Bard® Touchless® Plus Unisex Pre-Lubricated Vinyl Coude Urethral Catheter Kit 4A7116Recalls & reported problems
C. R. Bard, Inc. · Bard® Touchless® Plus Unisex Pre-Lubricated Vinyl Coude Urethral Catheter Kit · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00801741046469), received between Jul 3, 2019 and Aug 18, 2022 — classified as 1 injury, 5 malfunctions.
The most frequently reported specific device problem is “Structural Problem” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Structural Problem2
- Biocompatibility1
- Deformation Due to Compressive Stress1
- Difficult to Insert1
- Fluid/Blood Leak1
- Material Split, Cut or Torn1
- Misassembled1
- Sharp Edges1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- No Consequences Or Impact To Patient2
- No Known Impact Or Consequence To Patient1
- Urinary Tract Infection1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 18, 2022Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED THAT THE PATIENT WAS EXPERIENCING ISSUES WITH SOME OF THE TOUCHLESS CATHETER. THE PATIENT HAD WASTED 5 OUT OF THE LAST ORDER DUE TO INSERTION AND LEAKAGE PROBLEMS, GOT AUTHORIZATION TO REPLACE THOSE 5.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15251615 ↗MalfunctionMay 20, 2021Material Split, Cut or Torn; Material Split, Cut or Torn
IT WAS REPORTED THAT THE TEN OF THE TOUCH LESS CATHETERS WAS HAVING A PINHOLE AND RESULTED IN LEAK. ALSO STATED THAT THE CATHETER TUBING WAS KINKED AT THE POINT WHERE THE CATHETER WAS INSERTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11857961 ↗MalfunctionMay 20, 2021Deformation Due to Compressive Stress; Deformation Due to Compressive Stress
IT WAS REPORTED THAT TEN TOUCHLESS CATHETERS WERE HAVING A PINHOLE AND RESULTED IN LEAKAGE. IT WAS ALSO STATED THAT THE CATHETER TUBING WAS KINKED TO THE POINT WHERE INSERTION OF CATHETER WAS NOT POSSIBLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11853612 ↗MalfunctionSep 2, 2020Difficult to Insert; Structural Problem; Sharp Edges; Sharp Edges
IT WAS REPORTED THAT THE NEW TOUCHLESS PLUS INTERMITTENT CATHETER SYSTEMS WERE BEING DIFFICULT TO INSERT AS THE TIP WAS TOO POINTED.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Consequences Or Impact To Patient
MAUDE report 10482447 ↗InjuryMay 18, 2020Biocompatibility; Biocompatibility; Therapeutic or Diagnostic Output Failure
IT WAS REPORTED THAT THE CATHETERS DID NOT WORK WELL AND THE PATIENT EXPERIENCED A URINARY TRACT INFECTION WHEN USING THEM.
Patient problems: Urinary Tract Infection
MAUDE report 10065377 ↗MalfunctionJul 3, 2019Misassembled; Misassembled; Structural Problem
IT WAS REPORTED THAT THE CURVE OF THE COUDE CATHETER TIP WAS "VERY SLIGHT" AND AS A RESULT THE PATIENT DID NOT KNOW IF THE TIP WAS UP OR DOWN. THE PATIENT WAS USING A MARKER TO INDICATE WHERE THE CORRECT DIRECTION FOR INSERTION. NO MEDICAL INTERVENTION WAS REPORTED.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 8757903 ↗
Other Tray, catheterization, sterile urethral, with or without catheter (kit) devices
- Bard® Touchless® Plus Unisex Pre-Lubricated Vinyl Urethral Catheter Kit 4A5144C. R. Bard, Inc. · Tray, catheterization, sterile urethral, with or without catheter (kit)170 reports
- Bard® Touchless® Plus Unisex Pre-Lubricated Rubber Urethral Catheter Kit 4A7044C. R. Bard, Inc. · Tray, catheterization, sterile urethral, with or without catheter (kit)54 reports
- Dover 3450LFCardinal Health, Inc. · Tray, catheterization, sterile urethral, with or without catheter (kit)1 recall3 reports
- Dover 3450Cardinal Health, Inc. · Tray, Catheterization, Sterile Urethral, With Or Without Catheter (Kit)1 recall1 report
- Dover 3410Cardinal Health, Inc. · Tray, Catheterization, Sterile Urethral, With Or Without Catheter (Kit)1 recall0 reports
- Dover 8887600784Cardinal Health, Inc. · Tray, Catheterization, Sterile Urethral, With Or Without Catheter (Kit)1 recall0 reports
- Dover 8887600776Cardinal Health, Inc. · Tray, Catheterization, Sterile Urethral, With Or Without Catheter (Kit)1 recall0 reports
- Dover 3408Cardinal Health 200, LLC · Tray, catheterization, sterile urethral, with or without catheter (kit)1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page