VersaCross Connect LAAC Access Solution VXAK0009 (REF NA)Recalls & reported problems

Baylis Médicale Cie Inc · 1 x VersaCross Connect Transseptal Dilator (including 1 x J-tip Mechanical Guidewire); 1 x VersaCross RF Wire (including 1 x Connector Cable (Single Use)) · Class 2

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00685447012603), received between May 24, 2024 and May 24, 2024 — classified as 1 injury.

The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device-Device Incompatibility1

Patient problems

  • Cardiac Perforation1
  • Cardiac Tamponade1
  • Pericardial Effusion1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 24, 2024Device-Device Incompatibility; Device-Device Incompatibility

    IT HAS BEEN REPORTED THAT A VERSACROSS CONNECT ACCESS SOLUTION KIT WAS SELECTED FOR USE FOR A LEFT ATRIAL APPENDAGE CLOSURE PROCEDURE INDICATED FOR A CASE OF NONVALVULAR ATRIAL FIBRILLATION (NVAF). A PERFORATION, PERICARDIAL EFFUSION AND CARDIAC TAMPONADE OCCURRED; PROCEDURE CANCELLED. DURING THE PROCEDURE, THE PHYSICIAN MENTIONED THAT THE PATIENT HAD A LIPOMATOUS SEPTUM WITH LIMITED TRANSSEPTAL CROSSING OPTIONS. THE VERSACROSS DEVICES WERE USED FOR TRANSSEPTAL. THE LOCATION OF THE CROSSING WAS MID-MID AND THE WIRE/SHEATH CROSSED OVER INTO THE LEFT ATRIUM WITH NO COMPLICATIONS. SHORTLY AFTER, IT WAS NOTICED THAT THERE WAS AN INCREASING BUILDUP OF FLUID IN THE TRANSVERSE SINUS. THUS, IT WAS DECIDED TO VIEW THE PERICARDIUM WITH A ABBOTT VIEWFLEX ICE CATHETER, WHICH IS WHEN THEY SAW A LARGE EFFUSION AND TAMPONADE. PERICARDIOCENTESIS AND AN AUTOTRANSFUSION WERE PERFORMED, THE PATIENT BECAME HEMODYNAMICALLY UNSTABLE, REQUIRING INTUBATION. THE PERICARDIOCENTESIS WAS SAID TO BE SUCCESSFUL, ALTHOUGH THE BLEEDING CONTINUED, AND THE EFFUSION DID NOT APPEAR TO BE DECREASING ON ICE. A CARDIOTHORACIC (CT) SURGERY WAS THEN REQUESTED WHERE A STERNOTOMY WAS PERFORMED, AND THE SOURCE OF THE BLEEDIN

    Patient problems: Cardiac Perforation; Cardiac Tamponade; Pericardial Effusion

    MAUDE report 19393137 ↗

Other Dilator, Vessel, For Percutaneous Catheterization devices

All Dilator, Vessel, For Percutaneous Catheterization devices →