HemoSphere HEMSGM10Recalls & reported problems

Edwards Lifesciences LLC · HemoSphere Swan-Ganz Module · Class 2

Adverse event reports
5
Deaths reported
0
Injuries reported
3
Recalls naming it
1

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00690103196993), received between Jan 5, 2023 and May 18, 2026 — classified as 3 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (2 reports).

1 FDA recall record name this device's identifier.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 1 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Oct 2, 2017Terminated

    Pre-procedural issues related to software defects

    Z-0496-2018 · Root cause: Device Design · FDA record ↗

Most reported problems

Device problems

  • Incorrect, Inadequate or Imprecise Result or Readings2
  • Adverse Event Without Identified Device or Use Problem1
  • Malposition of Device1
  • Patient Device Interaction Problem1
  • Perivalvular Leak1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Heart Block1
  • Insufficient Information1
  • Stroke/CVA1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 18, 2026Patient Device Interaction Problem

    AS REPORTED FROM GERMANY BY OUR EDWARDS LIFESCIENCES AFFILIATES, HEART BLOCK OCCURRED POST IMPLANT OF A 23MM SAPIEN 3 ULTRA VALVE IN THE AORTIC POSITION BY RIGHT TRANSFEMORAL APPROACH. DURING IMPLANTATION, THE VALVE JUMPED IN LEFT VENTRICLE DIRECTION AND WAS IMPLANTED IN THE 50/50 (AORTIC: VENTRICULAR) POSITION. THE PATIENT HAD GOOD HEMODYNAMICS AND NO PARAVALVULAR LEAK. NO ACTION WAS NEEDED. THE POSITIONING PROBLEMS MAY HAVE OCCURRED DUE TO THE MASSIVE HYPERTROPHY OF LEFT VENTRICLE. AFTER THE IMPLANTATION, A THIRD-DEGREE HEART BLOCK OCCURRED, REQUIRING PACING WITH THE TEMPORARY PACEMAKER USED FOR IMPLANTATION. ADDITIONALLY, A PERMANENT PACEMAKER WAS REQUIRED ON THE SAME DAY AS THE PROCEDURE. THE PATIENT WAS IN A STABLE CONDITION.

    Patient problems: Heart Block

    MAUDE report 25204215 ↗
  • InjuryApr 20, 2026Adverse Event Without Identified Device or Use Problem

    AS REPORTED THROUGH THE JAPANESE TAVI REGISTRY REPORTING SYSTEM, THE PATIENT UNDERWENT A TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVR) AND RECEIVED A 26MM SAPIEN 3 ULTRA RESILIA VALVE. ON POSTOPERATIVE DAY 6, CEREBRAL INFARCTION (CI) WAS OBSERVED.

    Patient problems: Stroke/CVA

    MAUDE report 24926453 ↗
  • InjuryMar 31, 2026Perivalvular Leak; Malposition of Device

    AS REPORTED BY OUR GERMAN AFFILIATE DURING A TRANSFEMORAL TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVR) WITH A 20MM SAPIEN 3 ULTRA VALVE, ALTHOUGH THE VALVE WAS APPROPRIATELY POSITIONED BETWEEN THE BALLOON MARKERS PRIOR TO DEPLOYMENT, DURING VALVE DEPLOYMENT THE 20MM COMMANDER DELIVERY SYSTEM (DS) BALLOON INFLATED UNEXPECTEDLY, WITH THE PROXIMAL (OUTFLOW) PORTION INFLATING FIRST WHILE THE DISTAL (INFLOW) PORTION REMAINED SNARED WITH THE VALVE AND THEN ABRUPTLY INFLATING WITH THE PROXIMAL BALLOON PART, CAUSING AN UNPREDICTABLE VALVE DEPLOYMENT. CONSEQUENTLY, THE VALVE WAS IMPLANTED TOO HIGH IN THE AORTIC POSITION, WITH A HIGHER GRADE OF PARAVALVULAR LEAK OBSERVED ON FINAL FLUOROSCOPY. THE DELIVERY SYSTEM WAS SUBSEQUENTLY REMOVED WITHOUT ANY ISSUES, AND NO DAMAGE WAS OBSERVED ON THE 14FR ESHEATH+ UPON WITHDRAWAL. A SECOND VALVE WAS THEN IMPLANTED MORE VENTRICULAR WHICH RESULTED IN NO PARAVALVULAR LEAK. THE PROCEDURE WAS THEREFORE COMPLETED SUCCESSFULLY. NO INJURY WAS REPORTED, AND THE PATIENT WAS DISCHARGED.

    Patient problems: Insufficient Information

    MAUDE report 24744942 ↗
  • MalfunctionApr 30, 2025Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    AS REPORTED DURING USE THE HEMOSPHERE SWAN GANZ MODULE WAS GIVING INCORRECT VALUES. A NEW MODULE WORKED AS EXPECTED. NO DAMAGE WAS NOTED. THERE WAS NO ADDITIONAL INFORMATION. THERE WAS NO PATIENT INJURY. THE DEVICE IS AVAILABLE FOR EVALUATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21935630 ↗
  • MalfunctionJan 5, 2023Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED THAT THERE WAS A MALFUNCTION WITH THE SWAN GANZ MODULE DURING PATIENT MONITORING. THERE WERE INCONSISTENT CO/CI READINGS. THEY EXCHANGED FOR DIFFERENT SWAN CATHETERS AND IT DID NOT RESOLVE THE ISSUE. THEY EXCHANGED THE SG MODULE FOR TROUBLESHOOTING. THERE WERE NO ERROR MESSAGES DISPLAYED. THERE IS NO PHYSICAL DAMAGE APPARENT. THE EDWARDS FIELD REPRESENTATIVE HAS ATTEMPTED TO OBTAIN ADDITIONAL INFORMATION, BUT HAS NOT BEEN SUCCESSFUL. THERE WAS NO INAPPROPRIATE PATIENT TREATMENT ADMINISTERED. THERE WAS NO PATIENT HARM OR INJURY. THE PATIENT DEMOGRAPHIC INFORMATION IS NOT AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16108715 ↗

Other Catheter, Oximeter, Fiberoptic devices