Hohn Catheter for Central Venous Placement 0600730Recalls & reported problems
Bard Access Systems, Inc. · Hohn Percutaneous 7F Dual-Lumen Catheter Basic Kit · Class 2 · Implant
All models of Hohn Catheter for Central Venous Placement (3)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00801741074462), received between Jan 20, 2016 and Nov 10, 2023 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Fluid/Blood Leak” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Fluid/Blood Leak2
- Bent1
- Break1
- Deformation Due to Compressive Stress1
- Failure to Advance1
- Material Puncture/Hole1
- No Flow1
Patient problems
- No Known Impact Or Consequence To Patient4
- No Consequences Or Impact To Patient2
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 10, 2023Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED VIA MEDWATCH PATIENT'S IV TACRO LINE BEEPING "OCCLUDED" FREQUENTLY. RN ATTEMPTED TO FLUSH WHITE LUMEN WHERE MEDICATION WAS INFUSING AND LUMEN RUPTURED, CAUSING SMALL TEAR IN RUBBER AT END OF LUMEN NEAR THE CAP. LINE CLAMPED AND LABELED "DO NOT USE" AND ALL MEDICATION SWITCHED TO RED LUMEN. NOCTURNIST MADE AWARE OF LINE FAILURE. PATIENT HAD CVL REPLACED IN CVIR. NO OTHER INFORMATION PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18113356 ↗MalfunctionAug 29, 2019Break; No Flow
IT WAS REPORTED THAT DURING THE PROCESS OF OBTAINING BLOOD FROM THE CATHETER, THE WARD NURSE WHILE TRYING TO ASPIRATE BLOOD FROM THE CATHETER WITH THE WHITE HUB, THERE WAS NO BLOOD FLOW, AS WELL AS UNABLE TO FLUSH THE LUMEN. ATTEMPT WAS MADE TO UNBLOCK THE CATHETER BY USING THE ¿PUSH AND WITHDRAW¿ TECHNIQUES OF TRYING TO UNBLOCK THE CATHETER WITH 10MLS LUER LOCK SYRINGE, HOWEVER, WAS UNSUCCESSFUL. THE STAFF THEN TRIED USING A 5MLS LUER LOCK SYRINGE (AS IN THE SAME MANNER), TRIED TO UNBLOCK ¿ ONLY MANAGED TO FLUSH IN 1ML. THERE WAS NO BACKFLOW AND STAFF TRIED TO FLUSH THE WHITE LUMEN CATHETER, AND THE CATHETER BROKE.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 8947749 ↗MalfunctionAug 29, 2019Fluid/Blood Leak; Material Puncture/Hole; Fluid/Blood Leak
IT WAS REPORTED THAT WARD STAFF WAS UNCLAMPING THE WHITE HUB OF THE CATHETER AND WHILE TRYING TO FLUSH THE CATHETER, NOTICED A SMALL PUNCTURE HOLE AT THE WHITE HUB OF THE CATHETER ON THE SPOT OF WHERE THE CLAMP WAS PLACED.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 8947053 ↗MalfunctionAug 24, 2018Failure to Advance; Deformation Due to Compressive Stress
IT WAS REPORTED THAT THE DOCTOR MANAGED TO GAIN ACCESS TO A VEIN WITH A NEEDLE BUT WAS UNABLE TO PUSH THE GUIDEWIRE THROUGH. REPORTEDLY THE GUIDEWIRE WAS JUST NOT ABLE TO GO THROUGH THE VEIN AND KINKED. THE DOCTOR HAD TO OPENED A NEW GUIDEWIRE AND THEN WAS ABLE TO COMPLETE THE PROCEDURE SUCCESSFULLY.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7813921 ↗MalfunctionJan 20, 2016Bent
IT WAS REPORTED THAT WHEN TRYING TO INTRODUCE THE CATHETER, IT DID NOT PASS AND BECAUSE OF THAT THE GUIDE WAS BENT. THUS, THE CATHETER WAS NOT PLACED. THE PRODUCT SPECIALIST AND THE MARKETING MANAGER WERE PRESENT DURING THE PROCEDURE. (B)(6) 2015 - THE RETURNED WIRE HAS A BROKEN WELD TIP.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 5381761 ↗
Other Catheter,intravascular,therapeutic,long-term greater than 30 days devices
- Groshong NXT ClearVue Catheter 7617405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 deaths1,708 reports
- Groshong NXT ClearVue Catheter 7655405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 deaths1,536 reports
- PowerPICC Catheter 3174118Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days1 recall402 reports
- L-Cath™ S/L PICC S/L 26GA (1.9F) x 30cmArgon Medical Devices, Inc. · Catheter,Intravascular,Therapeutic,Long-Term Greater Than 30 Days2 recalls245 reports
- PowerPICC SOLO2 Catheter 1194108DBard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 recalls216 reports
- Broviac 0600520Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days1 recall265 reports
- Groshong® Catheter 7717405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days279 reports
- PowerPICC Catheter 3275118Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days272 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page