CD HORIZON® Fenestrated Screw Set 55750026540Recalls & reported problems

Medtronic Sofamor Danek, Inc. · FNS MAS 55750026540 STER CCM 6.5 X 40 · Class 2 · Implant

All models of CD HORIZON Fenestrated Screw Set (27)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
7
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 00763000148829), received between Oct 5, 2023 and Apr 16, 2026 — classified as 7 injuries, 1 malfunction.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 1 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 2 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break2
  • Leak/Splash2
  • Loosening of Implant Not Related to Bone-Ingrowth2
  • Adverse Event Without Identified Device or Use Problem1
  • Malposition of Device1
  • Migration1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • Device Embedded In Tissue or Plaque2
  • Extravasation1
  • Headache1
  • Pulmonary Embolism1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 16, 2026Loosening of Implant Not Related to Bone-Ingrowth

    INFORMATION WAS RECEIVED FROM THE HEALTH CARE PROFESSIONAL VIA A MANUFACTURER REPRESENTATIVE REGARDING A DEVICE USED FOR SPINAL THERAPY FOR ADULT SPINAL DEFORMITY AND TH10-S2 LEVEL IMPLANT WAS PERFORMED. IT WAS REPORTED THAT THE SCREW LOOSENED. THERE WERE NO PATIENT SYMPTOMS REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT. ADDITIONAL INFORMATION WAS RECEIVED AS PARTIAL REMOVAL WAS PERFORMED ON THE LEFT SIDE, TH10.11, L1.2 ADDITIONAL INFORMATION WAS RECEIVED ALL THE SCREWS WERE REMOVED FROM THE LEFT SIDE AND NO ADDITIONAL SURGERY IS NOT PLANNED AT THIS TIME.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24901731 ↗
  • InjuryApr 16, 2026Loosening of Implant Not Related to Bone-Ingrowth

    INFORMATION WAS RECEIVED FROM THE HEALTH CARE PROFESSIONAL VIA A MANUFACTURER REPRESENTATIVE REGARDING A DEVICE USED FOR SPINAL THERAPY FOR ADULT SPINAL DEFORMITY AND TH10-S2 LEVEL IMPLANT WAS PERFORMED. IT WAS REPORTED THAT THE SCREW LOOSENED. THERE WERE NO PATIENT SYMPTOMS REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT. ADDITIONAL INFORMATION WAS RECEIVED AS PARTIAL REMOVAL WAS PERFORMED ON THE LEFT SIDE, TH10.11, L1.2 ADDITIONAL INFORMATION WAS RECEIVED ALL THE SCREWS WERE REMOVED FROM THE LEFT SIDE AND NO ADDITIONAL SURGERY IS NOT PLANNED AT THIS TIME.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24901714 ↗
  • MalfunctionDec 16, 2025Migration; Migration

    INFORMATION WAS RECEIVED FROM A HEALTHCARE PROVIDER REGARDING A PATIENT HAVING TH12/L1/L2 TLIF TH11/L3 POSTERIOR SPINAL FUSION DUE TO OSTEOPOROTIC COMPRESSION FRACTURE. IT WAS REPORTED THAT POSTOPERATIVE CT REVEALED MEDIAL BREACH OF THE LEFT L2 SCREW AND CEMENT LEAKAGE INTO THE SPINAL CANAL. THE LEAKAGE IS CONSIDERED TO BE DUE TO THE SCREW DISLODGING INTO THE SPINAL CANAL. THE CEMENT LEAKAGE OCCURRED INTRAOPERATIVELY, AND IT WAS IDENTIFIED POSTOPERATIVELY. THERE WAS NO PATIENT SYMPTOMS REPORTED. THERE IS CURRENTLY NO PLAN TO EXPLANT THE SCREW. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.

    Patient problems: Extravasation

    MAUDE report 23814512 ↗
  • InjurySep 15, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    INFORMATION WAS RECEIVED FROM REGULATORY BODY (RB), HEALTHCARE PROVIDER VIA MANUFACTURER REPRESENTATIVE REGARDING PRODUCT USED IN SPINAL THERAPY FOR SPONDYLOLISTHESIS. IT WAS REPORTED THAT POST ARTHRODESIS THE ROD PLUG WAS OUT OF THE ROD AND SWIMMING IN THE BODY ON X-RAYS. THE PATIENT HAD HEADACHE AND REVISION SURGERY WAS PERFORMED TO EXPLANT THE DEVICES. THERE WERE NO FURTHER COMPLICATIONS OR SYMPTOMS REPORTED REGARDING THE EVENT.

    Patient problems: Headache

    MAUDE report 23053258 ↗
  • InjuryAug 22, 2025Leak/Splash; Leak/Splash

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING TRANSCUTANEOUS VERTEBRAL BODY FORMATION/TRANSCUTANEOUS POSTERIOR FUSION FOR OSTEOPOROTIC VERTEBRAL FRACTURE. IT WAS REPORTED THAT DURING CEMENT FI LLING OF THE CEMENT SCREW; CEMENT LEAKED TO THE SCREW HEAD. BECAUSE CEMENT LEAKED TO THE SCREW HEAD, THE CEMENT DELIVERY GUIDE TIP WAS RETAINED. THE PLANNED PERCUTANEOUS SURGERY ENDED UP NOT BEING ENTIRELY PERCUTANEOUS, RESULTING IN A SIGNIFICANTLY LARGER INCISION BEING MADE. THERE WAS A DELAY OF GREATER THAN 60 MINUTES IN THE OVERALL PROCEDURE TIME. A TOTAL OF 8 SCREWS WERE USED IN THE FIXED RANGE TH11/L3. ONLY THE RIGHT SIDE OF L2 LEAKED CEMENT ON THE SCREW HEAD SIDE. THE GUIDE TIP COULD BE REMOVED, BUT AFTER INSERTING THE ROD, THE SET SCREW COULD NOT BE INSERTED ON THE RIGHT SIDE OF L2. FOR THE RIGHT SIDE OF L2, THE SET SCREW INSTALLATION WAS ABANDONED. THERE WERE NO PATIENT SYMPTOMS REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22870449 ↗
  • InjuryJul 10, 2025Leak/Splash; Leak/Splash

    INFORMATION WAS RECEIVED FROM A HEALTHCARE PROVIDER REGARDING A PATIENT HAVING TRANSCUTANEOUS POSTERIOR FIXATION USING A CEMENT SCREW WITH 2A-2B FOR DISH FRACTURE AND COMPRESSION FRACTURE AND TRANSCUTANEOUS VERTEBROPLASTY USING BKP AT LEVELS T9-L2. IT WAS REPORTED THAT POST SURGERY, THE CEMENT LEAKED INTO THE VEIN AND FLOWED INTO THE PULMONARY ARTERY. THIS WAS DISCOVERED AFTER THE PROCEDURE, AND THE PATIENT WAS ASYMPTOMATIC AT THE TIME OF DISCOVERY. THERE WAS NO PATIENT SYMPTOM REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT. ADDITIONAL INFORMATION WAS RECEIVED FROM THE MANUFACTURER REPRESENTATIVE THAT THE MIXER HAD NO MALFUNCTION. REGARDING THE KITS AND SCREWS, THERE WAS A SMALL POSSIBILITY THAT THEY MAY HAVE CAUSED THE CEMENT LEAKAGE BUT THIS WAS NOT CONFIRMED. THERE WAS NO CHANGE IN THE PATIENT'S CONDITION AND NO ADDITIONAL TREATMENT OR PROCEDURE IS BEING PERFORMED AS A RESULT OF THIS EVENT. BUT THE PATIENT WAS FOUND TO HAVE STOMACH CANCER WHILE HE WAS IN THE HOSPITAL (WAITING FOR RECOVERY), AND THAT HE WOULD PERFORM A GASTRIC CANCER OPERATION WHICH WAS UNRELATED TO THIS EVENT. THEREFORE, IT IS UNKNOWN WHETHER HE HAS RECOVERED OR NOT. ADDITIONAL INFORM

    Patient problems: Pulmonary Embolism

    MAUDE report 22470297 ↗
  • InjuryOct 5, 2023Break; Break

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING A SPINAL THERAPY. IT WAS REPORTED THAT BOTH S1 SCREWS (RIGHT AND LEFT) WERE BROKEN. THE PRODUCTS WERE EXPLANTED BUT THE TIPS REMAINED INSIDE THE PATIENT. IT WAS A REVISION CASE. THE PATIENT HAD PSEUDARTHROSIS AND A SCREW WAS IN THE CANAL FOR THIS REASON, THE PATIENT WAS OPERATED. THERE WAS NO PATIENT SYMPTOM REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 17874956 ↗
  • InjuryOct 5, 2023Break; Malposition of Device; Break; Malposition of Device

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING A SPINAL THERAPY. IT WAS REPORTED THAT BOTH S1 SCREWS (RIGHT AND LEFT) WERE BROKEN. THE PRODUCTS WERE EXPLANTED BUT THE TIPS REMAINED INSIDE THE PATIENT. IT WAS A REVISION CASE. THE PATIENT HAD PSEUDARTHROSIS AND A SCREW WAS IN THE CANAL FOR THIS REASON, THE PATIENT WAS OPERATED. THERE WAS NO PATIENT SYMPTOM REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 17874906 ↗