PowerPICC SOLO2 Catheter with Sherlock Tip Location System (TLS) Stylet 9295108Recalls & reported problems
Bard Access Systems, Inc. · DOT PowerPICC, Solo, · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00801741028649), received between Aug 17, 2018 and Oct 5, 2018 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
- Difficult to Remove1
- Fitting Problem1
- Material Deformation1
Patient problems
- No Known Impact Or Consequence To Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryOct 5, 2018Break; Fitting Problem
IT WAS REPORTED THAT THE PICC PLACEMENT OCCURRED ON (B)(6) AND A WIRE FRAGMENT WAS FOUND UNDER X-RAY ON (B)(6). IT WAS STATED THERE WERE NO FRAGMENTS FOUND WITH THE INITIAL X-RAYS. FOUR DAYS LATER , FRAGMENTS OF A WIRE WERE FOUND UNDER X-RAY. THE WIRE WAS FOUND ZIG -ZAGGING UNDER THE PULMONARY ARTERY. IT WAS STATED THAT THE FACILITY IS NOT 100% SURE IF IT IS FROM THE PICC INSERTION SINCE THE PICC NURSE DIDN¿T OBSERVE ANYTHING UNUSUAL. ACCORDING TO THE PICC NURSE, THE PICC PROCEDURE WAS TYPICAL AND THE PATIENT WAS NOT CONSIDERED A DIFFICULT STICK. THE PATIENT WAS NOT IN ANY PAIN. THE FRAGMENT WAS NOT REMOVED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7939654 ↗MalfunctionAug 17, 2018Difficult to Remove; Material Deformation
IT WAS REPORTED THAT THE CATHETER WAS VERY DIFFICULT TO REMOVE AFTER AN ATTEMPT TO PLACE IT. IT WAS STATED ONCE THE PHYSICIAN HAD REMOVED IT, A KNOT IN THE CATHETER WAS NOTED. NO ADDITIONAL INFORMATION HAS BEEN REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7794749 ↗
Other Catheter,intravascular,therapeutic,long-term greater than 30 days devices
- Groshong NXT ClearVue Catheter 7617405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 deaths1,708 reports
- Groshong NXT ClearVue Catheter 7655405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 deaths1,536 reports
- PowerPICC Catheter 3174118Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days1 recall402 reports
- L-Cath™ S/L PICC S/L 26GA (1.9F) x 30cmArgon Medical Devices, Inc. · Catheter,Intravascular,Therapeutic,Long-Term Greater Than 30 Days2 recalls245 reports
- PowerPICC SOLO2 Catheter 1194108DBard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 recalls216 reports
- Broviac 0600520Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days1 recall265 reports
- Groshong® Catheter 7717405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days279 reports
- PowerPICC Catheter 3275118Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days272 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page