CD HORIZON® Fenestrated Screw Set 55750027550Recalls & reported problems

Medtronic Sofamor Danek, Inc. · FNS MAS 55750027550 STER CCM 7.5 X 50 · Class 2 · Implant

All models of CD HORIZON Fenestrated Screw Set (27)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00763000149185), received between Jun 16, 2026 and Jun 16, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Mechanics Altered” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Mechanics Altered1

Patient problems

  • Extravasation1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 16, 2026Mechanics Altered

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING POSTERIOR FIXAT ION PROCEDURE AT L1¿L3. THE PROCEDURE WAS PERFORMED AS A REVISION SURGERY FOLLOWING A PRIOR BKP AT L2 FOR OSTEOPOROTIC COMPRESSION FRACTURE. IT WAS REPORTED THAT DURING THE PROCEDURE, A GAP BETWEEN THE LOCKING OUTER SLEEVE AND THE TAB EXTENDER CAP WAS NOTICED. THE PHYSICIAN WAS CONSULTED AND INDICATED THAT IT SHOULD BE FINE AS THE BUTTON COULD NOT BE PRESSED. HOWEVER, CEMENT LEAKAGE WAS CONFIRMED UNDER IMAGING. THE SCREW WAS REMOVED AND INSERTED AGAIN TO ADDRESS THE ISSUE. PRIOR REVISION SURGERY WAS PERFORMED FOR INSTABILITY OF THE ADJACENT VERTEBRAL BODIES, DESCRIBED AS ADJACENT SEGMENT DISEASE, AND NOT DUE TO A CEMENT PRODUCT ISSUE. IT WAS ALSO CONFIRMED THAT NO ISSUE WAS IDENTIFIED WITH THE CEMENT ITSELF AND THAT THE REPORTED CEMENT LEAKAGE DURING THE CURRENT PROCEDURE WAS ATTRIBUTED TO THE FENESTRATED SCREW ISSUE, SPECIFICALLY THE GAP BETWEEN THE LOCKING OUTER SLEEVE AND TAB EXTENDER CAP. THERE WAS NO PATIENT SYMPTOM REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.

    Patient problems: Extravasation

    MAUDE report 25516228 ↗

Other Thoracolumbosacral pedicle screw system devices

All Thoracolumbosacral pedicle screw system devices →