PowerPICC CK000539Recalls & reported problems
Bard Access Systems, Inc. · Catheter Placement Kit · Class 2 · Implant
All models of PowerPICC (118)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00801741105197), received between Jul 21, 2017 and Jul 28, 2017 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Malposition of Device” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Malposition of Device2
- Device Inoperable1
Patient problems
- No Information1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 28, 2017Malposition of Device
FACILITY REPORTED THAT PICC WAS PLACED ON (B)(6) 2017, IN THE RIGHT BASILICA VEIN. PLACEMENT WAS "UNEVENTFUL", 5FR TRIPLE LUMEN PICC, 38 CM LONG WITH 2 CM EXPOSED. PICC PLACEMENT VERIFIED WITH 3CG. TWELVE DAYS POST PLACEMENT NURSE WAS INFORMED THAT THE PICC "STOPPED WORKING" AND CATHFLO DID NOT HELP. PICC WAS STILL 2 CM OUT. CHEST X-RAY WAS DONE TO CHECK FOR MALPOSITIONING. THE READING WAS PROXIMAL SVC. AN X-RAY OF THE ARM WAS DONE TO SEE IF IT WAS A GOOD IDEA FOR THE PICC TEAM TO REPLACE. A SINGLE VIEW IS OBTAINED, CENTERED OVER THE MID AND LATERAL RIGHT CHEST INCLUDING THE RIGHT ARM. PICC LINE IS SEEN, TIP EXTENDING TO THE MID SUPERIOR VENA CAVA. THERE IS A MODERATE LOOP IN THE MEDIAL BICEP REGION WITH AN 'S' SHAPED CURVATURE OF APPROXIMATELY 4CM. THIS COULD ACCOUNT FOR AN 8 CM DISCREPANCY OF LENGTH FROM THE EXPECTED POSITION. THERE IS NO KINKING OR CATHETER FRAGMENTATION. WITH THE PREVIOUS PICC MALPOSITION IN 12-24 HOURS AFTER REPLACEMENT, INTERVENTIONAL RADIOLOGY DECIDED TO PLACE A NEW PICC.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6750321 ↗MalfunctionJul 21, 2017Device Inoperable; Malposition of Device
FACILITY REPORTED TO THE SALES REP THAT THE PICC MALPOSITIONED AND STOPPED WORKING AFTER 12 DAYS AND REQUIRED REPLACEMENT. NO OTHER INFORMATION WAS PROVIDED, BUT HAS BEEN REQUESTED.
Patient problems: No Information
MAUDE report 6733671 ↗
Other Catheter,intravascular,therapeutic,long-term greater than 30 days devices
- Groshong NXT ClearVue Catheter 7617405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 deaths1,708 reports
- Groshong NXT ClearVue Catheter 7655405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 deaths1,536 reports
- PowerPICC Catheter 3174118Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days1 recall402 reports
- L-Cath™ S/L PICC S/L 26GA (1.9F) x 30cmArgon Medical Devices, Inc. · Catheter,Intravascular,Therapeutic,Long-Term Greater Than 30 Days2 recalls245 reports
- PowerPICC SOLO2 Catheter 1194108DBard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 recalls216 reports
- Broviac 0600520Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days1 recall265 reports
- Groshong® Catheter 7717405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days279 reports
- PowerPICC® Catheters 1174108DBard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days1 recall222 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page