EDM 27637 (UDI 00763000030261)Recalls & reported problems
Medtronic Ps Medical, Inc. · EDM 27637 VCATH TRANS OD 4.9MM W/TROC · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00763000030261), received between May 11, 2023 and Apr 2, 2024 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Device Dislodged or Dislocated1
- Fluid/Blood Leak1
- Loose or Intermittent Connection1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- Unspecified Tissue Injury1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 2, 2024Fluid/Blood Leak; Fluid/Blood Leak
MEDTRONIC RECEIVED INFORMATION REGARDING AN EXTERNAL DRAINAGE AND MONITORING SYSTEM CATHETER. IT WAS REPORTED THAT DURING THE SURGERY OF VENTRICULOCENTESIS, WHEN USING NORMAL SALINE TO CHECK THE AIR TIGHTNESS, IT WAS FOUND THAT THE CATHETER LEAKED. THE CATHETER WAS REPLACED WITH A NEW ONE. THE PATIENT'S MEDICAL HISTORY WAS COMMUNICATING HYDROCEPHALUS CAUSED BY A CAR ACCIDENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19018553 ↗InjuryMay 11, 2023Loose or Intermittent Connection; Device Dislodged or Dislocated; Loose or Intermittent Connection; Device Dislodged or Dislocated
MEDTRONIC RECEIVED INFORMATION REGARDING AN EXTERNAL DRAINAGE AND MONITORING DEVICE. IT WAS REPORTED THAT THE INTERFACE BETWEEN THE VENTRICULAR DRAINAGE TUBE AND THE DRAINAGE BAG WAS LOOSE. UNDER GENERAL ANESTHESIA, THE PATIENT UNDERWENT 1. INTRACEREBRAL HEMATOMA EVACUATION, 2. SKULL DRILLING AND DRAINAGE, 3. SUBTEMPORAL DECOMPRESSION, 4. VENTRICULAR SHUNT, WITH INDWELLING VENTRICULAR DRAINAGE TUBE. ON 04-03, A CT EXAMINATION WAS PERFORMED AROUND 10:00. DURING THE EXAMINATION IN THE CT ROOM,THE VENTRICULAR DRAINAGE TUBE AND DRAINAGE DEVICE FELL OFF. THE CAUSE OF THE EVENT WAS REPORTED THE DRAINAGE TUBE CONNECTOR WAS NOT SECURE. THE PATIENT WAS RETURNED TO THE INTENSIVE CARE UNIT IMMEDIATELY, AND THE VENTRICULAR DRAINAGE TUBE WAS CLAMPED WITH HEMOSTATIC FORCEPS. THE PATIENT'S VITAL SIGNS, CONSCIOUSNESS, AND PUPILS WERE OBSERVED. AFTER INFORMING THE DOCTOR, THE VENTRICULAR DRAINAGE TUBE WAS REMOVED, AND THEN THE LUMBAR DRAINAGE TUBE WAS INDWELLED.
Patient problems: Unspecified Tissue Injury
MAUDE report 16910592 ↗
Other Device, monitoring, intracranial pressure devices
- Exacta™ 27666Medtronic Ps Medical, Inc. · Device, monitoring, intracranial pressure1 recall124 reports
- Exacta™ 46705Medtronic Ps Medical, Inc. · Device, monitoring, intracranial pressure1 recall117 reports
- CereLink™ 826850Integra Lifesciences Production Corporation · Device, monitoring, intracranial pressure1 recall2 deaths112 reports
- Duet® 46913Medtronic Ps Medical, Inc. · Device, monitoring, intracranial pressure1 recall58 reports
- CereLink™ 826851Integra Lifesciences Production Corporation · Device, monitoring, intracranial pressure96 reports
- Becker® 26040Medtronic Ps Medical, Inc. · Device, monitoring, intracranial pressure1 recall46 reports
- Becker® 46129Medtronic Ps Medical, Inc. · Device, monitoring, intracranial pressure1 recall29 reports
- Codman Microsensor® 826631Integra Lifesciences Production Corporation · Device, monitoring, intracranial pressure75 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page