Bardex® Lubri-Sil® I.C. All-Silicone Foley Catheter 1758SI22Recalls & reported problems
C. R. Bard, Inc. · Bardex® Lubri-Sil® I.C. All-Silicone Coated 5 cc Foley Catheter · Class 2
All models of Bardex Lubri-Sil I.C. All-Silicone Foley Catheter (26)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00801741025259), received between Jul 25, 2018 and Apr 25, 2023 — classified as 2 injuries, 1 malfunction.
The most frequently reported specific device problem is “Complete Blockage” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Complete Blockage1
- Deflation Problem1
- Partial Blockage1
- Patient-Device Incompatibility1
Patient problems
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- Hemorrhage/Blood Loss/Bleeding1
- No Consequences Or Impact To Patient1
- No Known Impact Or Consequence To Patient1
- Patient Problem/Medical Problem1
- Urinary Tract Infection1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryApr 25, 2023Deflation Problem; Deflation Problem
IT WAS REPORTED THAT THE FOLEY CATHETER WAS NOT DRAINING. DOCTOR OF MEDICINE ATTEMPTED TO REMOVE CATHETER AFTER BALLOON DEFLATION BUT WAS UNABLE. DOCTOR OF MEDICINE CUT BALLOON FILLING PORT AND BALLOON STAYED INFLATED. DOCTOR OF MEDICINE REMOVED CATHETER WITH INFLATED BALLOON. DOCTOR OF MEDICINE WENT BACK IN WITH CYSTOSCOPE TO ASSURE HOMEOSTASIS AND THEN REPLACED NEW CATHETER WITHOUT DIFFICULTY.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 16806942 ↗InjuryNov 21, 2018Patient-Device Incompatibility; Patient-Device Incompatibility; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT EXPERIENCED SELF LIMITED BLEEDING AND A URINARY TRACT INFECTION AFTER INSERTION OF THE 22 FR CATHETER. THE PATIENT WAS TREATED WITH A PRESCRIPTION ANTIBIOTIC FOR THE UTI IN THE EMERGENCY ROOM.
Patient problems: Hemorrhage/Blood Loss/Bleeding; Patient Problem/Medical Problem; Urinary Tract Infection
MAUDE report 8096805 ↗MalfunctionJul 25, 2018Partial Blockage; Complete Blockage; Partial Blockage
IT WAS REPORTED THAT THE CATHETER BECAME BLOCKED AND CLOGGED DURING USE. NO MEDICAL INTERVENTION WAS REPORTED.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 7719882 ↗
Other CATHETER, RETENTION TYPE, BALLOON devices
- Bardex® All-Silicone Foley Catheter 165816C. R. Bard, Inc. · CATHETER, RETENTION TYPE, BALLOON512 reports
- Bardex® Lubri-Sil® All-Silicone Foley Catheter 175816C. R. Bard, Inc. · CATHETER, RETENTION TYPE, BALLOON476 reports
- Bardex® Lubri-Sil® I.C. All-Silicone Foley Catheter 1758SI16C. R. Bard, Inc. · CATHETER, RETENTION TYPE, BALLOON1 death383 reports
- Bardex® Lubri-Sil® All-Silicone Foley Catheter 175812C. R. Bard, Inc. · CATHETER, RETENTION TYPE, BALLOON234 reports
- Bardex® Lubri-Sil® All-Silicone Temp Sensing Foley Catheter 119216MC. R. Bard, Inc. · CATHETER, RETENTION TYPE, BALLOON167 reports
- Bardex® Lubri-Sil® All-Silicone Foley Catheter 175814C. R. Bard, Inc. · CATHETER, RETENTION TYPE, BALLOON153 reports
- Bardex® All-Silicone Foley Catheter 165812C. R. Bard, Inc. · CATHETER, RETENTION TYPE, BALLOON151 reports
- SureStep™ Foley Tray System Bard® Lubri-Sil® Foley Catheter Tray A942216C. R. Bard, Inc. · CATHETER, RETENTION TYPE, BALLOON2 recalls46 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗