PowerPICC Catheter 3175335Recalls & reported problems
Bard Access Systems, Inc. · PowerPICC Catheter 5F Single-Lumen Polyurethane Catheter Radiology Basic Tray (135 cm Nitinol Guidewire) · Class 2 · Implant
All models of PowerPICC Catheter (33)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 18
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 18 adverse event reports that list this exact device (DI 00801741027697), received between Feb 24, 2022 and Sep 6, 2024 — classified as 1 injury, 17 malfunctions.
The most frequently reported specific device problem is “Fluid/Blood Leak” (15 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Fluid/Blood Leak15
- Material Deformation4
- Defective Component2
- Difficult or Delayed Separation1
Patient problems
- No Clinical Signs, Symptoms or Conditions17
- Foreign Body In Patient2
Recent adverse event reports
The 18 most recent of 18 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 6, 2024Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED BY CUSTOMER THAT HUB WAS LEAKING AT THE HUB WHEN FLUID WAS FLUSHED THROUGH THE NEEDLESS CONNECTOR CAP. NO OTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20156228 ↗MalfunctionApr 6, 2023Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED BY THE CUSTOMER THAT A DEFECTIVE SINGLE PICC LINE WAS RECOVERED. THE PATIENT HAD TO HAVE THE PICC LINE REPLACED WITH DOUBLE LUMEN THAT DID NOT LEAK. ADDITIONAL INFORMATION RECEIVED ON 3/20/2023: A SL 5FR PICC LINE WAS INSERTED AND FOUND TO BE BACKING UP WITH BLOOD AND LEAKING AT THE HUB/NEEDLELESS CONNECTOR. THE CATHETER WAS SECURED WITH STATLOCK. THERE WAS NO BREAK. PATIENT RECEIVED ROCEPHIN INFUSIONS THROUGH THE PICC AS AN OUTPATIENT. CLINICIAN STATES THE PICC WAS NOTED TO BARELY LEAK WITH FLUSHING SALINE, BUT NOT WITH INFUSION OF ROCEPHIN FOR SOME TIME. THE IR DOCTOR WAS NOTIFIED AND CLEARED THE LINE FOR USE. THE CLINICIAN STATES THAT FROM THEIR UNDERSTANDING, SEVERAL WEEKS LATER AFTER RETURNING HOME FROM HIS DAILY ROCEPHIN INFUSION, THE PATIENT CALLED, STATING THAT THE PICC WAS LEAKING AND BACKED UP WITH BLOOD. PATIENT WAS INSTRUCTED TO RETURN TO THE CATH LAB AND THE SL PICC WAS REMOVED AND A NEW DL PICC WAS PLACED. THERE WERE NO SIGNS OR SYMPTOMS OR OTHER COMPLICATIONS. THE EVENT DID NOT INVOLVE AN URGENT OR LIFE-THREATENING MEDICAL SITUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16691388 ↗MalfunctionApr 6, 2023Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED BY THE CUSTOMER THAT A DEFECTIVE SINGLE PICC LINE WAS RECOVERED. THE PATIENT HAD TO HAVE THE PICC LINE REPLACED WITH DOUBLE LUMEN THAT DID NOT LEAK. ADDITIONAL INFORMATION RECEIVED 3/20/2023: SINGLE LUMEN 5F PICC LINE INSERTED, FOUND TO BE LEAKING AT HUB/NEEDLELESS CONNECTOR. THE CATHETER WAS SECURED WITH STATLOCK. THERE WAS NO BREAK IN THE CATHETER; THE NURSE NOTICED IT LEAKED AT THE HUB WHEN FLUSHED. THERE WAS NO CLINICAL DELAY IN TREATMENT BUT THE PATIENT DID HAVE ANOTHER PROCEDURE TO EXCHANGE THE PICC FOR A DL PICC. NO SIGNS OR SYMPTOMS OR OTHER COMPLICATIONS OCCURRED. ANCEF WAS INFUSED THROUGH THE PICC BUT THE CLINICIAN REPORTS THE PICC WAS NOTED TO LEAK JUST WITH FLUSHING WITH SALINE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16691386 ↗MalfunctionMar 22, 2023Defective Component; Material Deformation; Defective Component; Material Deformation
IT WAS REPORTED BY THE CUSTOMER THERE WAS LEAKING AT THE HUB CONNECTION BETWEEN PICC AND CONNECTOR. ADDITIONAL INFORMATION RECEIVED ON 3/15/2023: CUSTOMER REPORTED 2 PICCS WERE USED WITH MINIMAL PROBLEM ASIDE FROM THE LEAKING AT THE HUB THEN "LIKELY REMOVED AFTER TREATMENT WAS COMPLETE." THIS REPORT ADDRESSES THE FIRST DEVICE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16595362 ↗MalfunctionMar 22, 2023Defective Component; Material Deformation; Defective Component; Material Deformation
IT WAS REPORTED BY THE CUSTOMER THERE WAS LEAKING AT THE HUB CONNECTION BETWEEN PICC AND CONNECTOR. ADDITIONAL INFORMATION RECEIVED 3/15/2023: CUSTOMER REPORTED 2 PICCS WERE USED WITH MINIMAL PROBLEM ASIDE FROM THE LEAKING AT THE HUB THEN "LIKELY REMOVED AFTER TREATMENT WAS COMPLETE." THIS REPORT ADDRESSES THE SECOND DEVICE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16595359 ↗MalfunctionSep 29, 2022Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED "TWO PICCS INSERTED AT ONE OF OUR OTHER SITES, THAT CAME BACK TO US LEAKING. THESE WERE SINGLE LUMEN, INSERTED (B)(6), LEAKS NOTICED (B)(6) AND EXCHANGES WERE DONE." ADD INFO RCVD (B)(6) 2022: IN THE REPORTED CASES, PATIENTS HAD TO UNDERGO A PICC EXCHANGE PROCEDURE. THIS REPORT ADDRESSES THE SECOND DEVICE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15503264 ↗MalfunctionSep 29, 2022Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED "TWO PICCS INSERTED AT ONE OF OUR OTHER SITES, THAT CAME BACK TO US LEAKING. THESE WERE SINGLE LUMEN, INSERTED SEPT 1, LEAKS NOTICED SEPT 7 AND EXCHANGES WERE DONE." ADD INFO RCVD 09/16/2022: IN THE REPORTED CASES, PATIENTS HAD TO UNDERGO A PICC EXCHANGE PROCEDURE. THIS REPORT ADDRESSES THE FIRST DEVICE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15503243 ↗MalfunctionSep 27, 2022Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED "THERE HAS BEEN A LEAKING LINE IDENTIFIED".
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15493170 ↗MalfunctionJul 29, 2022Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED BY THE CUSTOMER "PICC LINE IS LEAKING BETWEEN THE END OF THE PICC AND THE CLAVE" WHAT TYPE OF CATHETER SECUREMENT WAS UTILIZED? STAT-LOK DATE OF OCCURRENCE: (B)(6) 2022. PLACEMENT DATE: (B)(6) 2022. EXPLANT DATE: (B)(6) 2022. WAS THERE ANY PATIENT HARM REPORTED: NO.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15136313 ↗MalfunctionJul 20, 2022Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED "PICC LEAKING." ADDITIONAL INFORMATION RECEIVED 07/12/2022: A DETAILED DESCRIPTION OF THE EVENT: PICC LINE IS LEAKING BETWEEN THE END OF THE PICC AND THE CLAVE WHAT TYPE OF CATHETER SECUREMENT WAS UTILIZED? STAT-LOK DATE OF OCCURRENCE: (B)(6) 2022 PLACEMENT DATE: (B)(6) 2022. EXPLANT DATE: PICC STILL IN PLACE WAS THERE ANY PATIENT HARM REPORTED: NO.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15069948 ↗MalfunctionJul 20, 2022Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED "PICC LEAKING¿. ADDITIONAL INFORMATION RECEIVED 07/12/2022: A DETAILED DESCRIPTION OF THE EVENT: PICC LINE IS LEAKING BETWEEN THE END OF THE PICC AND THE CLAVE WHAT TYPE OF CATHETER SECUREMENT WAS UTILIZED? STAT-LOK DATE OF OCCURRENCE: (B)(6) 2022. PLACEMENT DATE: (B)(6) 2022 EXPLANT DATE: PICC WAS LEFT IN PLACE BECAUSE IT WAS ONLY NEEDED FOR 1 MORE DAY WAS THERE ANY PATIENT HARM REPORTED: NO.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15069897 ↗MalfunctionJul 20, 2022Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED "PICC LEAKING." ADDITIONAL INFORMATION RECEIVED 07/12/2022: A DETAILED DESCRIPTION OF THE EVENT: PICC LINE IS LEAKING BETWEEN THE END OF THE PICC AND THE CLAVE. WHAT TYPE OF CATHETER SECUREMENT WAS UTILIZED? STAT-LOK DATE OF OCCURRENCE: (B)(6) 2022. PLACEMENT DATE: (B)(6) 2022. EXPLANT DATE: (B)(6) 2022. WAS THERE ANY PATIENT HARM REPORTED: NO.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15069884 ↗MalfunctionJul 15, 2022Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED BY THE CUSTOMER, "POWER PICCS INSERTED IN IR BY DIFFERENT INSERTERS ARE LEAKING AT THE HUB WHEN FLUID IS FLUSHED THROUGH THE NEEDLESS CONNECTOR CAP, THE BAXTER ONELINK. WHEN THE CAP WAS APPLIED TO A DIFFERENT CATHETER, THERE WAS NO LEAKING."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15029230 ↗MalfunctionJul 13, 2022Fluid/Blood Leak; Material Deformation; Fluid/Blood Leak; Material Deformation
IT WAS REPORTED BY THE CUSTOMER LEAKING PICC. IT WAS STATED THE PICC WAS CHECKED AND IT DIDN'T SEEM TO BE CRACKED. IT'S LIKE THERE IS A PROBLEM WITH THE THREADING.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15004583 ↗MalfunctionApr 22, 2022Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED "COMPLAINT FROM COMPLEX CARE OF CRACKING CATHETER HUB WHEN CONNECTED TO DEAD END CAP RESULT IN PATIENT NEEDING CATHETER REPLACEMENT. "
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14189480 ↗MalfunctionApr 22, 2022Fluid/Blood Leak; Material Deformation; Fluid/Blood Leak; Material Deformation
IT WAS REPORTED "COMPLAINTS FROM COMPLEX CARE OF CRACKING CATHETER HUB WHEN CONNECTED TO DEAD END CAP RESULT IN PATIENT NEEDING CATHETER REPLACEMENT."
Patient problems: Foreign Body In Patient; No Clinical Signs, Symptoms or Conditions
MAUDE report 14189477 ↗MalfunctionApr 22, 2022Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED "CATHETER PLACED IN IR FOUND LEAKING AT CONNECTION." NO OTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14189211 ↗InjuryFeb 24, 2022Difficult or Delayed Separation; Difficult or Delayed Separation
IT WAS REPORTED "WHEN TRYING TO SPLIT PEEL AWAY RED PART BROKE OFF AND REST OF PEEL AWAY MIGRATED INTO THE VESSEL." NO OTHER INFORMATION WAS PROVIDED.
Patient problems: Foreign Body In Patient
MAUDE report 13596241 ↗
Other Catheter,intravascular,therapeutic,long-term greater than 30 days devices
- Groshong NXT ClearVue Catheter 7617405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 deaths1,708 reports
- Groshong NXT ClearVue Catheter 7655405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 deaths1,536 reports
- PowerPICC Catheter 3174118Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days1 recall402 reports
- L-Cath™ S/L PICC S/L 26GA (1.9F) x 30cmArgon Medical Devices, Inc. · Catheter,Intravascular,Therapeutic,Long-Term Greater Than 30 Days2 recalls245 reports
- PowerPICC SOLO2 Catheter 1194108DBard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 recalls216 reports
- Broviac 0600520Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days1 recall265 reports
- Groshong® Catheter 7717405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days279 reports
- PowerPICC Catheter 3275118Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days272 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page