VISUALASE 9735542 (UDI 00763000521370)Recalls & reported problems
Medtronic Navigation, Inc. · SYSTEM 9735542 15W VISUALASE · Class 2
All models of Visualase (25)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00763000521370), received between Feb 13, 2025 and Feb 11, 2026 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Infusion or Flow Problem” (2 reports).
1 other recall cover devices cleared under the same FDA submission (K211269); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Infusion or Flow Problem2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 11, 2026Infusion or Flow Problem
MEDTRONIC RECEIVED INFORMATION REGARDING A THERMAL THERAPY SYSTEM BEING USED DURING A SOFT TISSUE ABLATION (NEURO) PROCEDURE. IT WAS REPORTED THAT THE SYSTEM'S COOLING FLUID PUMP MALFUNCTIONED IN A CASE. THE PROCEDURE WAS APPROXIMATELY 80% COMPLETE, AT WHICH TIME THE PUMP STOPPED MOVING AND BEGAN MAKING A "SQUEALING" NOISE AS IF A GEAR WAS JAMMED INSIDE. THE MANUFACTURER REPRESENTATIVE (REP) TRIED REVERSING DIRECTIONS AS WELL AS DIFFERENT POWER OUTLETS, BUT THE ISSUE PERSISTED. THE REP WAS ABLE TO MANUALLY MOVE A BEARING IN THE PUMP AND GET IT WORKING AGAIN FOR APPROXIMATELY 30 SECONDS, BUT THEN IT STOPPED MOVING AGAIN. THE REP WAS UNABLE TO GET IT WORKING AT THAT POINT. THE SURGEON THEN OPTED TO ABANDON FURTHER USE OF THE SYSTEM. THERE WAS A REPORTED DELAY TO THE PROCEDURE OF LESS THAN 1 HOUR DUE TO THIS ISSUE. THERE WAS NO REPORTED IMPACT ON PATIENT OUTCOME.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24316272 ↗MalfunctionFeb 13, 2025Infusion or Flow Problem; Infusion or Flow Problem
MEDTRONIC RECEIVED INFORMATION REGARDING A THERMAL THERAPY SYSTEM BEING USED OUTSIDE OF A PROCEDURE. IT WAS REPORTED THAT WHEN INSTALLING THE SYSTEM, THE WATER PUMP DID NOT WORK. IT HAD POWER, BUT WHEN THE LEVER WAS PULLED DOWN, NOTHING HAPPENED. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21377223 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K211269. One submission often covers many models, so check the product and lot details in each record.
- Z-0244-2023 · Oct 14, 2022 · Open, ClassifiedVisualase Cooled Laser Applicator System (VCLAS) 9735560 .4MM CORE FIBER 10MM TIP product. Used to necrotize or coagulate soft tissue by physicians in minimally invasive surgical
Other Neurosurgical laser with MR thermography devices
- Visualase 9735560Medtronic Navigation, Inc. · Neurosurgical laser with MR thermography1 recall59 reports
- Visualase 9735560Medtronic Navigation, Inc. · Neurosurgical laser with MR thermography1 recall4 reports
- Visualase 9735559Medtronic Navigation, Inc. · Neurosurgical laser with MR thermography1 recall3 reports
- Visualase 9735560Medtronic Navigation, Inc. · Neurosurgical laser with MR thermography1 recall3 reports
- Visualase 9735559Medtronic Navigation, Inc. · Neurosurgical laser with MR thermography1 recall0 reports
- Visualase 9735560Medtronic Navigation, Inc. · Neurosurgical laser with MR thermography44 reports
- Visualase 9735559Medtronic Navigation, Inc. · Neurosurgical laser with MR thermography15 reports
- Visualase 9735542Medtronic Navigation, Inc. · Neurosurgical laser with MR thermography15 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page