Edwards Lifesciences Retrograde Cardioplegia Catheter RC2014MRecalls & reported problems

Edwards Lifesciences LLC · Retrograde Cardioplegia Catheter · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00690103034455), received between Jul 8, 2025 and Jul 8, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Fracture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture1

Patient problems

  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 8, 2025Fracture; Fracture

    IT WAS REPORTED THAT THE PART A FEW MILLIMETERS FROM THE TIP OF A RC2014M RETROGRADE CANNULA GOT FRACTURED DURING SURGERY. AT THE DEVICE REMOVAL, THE FRACTURED TIP CAME OFF. AT FIRST AT THE PROCEDURE, ANTEGRADE CARDIOPLEGIA OF A NON-EDWARDS DEVICE WAS USED ONCE FOR MYOCARDIAL PROTECTION, HOWEVER, DUE TO AORTIC REGURGITATION, THE APPROPRIATE AMOUNT COULD NOT BE DELIVERED, SO THEN THE RETROGRADE CARDIOPLEGIA RC2014M WAS USED. MYOCARDIAL PROTECTION WAS DELIVERED THREE TIMES SUCCESSFULLY. THE CANNULA WAS FUNCTIONAL UP UNTIL THEN. WHEN ATTEMPTING THE FOURTH DELIVERY, THE PRESSURE WENT HIGH -AROUND 300 MMHG- THEREFORE THE CANNULA WAS REMOVED. THE PART A FEW MILLIMETERS FROM THE TIP WAS FRACTURED AND ABOUT TO COME OFF, AND WHEN THE DEVICE WAS REMOVED, THE TIP CAME OFF. DURING THE SIMULTANEOUS MAZE PROCEDURE, CRYOICE WAS USED ON THE LEFT ATRIUM, WHICH LED TO A HIGH-PRESSURE SITUATION. FLOW RATE DURING BALLOON INFLATION WAS 200ML PER M. CORONARY SINUS PRESSURE WAS 30 TO 35 MMHG. PEAK PRESSURE WAS 300MMHG. THE PLACEMENT POSITION OF THE CANNULA TIP WAS APPROPRIATE. VISUAL INSPECTION AND INFLATION TEST BEFORE USE WAS NOT PERFORMED. CRYOICE WAS DONE PRIOR TO MVR. AFTER THE DEVICE WAS REMOVED AN

    Patient problems: Insufficient Information

    MAUDE report 22437658 ↗