VascuTrak® V1850150Recalls & reported problems

Bard Peripheral Vascular, Inc. · VascuTrak® PTA Dilatation Catheter 5 mm x 150 mm, 140 cm catheter · Class 2

All models of VascuTrak (20)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00801741061691), received between Sep 21, 2018 and Feb 20, 2026 — classified as 2 injuries, 3 malfunctions.

The most frequently reported specific device problem is “Deflation Problem” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Deflation Problem2
  • Material Rupture2
  • Break1
  • Device Damaged Prior to Use1
  • Device Misassembled During Manufacturing /Shipping1
  • Difficult to Remove1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • Needle Stick/Puncture2
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 20, 2026Difficult to Remove; Material Rupture

    ON (B)(6) 2026, A PATIENT UNDERWENT A PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) PROCEDURE USING THE VASCUTRAK BALLOON CATHETER. DURING THE PROCEDURE, THE BALLOON CATHETER ALLEGEDLY RUPTURED. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24398223 ↗
  • MalfunctionDec 19, 2022Break; Device Damaged Prior to Use; Device Misassembled During Manufacturing /Shipping; Break; Device Damaged Prior to Use; Device Misassembled During Manufacturing /Shipping

    IT WAS REPORTED THAT DURING THE PREPARATION OF AN ANGIOPLASTY PROCEDURE, HALF BROKEN GUIDEWIRE WAS ALLEGEDLY OBSERVED ON THE BALLOON TIP. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO PATIENT CONTACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16002907 ↗
  • MalfunctionMar 15, 2021Material Rupture; Material Rupture

    IT WAS REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE THROUGH THE FEMORAL ARTERY, THE BALLOON ALLEGEDLY FAILED TO INFLATE, UPON RADIOGRAPHIC INSPECTION FLUID LEAK WAS IDENTIFIED. THE BALLOON WAS WITHDRAWN AND WAS NOTED TO HAVE A RUPTURE. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11479275 ↗
  • InjuryDec 16, 2019Deflation Problem; Deflation Problem

    IT WAS REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE OF A SLIGHTLY CALCIFIED LESION IN THE POPLITEAL ARTERY, THE PTA BALLOON ALLEGEDLY WOULD NOT DEFLATE. IT WAS FURTHER REPORTED THAT THE PHYSICIAN USED A NEEDLE STICK TO PERCUTANEOUSLY DEFLATE THE BALLOON. A STENT WAS PLACED AT THE PUNCTURE SITE. PATENCY WAS REPORTEDLY RESTORED POST PROCEDURE. THERE WERE NO FURTHER REPORTED COMPLICATIONS.

    Patient problems: Needle Stick/Puncture

    MAUDE report 9477166 ↗
  • InjurySep 21, 2018Deflation Problem; Deflation Problem

    IT WAS REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE IN THE FEMORAL ARTERY, THE PTA BALLOON ALLEGEDLY WOULD NOT DEFLATE. A NEEDLE WAS INSERTED THROUGH THE SKIN TO DEFLATE THE BALLOON. ANOTHER DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: Needle Stick/Puncture; No Consequences Or Impact To Patient

    MAUDE report 7898606 ↗

Other Catheter, percutaneous, cutting/scoring devices

All Catheter, percutaneous, cutting/scoring devices →