NavLock 9736060Recalls & reported problems
Medtronic Navigation, Inc. · NAVLOCK 9736060 BLACK · Class 2
- Adverse event reports
- 11
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 00763000123178), received between Mar 13, 2019 and Dec 10, 2024 — classified as 11 malfunctions.
The most frequently reported specific device problem is “Material Integrity Problem” (5 reports).
1 other recall cover devices cleared under the same FDA submission (K182104); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Material Integrity Problem5
- Mechanical Problem3
- Device Sensing Problem2
- Imprecision2
- Use of Device Problem1
Patient problems
- No Patient Involvement5
- No Clinical Signs, Symptoms or Conditions3
- No Known Impact Or Consequence To Patient3
Recent adverse event reports
The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 10, 2024Mechanical Problem; Device Sensing Problem; Mechanical Problem; Device Sensing Problem
MEDTRONIC RECEIVED INFORMATION REGARDING A GUIDANCE SYSTEM BEING USED OUTSIDE OF A PROCEDURE. IT WAS REPORTED THAT THE BLACK TRACKER WAS HAVING ISSUES TRACKING AND APPEARED TO POTENTIALLY BE WARPED. THERE WAS NO PATIENT INVOLVEMENT. ADDITIONAL INFORMATION RECEIVED INDICATED THE TRACKING ISSUE WAS RESOLVED WHEN A DIFFERENT TRACKER WAS USED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20892854 ↗MalfunctionJun 5, 2023Imprecision; Use of Device Problem; Imprecision; Use of Device Problem
MEDTRONIC RECEIVED INFORMATION REGARDING A GUIDANCE SYSTEM BEING USED DURING A SPINAL PROCEDURE. IT WAS REPORTED THAT THE NAVIGATION WAS MEDIAL AND LATERAL FOR ALL THE INSTRUMENTS BUT ALL SCREWS WERE PLACED ACCURATELY, THE ARM WAS ACCURATE. THEY CHECKED NAVIGATION ACCURACY AND THE SNAPSHOT IMAGE AND ISSUE PERSISTED. THERE WAS NO DELAY AND NO IMPACT TO THE PATIENT OUTCOME. ADDITIONAL INFORMATION WAS RECEIVED STATING THAT THEY TESTED THE INSTRUMENTS AND THE NAVLOCKS WERE DAMAGED AND CAUSING THIS ISSUE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17066428 ↗MalfunctionJan 8, 2021Device Sensing Problem; Device Sensing Problem
ADDITIONAL INFORMATION RECEIVED FROM A MANUFACTURER REPRESENTATIVE REPORTED THAT THE ISSUE WAS DETERMINED TO BE THE CAMERA. THE CAMERA WAS REPLACED AND THE ISSUE WAS RESOLVED. ALL OF THE INSTRUMENTS WERE TESTED AND FOUND TO BE FUNCTIONING AS DESIGNED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11140769 ↗MalfunctionJun 5, 2020Imprecision; Imprecision
ADDITIONAL INFORMATION WAS RECEIVED STATING THAT THE NAVLOCKS WERE SHOWING ~3MM OFF. NO PHYSICAL ISSUES WERE SEEN WITH THE NAVLOCKS. TROUBLESHOOTING INVOLVED TAKING A SNAPSHOT AND CHECKING THE ANATOMY AND DIVET WITH THE PLANAR PROBE. EACH TIME A SNAPSHOT WAS TAKEN, THE OTHERS WOULD SHOWED ON, BUT THE BLUE AND BLACK SHOWED OFF. IT WAS THOUGHT THAT THE PATIENT REFERENCE FRAME BEING LOOSE WAS PART OF THE REASON THEY SHOWED OFF IN THIS CASE, BUT THEY HAVE ALSO HAD SHOWN OFF IN PREVIOUS PROCEDURES. THE PROBLEMS WITH THE NAVLOCKS WAS SPORADIC AND THEY WERE CURRENTLY BEING USED FOR CASES.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10123025 ↗MalfunctionOct 29, 2019Material Integrity Problem; Material Integrity Problem
MEDTRONIC RECEIVED INFORMATION REGARDING A GUIDANCE SYSTEM BEING USED DURING A SPINAL PROCEDURE. IT WAS REPORTED THAT THE BLACK TRACKER FUSED WITH THE LONG DRILL DURING THE CASE. THE CASE WAS COMPLETED WITH THE BLUE TRACKER. THERE WAS NO PATIENT HARM OR ADDITIONAL COMPLICATIONS REPORTED OR ANTICIPATED AS A RESULT OF THE EVENT. THERE WAS NO PATIENT HARM.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9252665 ↗MalfunctionAug 7, 2019Mechanical Problem; Mechanical Problem
MEDTRONIC RECEIVED INFORMATION FROM A MANUFACTURER REPRESENTATIVE (REP) REGARDING A GUIDANCE DEVICE BEING USED OUTSIDE OF A PROCEDURE. IT WAS REPORTED THAT THE BLACK NAVLOCK WOULD NOT ALLOW AN INSTRUMENT TO RUN THROUGH IT. THERE WAS NO PATIENT INVOLVED. THERE WERE NO ADDITIONAL COMPLICATIONS REPORTED OR ANTICIPATED AS A RESULT OF THE EVENT.
Patient problems: No Patient Involvement
MAUDE report 8869627 ↗MalfunctionJul 17, 2019Material Integrity Problem; Material Integrity Problem
MEDTRONIC RECEIVED INFORMATION FROM A HEALTHCARE PROFESSIONAL (HCP) VIA A MANUFACTURER REPRESENTATIVE (REP) REGARDING A GUIDANCE DEVICE BEING USED IN A SPINAL PROCEDURE. IT WAS REPORTED THAT THE LONG DRILL HAD VIBRATION AND A CHATTERING NOISE WITH THE BLACK NAVLOCK. ADDITIONAL INFORMATION RECEIVED INDICATED THAT THE REPLACEMENT WAS SENT AND THE NO ISSUES HAD OCCURRED. THE SYSTEM WAS PERFORMING AS INTENDED. THERE WAS NO PATIENT HARM. THERE WERE NO ADDITIONAL COMPLICATIONS REPORTED OR ANTICIPATED AS A RESULT OF THE EVENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8799978 ↗MalfunctionJul 12, 2019Material Integrity Problem; Material Integrity Problem
MEDTRONIC RECEIVED INFORMATION FROM A HEALTHCARE PROFESSIONAL (HCP) VIA A MANUFACTURER REPRESENTATIVE (REP) REGARDING A GUIDANCE DEVICE BEING USED IN A SPINAL PROCEDURE. IT WAS REPORTED THAT BOTH THE BLUE AND BLACK NAVLOCKS WERE STICKING TO THE INSTRUMENTS NOT ALLOWING THEM TO SPIN FREELY. THERE WAS NO PATIENT INVOLVEMENT. THERE WERE NO ADDITIONAL COMPLICATIONS REPORTED OR ANTICIPATED AS A RESULT OF THE EVENT.
Patient problems: No Patient Involvement
MAUDE report 8785105 ↗MalfunctionJul 2, 2019Mechanical Problem; Mechanical Problem
MEDTRONIC RECEIVED INFORMATION FROM A HEALTHCARE PROFESSIONAL (HCP) VIA A MANUFACTURER REPRESENTATIVE (REP) REGARDING A GUIDANCE DEVICE BEING USED IN A SPINAL PROCEDURE. IT WAS REPORTED THAT THE BLACK NAVLOCK GOT STUCK ON THE DRILL BIT. NO PATIENT WAS INVOLVED. THERE WERE NO ADDITIONAL COMPLICATIONS REPORTED OR ANTICIPATED AS A RESULT OF THE EVENT.
Patient problems: No Patient Involvement
MAUDE report 8753562 ↗MalfunctionMar 13, 2019Material Integrity Problem; Material Integrity Problem
MEDTRONIC RECEIVED INFORMATION THAT, WHILE OUTSIDE OF A PROCEDURE, THE INSTRUMENT TRACKER WAS DAMAGED WHILE NAVIGATING DRILL BITS. THERE WAS NO PATIENT PRESENT WHEN THIS ISSUE WAS IDENTIFIED. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Patient Involvement
MAUDE report 8418284 ↗MalfunctionMar 13, 2019Material Integrity Problem; Material Integrity Problem
MEDTRONIC RECEIVED INFORMATION THAT, WHILE OUTSIDE OF A PROCEDURE, THE INSTRUMENT TRACKER WAS DAMAGED WHILE NAVIGATING DRILL BITS. THERE WAS NO PATIENT PRESENT WHEN THIS ISSUE WAS IDENTIFIED. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Patient Involvement
MAUDE report 8418283 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K182104. One submission often covers many models, so check the product and lot details in each record.
- Z-1693-2020 · Aug 28, 2019 · TerminatedNavLock Tracker *** Rx Only
Other Orthopedic stereotaxic instrument devices
- REAL INTELLIGENCE ROB10024Smith & Nephew, Inc. · Orthopedic stereotaxic instrument1 recall924 reports
- NA 209063Mako Surgical Corp. · Orthopedic stereotaxic instrument2 recalls602 reports
- RESTORIS, RIO 212760Mako Surgical Corp. · Orthopedic stereotaxic instrument605 reports
- REAL INTELLIGENCE ROB10013Smith & Nephew, Inc. · Orthopedic stereotaxic instrument1 recall528 reports
- VELYS 4515-70-105Depuy (Ireland) · Orthopedic stereotaxic instrument578 reports
- VELYS 4515-70-106Depuy (Ireland) · Orthopedic stereotaxic instrument564 reports
- NA 209999Mako Surgical Corp. · Orthopedic stereotaxic instrument522 reports
- Mazor X System TPL0059-06Mazor Robotics Ltd · Orthopedic Stereotaxic Instrument2 recalls2 deaths392 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.