SimuForm™ 7800RR26 (UDI 00763000271176)Recalls & reported problems

Medtronic, Inc. · RING 7800RR26 SIMUFORM SR 26MM US · Class 2 · Implant

Adverse event reports
12
Deaths reported
0
Injuries reported
12
Recalls naming it
0

Summary

The FDA's MAUDE database contains 12 adverse event reports that list this exact device (DI 00763000271176), received between Nov 4, 2020 and Dec 12, 2025 — classified as 12 injuries.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (8 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 2 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Device Problem Information8
  • Inadequacy of Device Shape and/or Size3
  • Adverse Event Without Identified Device or Use Problem2
  • Patient Device Interaction Problem2

Patient problems

  • Insufficient Information9
  • Heart Block2
  • No Information1

Recent adverse event reports

The 12 most recent of 12 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 12, 2025Patient Device Interaction Problem; Patient Device Interaction Problem

    IT WAS REPORTED THAT 6 DAYS POST IMPLANT OF THIS 26MM MITRAL ANNULOPLASTY HEART RING, A PERMANENT PACEMAKER WAS IMPLANTED. THE REASON FOR THE PERMANENT PACEMAKER WAS REPORTED AS COMPLETE HEART BLOCK (CHB). NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Heart Block

    MAUDE report 23788063 ↗
  • InjuryNov 22, 2024Patient Device Interaction Problem; Patient Device Interaction Problem

    IT WAS REPORTED THAT POST IMPLANT OF THIS MITRAL ANNULOPLASTY RING, A PERMANENT PACEMAKER WAS IMPLANTED. THE REASON FOR THE PERMANENT PACEMAKER WAS REPORTED AS COMPLETE HEART BLOCK. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Heart Block

    MAUDE report 20758330 ↗
  • InjuryNov 12, 2024Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT 1 YEARS AND 7 MONTHS POST IMPLANT OF THIS 26 MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED AND REPLACED WITH A 29 MM MITRAL BIOPROSTHETIC VALVE. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 20663542 ↗
  • InjuryAug 23, 2024Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT 1 MONTH POST IMPLANT OF THIS 26MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED AND REPLACED WITH A DIFFERENT MANUFACTURER'S MECHANICAL VALVE. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 20054379 ↗
  • InjuryMay 21, 2024Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT DURING THE IMPLANT OF THIS 26MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED. THE REASON FOR THE R EPLACEMENT WAS NOT REPORTED. IT WAS STATED THAT "NO ACTIVE HEART VALVE WAS IMPLANTED IN THE PATIENT". NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 19359797 ↗
  • InjuryJul 1, 2022Inadequacy of Device Shape and/or Size; Insufficient Device Problem Information; Inadequacy of Device Shape and/or Size; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT DURING THE IMPLANT OF THIS 26MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED AND REPLACED WITH AN UNKNOWN PRODUCT. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 14885048 ↗
  • InjuryJun 14, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    MEDTRONIC RECEIVED INFORMATION THAT DURING THE IMPLANT OF THIS 26MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED AND REPLACED WITH AN UNKNOWN PRODUCT. THE REASON FOR THE REPLACEMENT WAS REPORTED TO BE DUE TO THE NATIVE VALVES PATHOLOGY ULTIMATELY BEING TOO COMPLEX FOR REPAIR. IT WAS REPORTED THAT THERE WAS NO ISSUE WITH THE ANNULOPLASTY RING. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 14684853 ↗
  • InjuryMay 4, 2022Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT DURING THE IMPLANT OF THIS 26MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED AND REPLACED WITH A 31MM MITRAL BIOPROSTHETIC VALVE. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED.  NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 14278026 ↗
  • InjuryMar 29, 2022Inadequacy of Device Shape and/or Size; Inadequacy of Device Shape and/or Size

    MEDTRONIC RECEIVED INFORMATION THAT DURING THE IMPLANT OF THIS 26MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED AND REPLACED WITH A 24MM RING OF THE SAME MODEL. THE REASON FOR THE REPLACEMENT WAS THAT THE 26MM RING WAS TOO BIG.  NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 13943704 ↗
  • InjuryNov 8, 2021Inadequacy of Device Shape and/or Size; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Inadequacy of Device Shape and/or Size; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT DURING THE IMPLANT OF THIS 28MM MITRAL ANNULOPLASTY RING, IT WAS EXPLANTED AND REPLACED WITH A 2 6MM MITRAL ANNULOPLASTY RING. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 12770646 ↗
  • InjuryAug 30, 2021Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT DURING THE IMPLANT OF THIS 26MM MITRAL ANNULOPLASTY BAND, IT WAS EXPLANTED AND REPLACED WITH A 28MM MITRAL ANNULOPLASTY BAND. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 12383958 ↗
  • InjuryNov 4, 2020Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT THIS PATIENT UNDERWENT MITRAL VALVE SURGERY DUE TO SEVERE MITRAL VALVE REGURGITATION RELATED TO BACTERIAL ENDOCARDITIS. THE PATIENT'S NATIVE MITRAL VALVE HAD AN ABSCESS AND A PERFORATION ON THE P1 LEAFLET. THE SURGEON REPAIRED THE LEAFLETS AND SUPPORTED THE VALVE WITH A 26MM FLEXIBLE ANNULOPLASTY BAND. THERE IS NO MENTION IN THE OPERATIVE REPORT ABOUT THIS 26MM ANNULOPLASTY RING, BUT A DEVICE IDENTIFICATION CARD FOR THIS SERIAL NUMBER WAS SUBMITTED TO MEDTRONIC AND INDICATED THAT THE PRODUCT WAS "EXPLANTED". IT IS UNCLEAR IF THIS RING WAS ATTEMPTED PRIOR TO THE IMPLANT OF THE 26MM BAND. THE PATIENT TOLERATED THE PROCEDURE WELL AND NO ADVERSE PATIENT EFFECTS WERE NOTED.

    Patient problems: No Information

    MAUDE report 10786031 ↗

Other RING, ANNULOPLASTY devices

All RING, ANNULOPLASTY devices →