COVERA AVFM10060Recalls & reported problems

Angiomed GmbH & Co. Medizintechnik KG · COVERA™ Vascular Covered Stent 10 mm x 60 mm (80 cm delivery catheter) (flared) · Class 3 · Implant

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
14
Deaths reported
0
Injuries reported
11
Recalls naming it
1

Summary

The FDA's MAUDE database contains 14 adverse event reports that list this exact device (DI 00801741106590), received between Apr 8, 2020 and Oct 9, 2025 — classified as 11 injuries, 3 malfunctions.

The most frequently reported specific device problem is “Material Deformation” (6 reports).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 2 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Dec 22, 2022Open, Classified

    An increase in the reported complaint rate for inability to deploy was identified and related to poor slide block bonding.

    Z-1108-2023 · Root cause: Unknown/Undetermined by firm · FDA record ↗

Most reported problems

Device problems

  • Material Deformation6
  • Adverse Event Without Identified Device or Use Problem4
  • Obstruction of Flow3
  • Difficult to Remove1
  • Misfire1
  • Packaging Problem1
  • Positioning Failure1

Patient problems

  • Stenosis5
  • No Clinical Signs, Symptoms or Conditions4
  • Pain3
  • Restenosis3
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Numbness1
  • Occlusion1
  • Swelling/ Edema1

Recent adverse event reports

The 14 most recent of 14 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 9, 2025Positioning Failure; Difficult to Remove; Positioning Failure; Difficult to Remove

    ON (B)(6) 2025, A PATIENT UNDERWENT A STENT GRAFT PLACEMENT PROCEDURE USING COVERA VASCULAR COVERED STENT. DURING THE PROCEDURE COVERA STENT WAS DEPLOYED IN A FISTULA. IT WAS REPORTED THAT, THE STENT SEEMED TO FULLY DEPLOY BUT ALLEGEDLY FAILED TO RELEASE FROM THE DELIVERY SYSTEM. IT WAS FURTHER REPORTED THAT THE STENT WAS REMOVED FORCEFULLY FROM THE PATIENT. REPORTEDLY, THE PATIENT EXPERIENCED PAIN DURING REMOVAL OF DEVICE. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THE CURRENT STATUS OF THE PATIENT WAS UNKNOWN.

    Patient problems: Pain

    MAUDE report 23252709 ↗
  • InjuryAug 14, 2025Material Deformation; Material Deformation

    A PATIENT UNDERWENT A COVERA STENT PLACEMENT SURGERY ONE MONTH AGO. DURING FOLLOW-UP IT WAS FOUND THAT THE POST DECLOT AND ACCESS WAS HYPER PULSATILE AND INSIDE THE STENT IS CRUSHED. THE CURRENT STATUS OF THE PATIENT WAS UNKNOWN.

    Patient problems: Restenosis

    MAUDE report 22802298 ↗
  • InjuryAug 14, 2025Material Deformation; Material Deformation

    A PATIENT UNDERWENT A COVERA STENT PLACEMENT, INSIDE THE STENT IS ANOTHER CRUSHED STENT THAT IS CRUSHED. THE CURRENT STATUS OF THE PATIENT WAS UNKNOWN.

    Patient problems: Restenosis

    MAUDE report 22802296 ↗
  • MalfunctionJul 31, 2024Packaging Problem; Packaging Problem

    IT WAS REPORTED THAT PRIOR TO A STENT GRAFT PLACEMENT PROCEDURE, THE BOX OF THE DEVICE HAD ALLEGEDLY OPENED ON ONE END AND TAPED SHUT. THERE WAS NO PATIENT CONTACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19879474 ↗
  • InjuryFeb 22, 2023Material Deformation; Material Deformation

    IT WAS REPORTED THAT FIVE DAYS POST STENT PLACEMENT, THE STENT ALLEGEDLY GOT BUCKLED. IT WAS FURTHER REPORTED THAT ADDITIONAL INTERVENTION WAS REQUIRED BY PLACING ADDITIONAL STENTS FOR THE REPORTED STENT BUCKLING. THE PATIENT IS REPORTED TO BE STABLE.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; No Clinical Signs, Symptoms or Conditions

    MAUDE report 16416073 ↗
  • MalfunctionSep 3, 2022Misfire; Misfire

    IT WAS REPORTED THAT DURING A STENT GRAFT PLACEMENT PROCEDURE, THE STENT ALLEGEDLY HAD PARTIAL DEPLOYMENT. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15353525 ↗
  • InjurySep 30, 2021Obstruction of Flow; Material Deformation; Obstruction of Flow; Material Deformation

    IT WAS REPORTED THAT A FEW DAYS POST STENT PLACEMENT PROCEDURE IN THE LUE AV FISTULA, BLOOD FLOW WAS ALLEGEDLY NOTED TO BE OBSTRUCTED. IT WAS FURTHER REPORTED THAT THE PATIENT'S UPPER ARM WAS RED, SWOLLEN AND WAS PAINFUL. UPON EXAMINATION, THE STENT WAS FOUND TO BE COLLAPSED. THE CURRENT STATUS OF THE PATIENT IS UNKNOWN.

    Patient problems: Pain; Swelling/ Edema

    MAUDE report 12555449 ↗
  • InjurySep 1, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THROUGH THE RESULTS OF A CLINICAL TRIAL, THAT APPROXIMATELY FOUR MONTHS POST INDEX PROCEDURE, STENOSIS IN TARGET LESION WAS OBSERVED AND STANDARD PTA WAS USED TO SUCCESSFULLY TREAT THE TARGET LESION. THE CURRENT STATUS OF THE SUBJECT WAS NOT PROVIDED.

    Patient problems: Stenosis

    MAUDE report 12405450 ↗
  • InjuryAug 31, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THROUGH THE RESULTS OF A CLINICAL TRIAL, THAT APPROXIMATELY TEN MONTHS POST INDEX PROCEDURE, STENOSIS IN TARGET LESION WAS OBSERVED AND A STANDARD PTA WAS USED TO SUCCESSFULLY TREAT THE TARGET LESION. THE CURRENT STATUS OF THE SUBJECT WAS NOT PROVIDED.

    Patient problems: Stenosis

    MAUDE report 12390193 ↗
  • InjuryAug 30, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THROUGH THE RESULTS OF A CLINICAL TRIAL, THAT APPROXIMATELY ONE YEAR POST INDEX PROCEDURE, STENOSIS IN TARGET LESION WAS OBSERVED AND STANDARD PTA WAS USED TO SUCCESSFULLY TREAT THE TARGET LESION. THE CURRENT STATUS OF THE SUBJECT WAS NOT PROVIDED.

    Patient problems: Stenosis

    MAUDE report 12382004 ↗
  • InjuryMay 26, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THROUGH THE RESULTS OF A CLINICAL TRIAL, THAT APPROXIMATELY THREE MONTHS SIX DAYS POST INDEX PROCEDURE, STENOSIS IN TARGET LESION WAS OBSERVED. STANDARD PTA AND BARE METAL WERE USED TO SUCCESSFULLY TREAT THE TARGET LESION. THE CURRENT PATIENT STATUS WAS NOT PROVIDED.

    Patient problems: Restenosis

    MAUDE report 11883124 ↗
  • MalfunctionNov 10, 2020Material Deformation; Material Deformation

    IT WAS REPORTED THAT DURING A COVERED STENT PLACEMENT PROCEDURE IN A PRE-DILATED VESSEL TO BRIDGE TWO STENT GRAFTS, THE COVERED STENT COMPRESSED. IT WAS FURTHER REPORTED THAT THE PHYSICIAN DEPLOYED ANOTHER COVERED STENT TO FILL THE GAP. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10815740 ↗
  • InjuryApr 20, 2020Obstruction of Flow; Material Deformation; Obstruction of Flow; Material Deformation

    IT WAS REPORTED THAT APPROXIMATELY SEVERAL DAYS POST COVERED STENT PLACEMENT THE NON FLARED END OF THE STENT WAS FOUND ALLEGEDLY FOLDED OCCLUDING THE VESSEL. PATIENT STATUS WAS NOT PROVIDED.

    Patient problems: Occlusion; Stenosis

    MAUDE report 9979806 ↗
  • InjuryApr 8, 2020Obstruction of Flow; Obstruction of Flow

    IT WAS REPORTED THROUGH THE RESULTS OF A CLINICAL TRIAL THAT APPROXIMATELY FOUR MONTHS POST INDEX PROCEDURE, STENOSIS IN THE TARGET LESION WAS IDENTIFIED AND STANDARD PTA AND THROMBECTOMY WERE PERFORMED. APPROXIMATELY FIVE MONTHS AND ONE YEAR SIX MONTHS POST INDEX PROCEDURE, TARGET LESION STENOSIS WAS IDENTIFIED AND RE-INTERVENTION WAS PERFORMED, INCLUDING PTA. APPROXIMATELY TWO YEARS SEVEN MONTHS POST INDEX PROCEDURE, AN AV FISTULA ANEURYSM WAS IDENTIFIED. THE PATIENT WAS ADMITTED TO THE HOSPITAL AND THE AV FISTULA WAS RESECTED AND AN AV GRAFT WAS PLACED. THE PATIENT COMPLETED THE STUDY.

    Patient problems: Numbness; Pain; Stenosis

    MAUDE report 9936055 ↗

Other System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment devices

All System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.