Axium™ Detachable Coil System QC-3-6-3DRecalls & reported problems

Micro Therapeutics, Inc. · COIL QC-3-6-3D V14 · Class 2 · Implant

All models of Axium Detachable Coil System (69)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00763000845797), received between Mar 5, 2026 and Mar 5, 2026 — classified as 1 injury.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component1
  • Separation Failure1

Patient problems

  • Intracranial Hemorrhage1
  • Ruptured Aneurysm1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 5, 2026Separation Failure; Detachment of Device or Device Component

    MEDTRONIC RECEIVED A REPORT THAT DURING THE PROCEDURE THE AXIUM COIL WOULD NOT DETACH. THE PATIENT WAS UNDERGOING SURGERY FOR TREATMENT OF A SACCULAR, RUPTURED ANTERIOR COMMUNICATING ARTERY (ACOM) ANEURYSM WITH A MAX DIAMETER OF 2.4 MM AND A 1.5 MM NECK DIAMETER. IT WAS NOTED THAT THE PATIENT'S BLOOD FLOW WAS NORMAL AND VESSEL TORTUOSITY WAS SEVERE. IT WAS REPORTED THAT THE PATIENT WAS BEING TREATED FOR A SUBARACHNOID HEMORRHAGE FROM AN ACOM ANEURYSM. DURING THE PROCEDURE, THE COIL WAS SEATED PROPERLY IN THE ANEURYSM WITHOUT ANY TROUBLE, HOWEVER, IT WOULD NOT DETACH USING THE DETACHER. THE COIL WAS MANUALLY BROKEN AT THE DETACHMENT ZONE, HOWEVER, WOULD NOT ACTUALLY DETACH. THE PHYSICIAN WAS ABLE TO PULL THE ENTIRE COIL INTO THE SL 10 CATHETER, HOWEVER, ONCE IT WAS IN THE CATHETER IT DETACHED. THE PHYSICIAN WAS ABLE TO PULL THE CATHETER WITH THE COIL INSIDE OUT OF THE PATIENT WITHOUT ANY TROUBLE. THE PATIENT¿S TORTUOSITY WAS NOTED AS SEVERE, HOWEVER, THE PHYSICIAN DID NOT BEND OR USE EXCESSIVE PUSH TO GET THE COIL TO THE ANEURYSM. AFTER THE COIL AND CATHETER WERE REMOVED FROM THE PATIENT, THE PATIENT RE-RUPTURED ON THE TABLE. THE PHYSICIAN WAS ABLE TO GO BACK UP AND PLACE A FEW AXIO

    Patient problems: Intracranial Hemorrhage; Ruptured Aneurysm

    MAUDE report 24523666 ↗

Other DEVICE, NEUROVASCULAR EMBOLIZATION devices

All DEVICE, NEUROVASCULAR EMBOLIZATION devices →