Axium™ Detachable Coil System PC-3-8-HELIXRecalls & reported problems
Micro Therapeutics, Inc. · COIL PC-3-8-HELIX V12 · Class 2 · Implant
All models of Axium Detachable Coil System (69)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00763000488925), received between Nov 29, 2023 and Nov 29, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
1 other recall cover devices cleared under the same FDA submission (K203432); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
- Physical Resistance/Sticking1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 29, 2023Break; Physical Resistance/Sticking; Break; Physical Resistance/Sticking
MEDTRONIC RECEIVED A REPORT THAT AXIUM COIL PREPPED AND HYDRATED VERTICALLY PER FDA INSTRUCTION. DUE TO NON-TAPERED COIL SHEATH OF P C-3-8-HELIX A SMALL GAP EXISTS BETWEEN AXIUM COIL SHEATH AND ECHELON 10 MICROCATHETER ALLOWING THE COIL TO PREMATURELY BREAK CAUSING RESISTANCE ENOUGH FOR THE PHYSICIAN NOT BE ABLE TO ADVANCE COIL( KNOWN ISSUE). SECOND PC-3-8-HELIX PREPPED AND HYDRATED VERTICALLY PER FDA INSTRUCTION AND INSERTED INTO ECHELON 10 MICROCATHETER BUT SAME OCCURRENCE AS FIRST AXIUM DUE TO GAP CAUSED BY NON-TAPERED SHEATH CAUSING RESISTANCE AND UNABLE TO ADVANCE. INSERTED AN AXIUM PRIME 3-8-HX-ES WITH A TAPERED COILING SHEATH AND THE COIL DEPLOYED WITHOUT ISSUE. IT WAS REPORTED THERE WAS COIL RESISTANCE/STUCK IN SHEATH. THE REPORTED DEVICE AND ANY ACCESSORY DEVICES WERE PREPARED AS INDICATED IN THE INSTRUCTIONS FOR USE (IFU). NO PATIENT SYMPTOMS OR FURTHER COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT. THE PATIENT WAS UNDERGOING SPINAL EMBOLIZATION. IT WAS NOTED THE PATIENT'S BLOOD FLOW WAS NORMAL AND VESSEL TORTUOSITY WAS MINIMAL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18233609 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K203432. One submission often covers many models, so check the product and lot details in each record.
- Z-1261-2022 · Apr 27, 2022 · Open, ClassifiedAXIUM DETACHABLE COIL SYSTEM REF QC-4-12-HELIX; Axium Detachable Coil System REF QC-10-30-3D;
Other DEVICE, NEUROVASCULAR EMBOLIZATION devices
- POD RBYPODJ60-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION355 reports
- Penumbra System SCH1Penumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION295 reports
- RUBY Coil RBY4C0860-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION276 reports
- Smart Coil 400SMTHXSFT0208Penumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION165 reports
- Penumbra System RH1-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION154 reports
- Optima Coil System OPTI0208CSS10Balt USA LLC · Device, Neurovascular Embolization3 recalls3 reports
- POD RBYPOD6-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION148 reports
- POD RBYPODJ30-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION132 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page