adverse Event Without Identified Device or Use Problem; Positioning Problem

    AN AIR EMBOLISM OCCURRED, AND THE PROCEDURE WAS CANCELLED. DURING THE PROCEDURE, A VERSACROSS ACCESS SOLUTION KIT WAS SELECTED FOR USE FOR AN ATRIAL FIBRILLATION (A FIB) ABLATION PROCEDURE. IT WAS REPORTED THAT THE MONITOR DISPLAYED "AIR INGRESS", THUS THE PROCEDURE WAS CANCELLED. THE PHYSICIAN ASPIRATED THE EMBOLISM AND CONFIRMED THAT THERE WAS AIR INSIDE OF THE PATIENT ON IMAGING. NO OTHER ISSUES WERE REPORTED. A NON-BOSTON SCIENTIFIC SMALL BORE LASSO CATHETER WAS USED AFTER TRANSSEPTAL. THE IRRIGATION WAS NEVER INTERRUPTED OR STOPPED DURING THE PROCEDURE. IN THE PHYSICIAN'S OPINION, THE VERSACROSS DEVICES DID NOT MALFUNCTION DURING THE PROCEDURE NOR CONTRIBUTE TO THE ADVERSE EVENT. IT IS EXPECTED FOR THE PATIENT TO FULLY RECOVER. PRODUCT IS NOT EXPECTED TO RETURN FOR ANALYSIS (DISPOSED). IT WAS FURTHER REPORTED THAT A VERSACROSS CONNECT ACCESS SOLUTION WAS ALSO SELECTED FOR USE FOR THE WATCHMAN PROCEDURE, GUIDED BY A TRANSESOPHAGEAL ECHOCARDIOGRAM (TEE). THE VERSACROSS RF WIRE WAS USED AS A STARTER WIRE. A TOTAL OF FOUR (4) TRANSSEPTAL PUNCTURES ATTEMPTS (TSP) WITH VERSACROSS CONNECT WERE DONE, ALL TOO POSTERIOR AND HIGH, LEADING TO MULTIPLE FAILED WATCHMAN DEPLOYMENTS. THEREFOR

    Patient problems: Air Embolism; Ischemia; Low Blood Pressure/ Hypotension; Non specific EKG/ECG Changes

    MAUDE report 19523240 ↗

Other Catheter, Septostomy devices

All Catheter, Septostomy devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.