Skip to content

IMPRA® ePTFE Vascular Grafts F5006CRecalls & reported problems

Bard Peripheral Vascular, Inc. · IMPRA® ePTFE Vascular Graft, Carboflo® Flex Carbon-Lined, 6 mm x 50 cm · Class 2 · Implant

All models of IMPRA ePTFE Vascular Grafts (52)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00801741021350), received between May 20, 2021 and Mar 10, 2026 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Fluid/Blood Leak” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fluid/Blood Leak2
  • Leak/Splash1
  • Material Split, Cut or Torn1
  • Peeled/Delaminated1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 10, 2026Fluid/Blood Leak; Leak/Splash; Peeled/Delaminated; Material Split, Cut or Torn

    ON (B)(6) 2026, A PATIENT UNDERWENT A SURGICAL GRAFT PLACEMENT PROCEDURE USING A CARBOFLO DEVICE. IT WAS REPORTED THAT DURING THE PROCEDURE, THE RING ON THE GRAFT ALLEGEDLY FELL OFF, CAUSING THE BLOOD TO LEAK FROM THE GRAFT. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24554738 ↗
  • MalfunctionMay 20, 2021Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT DURING A PROCEDURE, THE DEVICE ALLEGEDLY LEAKED. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11853714 ↗

Other PROSTHESIS, VASCULAR GRAFT, OF LESS THEN 6MM DIAMETER devices

All PROSTHESIS, VASCULAR GRAFT, OF LESS THEN 6MM DIAMETER devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page