Skip to content

Heli-FX™ EndoAnchor™ System SG-64 (UDI 00763000006624)Recalls & reported problems

Medtronic, Inc. · AAA GUIDE DEVICE 22 EIFU · Class 2 · Implant

All models of Heli-FX EndoAnchor System (13)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00763000006624), received between Oct 23, 2017 and Oct 23, 2017 — classified as 1 malfunction.

The most frequently reported specific device problem is “Leak/Splash” (1 report).

1 other recall cover devices cleared under the same FDA submission (K171427, K182957); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Leak/Splash1

Patient problems

  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 23, 2017Leak/Splash; Leak/Splash

    HELI-FX APTUS ENDOANCHORS WERE IMPLANTED IN A PATIENT FOR THE TREATMENT FOR PREVENTION OF AORTIC NECK DILATATION IN ANOTHER MANUFACTURER¿S STENT GRAFT. IT WAS REPORTED THE FINAL ANGIOGRAM REVEALED A PROXIMAL TYPE I ENDOLEAK, A LOW-FLOW PROXIMAL TYPE I ENDOLEAK. THERE WAS NO INTERVENTION PERFORMED AND THE PROXIMAL TYPE I ENDOLEAK WAS UNRESOLVED. PER THE INVESTIGATOR THE IMPLANTATION OF THE HELI-FX APTUS ENDOANCHORS WAS NOT SUCCESSFUL. THE INVESTIGATOR INDICATED THE CAUSE OF THE EVENT WAS RELATED TO THE AAA. NO ADDITIONAL CLINICAL SEQUELAE WERE REPORTED AND THE PATIENT WILL BE MONITORED BY THE PHYSICIAN.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6968579 ↗

FDA clearance and classification

Cleared through Special 510(k) K182957 on Nov 21, 2018 (decision: Substantially Equivalent). Submitted by Medtronic Vascular, Inc. as “Heli-FX EndoAnchor System”. The FDA review took 28 days. FDA record ↗

Cleared through Special 510(k) K171427 on Jun 13, 2017 (decision: Substantially Equivalent). Submitted by Medtronic Vascular, Inc. as “Heli-FX Applier, Heli-FX Guide, Ancillary EndoAnchor Cassette”. The FDA review took 29 days. FDA record ↗

The FDA regulates product code OTD (endovascular suturing system) under 21 CFR 870.3460 as a Class II device. 21 CFR 870.3460 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K171427, K182957. One submission often covers many models, so check the product and lot details in each record.

  • Z-3227-2017 · Sep 13, 2017 · Terminated
    Medtronic Aptus Heli-FX Thoracic EndoAnchor System Heli-FX Guide 42 mm, REF HG-18-90-42, STERILE EO, Rx Only The Heli-FX EndoAnchor System is intended to provide fixation and sea

Common questions about the Heli-FX™ EndoAnchor™ System SG-64

Has the Heli-FX™ EndoAnchor™ System SG-64 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00763000006624), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.

What problems have been reported with the Heli-FX™ EndoAnchor™ System SG-64?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Oct 23, 2017. That report lists device problem “Leak/Splash” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Heli-FX™ EndoAnchor™ System SG-64?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Heli-FX™ EndoAnchor™ System SG-64 FDA approved?

It was cleared through Special 510(k) K171427 on Jun 13, 2017; its record lists 2 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the Heli-FX™ EndoAnchor™ System SG-64 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the Heli-FX™ EndoAnchor™ System SG-64, and is it still sold?

The FDA's device database lists Medtronic, Inc. as the company responsible for it (brand Heli-FX™ EndoAnchor™ System, model SG-64). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Endovascular suturing system devices

All Endovascular suturing system devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page