Closed Wound Suction 0072360Recalls & reported problems

C. R. Bard, Inc. · 100cc Silicone Closed Wound Suction Evacuator Kit, 100cc Silicone Evacuator with Anti-Reflux Valve, Hubless Silicone Flat Drain 7mm Wide, 20cm Long, 3/4 Perforated Drain with Trocar, X-Ray Opaque · Class 1

All models of Closed Wound Suction (24)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00801741050008), received between Dec 19, 2022 and Dec 21, 2022 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Component Misassembled” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Component Misassembled1
  • Device Contamination with Chemical or Other Material1
  • Material Fragmentation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 21, 2022Material Fragmentation; Device Contamination with Chemical or Other Material; Material Fragmentation; Device Contamination with Chemical or Other Material

    IT WAS REPORTED THAT THERE WAS A PRESENCE OF A SILICONE STOPPER INSIDE THE TUBING OF SUCTION EVACUATOR WHICH WAS PROXIMAL TO THE TROCAR. THE INTERNAL WHITE PART WAS PERFORATED ONLY ON THE TWO-THIRD INSTEAD OF WHOLE. THEREFORE, IT WAS IMPOSSIBLE TO USE ON CRANIOTOMY FOR TOO LONG AS IT WAS NOT PERFORATED THE FULL LENGTH.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16022890 ↗
  • MalfunctionDec 19, 2022Component Misassembled; Component Misassembled

    IT WAS REPORTED THAT THERE WAS A PRESENCE OF A SILICONE STOPPER INSIDE THE TUBING OF SUCTION EVACUATOR WHICH WAS PROXIMAL TO THE TROCAR. THE INTERNAL WHITE PART WAS PERFORATED ONLY ON THE TWO-THIRD INSTEAD OF WHOLE. THEREFORE, IT WAS IMPOSSIBLE TO USE ON CRANIOTOMY FOR TOO LONG AS IT WAS NOT PERFORATED THE FULL LENGTH.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16003905 ↗

FDA clearance and classification

The FDA regulates product code GCY (apparatus, suction, single patient use, portable, nonpowered) under 21 CFR 878.4680 as a Class I device. 21 CFR 878.4680 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Closed Wound Suction 0072360

Has the Closed Wound Suction 0072360 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00801741050008), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Closed Wound Suction 0072360?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between Dec 19, 2022 and Dec 21, 2022. In those reports, the most common specific device problems are “Component Misassembled” (1), “Device Contamination with Chemical or Other Material” (1) and “Material Fragmentation” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Closed Wound Suction 0072360?

None of the reports are classified as deaths, 0 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Closed Wound Suction 0072360 FDA approved?

Devices of this type (product code GCY) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by C. R. Bard, Inc.

Who makes the Closed Wound Suction 0072360, and is it still sold?

The FDA's device database lists C. R. Bard, Inc. as the company responsible for it (brand Closed Wound Suction, model 0072360). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other APPARATUS, SUCTION, SINGLE PATIENT USE, PORTABLE, NONPOWERED devices

All APPARATUS, SUCTION, SINGLE PATIENT USE, PORTABLE, NONPOWERED devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page