COVERARecalls & reported problems across all models
Angiomed GmbH & Co. Medizintechnik KG · 65 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
1 open recall names at least one COVERA model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 292
- Deaths reported
- 2
- Injuries reported
- 141
- Recalls
- 1
We found 65 models of COVERA by Angiomed GmbH & Co. Medizintechnik KG in the FDA's device registry (GUDID). Together they are named in 292 adverse event reports in the FDA's MAUDE database, received between Nov 26, 2018 and Sep 15, 2026 — classified as 2 deaths, 141 injuries, 149 malfunctions.
The most frequently reported specific device problem is “Material Deformation” (58 reports).
1 FDA recall record name at least one of these models by its device identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
COVERA recalls
FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.
- Dec 22, 2022Open, Classified
An increase in the reported complaint rate for inability to deploy was identified and related to poor slide block bonding.
Z-1108-2023 · Root cause: Unknown/Undetermined by firm · names 63 of these models · Recall details · FDA record ↗
Most reported COVERA problems
Device problems
- Adverse Event Without Identified Device or Use Problem89
- Material Deformation58
- Misfire46
- Obstruction of Flow43
- Positioning Failure41
- Break32
- Loss of or Failure to Bond25
- Activation Failure20
Patient problems
- No Clinical Signs, Symptoms or Conditions134
- Restenosis70
- Stenosis37
- No Consequences Or Impact To Patient22
- Thrombosis/Thrombus16
- Pain14
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available12
- Aneurysm9
COVERA models
65 models, most reported first. Each model has its own page with its reports, recalls and device details.
- COVERA AVSM10060System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall33 reports
- COVERA AVSM08060System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall21 reports
- COVERA AVSM09060System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall18 reports
- COVERA AVSM10080System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall16 reports
- COVERA AVSM10040System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall15 reports
- COVERA AVSM09080System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall1 death14 reports
- COVERA AVFM10060System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall14 reports
- COVERA AVSM10100System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall13 reports
- COVERA AVFM09060System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall12 reports
- COVERA AVSM09100System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall11 reports
- COVERA AVSM08040System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall10 reports
- COVERA AVSM09040System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall10 reports
- COVERA AVFM10080System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall10 reports
- COVERA AVFM08060System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall9 reports
- COVERA AVFM10100System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall9 reports
- COVERA AVSM07080System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall8 reports
- COVERA AVSM08080System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall7 reports
- COVERA AVSM07060System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall6 reports
- COVERA AVSM07100System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall6 reports
- COVERA AVSM08100System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall5 reports
- COVERA AVFM08040System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall5 reports
- COVERA AVFM08080System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall5 reports
- COVERA AVSM07040System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall4 reports
- COVERA AVFM08100System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall4 reports
- COVERA AVSM06060System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall3 reports
- COVERA AVFM10040System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall3 reports
- COVERA AVSM06100System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall2 reports
- COVERA AVFM07060System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall2 reports
- COVERA AVFM09040System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall2 reports
- COVERA AVFM09080System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall2 reports
- COVERA AVSL06060System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall1 death2 reports
- COVERA AVSL09040System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall2 reports
- COVERA AVSM06080System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall1 report
- COVERA AVSM07030System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall1 report
- COVERA AVFM06100System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall1 report
- COVERA AVFM07040System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall1 report
- COVERA AVSL07100System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall1 report
- COVERA AVSL08040System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall1 report
- COVERA AVSL08080System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall1 report
- COVERA AVSM06030System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSM06040System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSM08030System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSM09030System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSM10030System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVFM06040System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVFM06080System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVFM07080System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVFM07100System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVFM09100System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSL06040System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSL06080System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSL06100System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSL07040System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSL07060System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSL07080System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSL08060System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSL08100System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSL09060System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSL09080System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSL09100System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSL10040System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSL10080System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSL10100System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 recall0 reports
- COVERA AVSL10060System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 report
- COVERA AVFL08100System, endovascular graft, arteriovenous (AV) dialysis access circuit stenosis treatment1 report
Recent COVERA adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionSep 15, 2026Material Deformation
On (b)(6) 2026, a patient underwent a stent placement procedure using a Covera Vascular Covered Stent. It was reported that additional interventions were performed in (b)(6) 2026. During the (b)(6) 2026 procedure, the stent demonstrated evidence of collapse, and balloon angioplasty was performed. On (b)(6) 2026, recurrent collapse of the proximal portion of the stent was observed. The physician performed balloon angioplasty using an 8 × 80 mm Vaccess balloon and subsequently relined the Covera stent with a Wraysody stent. There was no reported patient injury.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50769778 ↗MalfunctionSep 11, 2026Loss of or Failure to Bond; Break; Positioning Failure
On (b)(6) 2026, a 53-year-old male patient underwent a stent placement procedure using a Covera Vascular Covered Stent for the treatment of severe stenosis at the juxta-anastomotic region of a left radiocephalic arteriovenous fistula (AVF) via the left radiocephalic access site. During the procedure, it was reported that the stent failed to deploy, as the sheath did not retract when the thumbwheel was rotated. It was further reported that the internal wire did not respond to thumbwheel manipulation. The device was successfully retrieved and different brand of stent used and deployed successfully. There was no reported patient injury.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50726391 ↗MalfunctionJul 19, 2026Material Deformation
Patient problems: No Clinical Signs, Symptoms or Conditions; Reduced Blood Flow
MAUDE report 25867847 ↗MalfunctionJul 9, 2026Migration or Expulsion of Device
On b)(6) 2026, a patient underwent a stent placement procedure using a Covera Vascular Covered Stent. During the procedure, while the delivery system was being withdrawn following stent deployment, the stent migrated distally by approximately 6 cm. To secure the migrated stent, an additional stent was deployed. It was further reported that the patient has a functioning shunt and is being closely monitored to assess continued access patency and stent stability. There was no reported patient injury.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25762528 ↗MalfunctionMar 31, 2026Device Contamination with Chemical or Other Material
ON (B)(6) 2026, A PATIENT WAS PREPPED FOR A STENT PLACEMENT PROCEDURE USING COVERA VASCULAR COVERED STENT. PRIOR TO THE PROCEDURE DURING OPENING THE BOX AND THE STERILE PACKAGING OF THE STENT GRAFT, A HUMAN HAIR OR UNKNOWN PIECE OF FUZZ OR STRING WAS IDENTIFIED ATTACHED TO THE STENT IN THE STERILE PACKAGING. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO PATIENT CONTACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24742740 ↗MalfunctionMar 16, 2026Difficult or Delayed Positioning; Malposition of Device
ON (B)(6) 2026, A PATIENT UNDERWENT A STENT PLACEMENT PROCEDURE USING A COVERA VASCULAR COVERED STENT. IT WAS REPORTED THAT DURING THE PROCEDURE THE STENT WAS ALLEGEDLY FULLY DEPLOYED ALL AT ONCE AFTER ONE TURN OF THE BIG WHEEL, CAUSING INACCURATE PLACEMENT OF THE STENT. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24603011 ↗MalfunctionJan 8, 2026Misfire
ON (B)(6) 2025, A PATIENT UNDERWENT A STENT PLACEMENT PROCEDURE USING A COVERA STENT. IT WAS REPORTED THAT WHEN THE STENT WAS DEPLOYED, PART OF THE STENT ALLEGEDLY STUCK TO THE PAD AND WOULD NOT FULLY OPEN. THE PROCEDURE WAS COMPLETED USING ANOTHER STENT. THERE WERE NO REPORTED PATIENT INJURIES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24000715 ↗MalfunctionDec 19, 2025Material Deformation; Material Deformation
ON (B)(6) 2025, A PATIENT UNDERWENT A STENT PLACEMENT PROCEDURE USING COVERA. REPORTEDLY, THE STENT DEFORMED AFTER PLACEMENT IN THE PATIENT. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23847417 ↗MalfunctionDec 8, 2025Misfire; Misfire
ON (B)(6) 2025, A PATIENT UNDERWENT A STENT PLACEMENT PROCEDURE USING COVERA STENT. IT WAS REPORTED THAT DURING PROCEDURE, THE COVERA STENT WAS NOT DEPLOYED. THE PROCEDURE WAS COMPLETED BY USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23741123 ↗MalfunctionDec 1, 2025Material Deformation; Material Deformation
ON (B)(6) 2025, A PATIENT UNDERWENT A STENT PLACEMENT PROCEDURE USING A COVERA STENT. DURING PROCEDURE, IT WAS ALSO REPORTED THAT THE INNER LINING OF THE EPFTE ALLEGEDLY GOT FOLDED INWARD. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23677810 ↗MalfunctionNov 21, 2025Break; Positioning Failure; Misfire; Break; Positioning Failure; Misfire
ON (B)(6) 2025, A PATENT UNDERWENT A STENT GRAFT PLACEMENT PROCEDURE USING COVERA VASCULAR COVERED STENT IN THE ACCESS SITE OF COMMON FEMORAL ARTERY APPROACH FROM THE CONTRALATERAL SIDE. DURING THE PROCEDURE THE COVERA STENT GRAFT ALLEGEDLY FAILED TO DEPLOY. THE PROCEDURE WAS COMPLETED BY USING ANOTHER DEVICE. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23615225 ↗MalfunctionNov 17, 2025Misfire; Material Deformation; Material Twisted/Bent; Misfire; Material Deformation; Material Twisted/Bent
ON (B)(6) 2025, A PATIENT UNDERWENT A STENT PLACEMENT PROCEDURE USING COVERA VASCULAR STENT FOR THE INDICATION OF STENT PLACEMENT WAS A STENOSIS AT THE BASILIC SWING POINT TO THE AXILLARY VEIN. DURING THE PROCEDURE. IT WAS REPORTED THAT A 8X60MM STENT NARROWED AND THE DISTAL END DID NOT FULLY OPEN. THERE WAS NO ISSUE WITH THE RELEASE OF THE STENT OFF THE SHEATH. EVEN THOUGH THE STENT WAS POST DILATED WITH AN 8MM BALLOON, THE STENT REMAINED COMPRESSED AND DID NOT FULLY OPENED AFTER BALLOON DEFLATION. THE STENT APPEARED TWISTED IN THE VESSEL AND NOT PROPERLY SEATED TO THE VESSEL WALL. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23566255 ↗InjuryNov 6, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THROUGH THE RESULTS OF THE CLINICAL TRIAL THAT APPROXIMATELY ONE YEAR EIGHT MONTHS AND NINETEEN DAYS POST COVERA STENT PLACEMENT PROCEDURE FOR CEPHALIC VEIN STENOSIS, THE SUBJECT UNDERWENT ARTERIOVENOUS ACCESS CIRCUIT RE-INTERVENTION ON THE TARGET LEFT ARM FOR DECREASED ACCESS BLOOD FLOW AND PULSATILITY. IT WAS FURTHER REPORTED THAT A STANDARD PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY WAS PERFORMED DURING RE-INTERVENTION ON THE TARGET LESION ON CEPHALIC VEIN WITH RESIDUAL STENOSIS OF 15% AND NON-TARGET LESION NOT TREATED AT INDEX PROCEDURE ON THE SUBCLAVIAN VEIN WITH INITIAL STENOSIS OF 29.5% AND FINAL RESIDUAL STENOSIS OF 15%. REPORTEDLY, THE RE-INTERVENTION WAS SUCCESSFUL, AND NO NEW ACCESS WAS CREATED. THE CURRENT STATUS OF THE SUBJECT IS UNKNOWN.
Patient problems: Restenosis
MAUDE report 23484118 ↗MalfunctionNov 6, 2025Fracture; Fracture
ON (B)(6) 2025, A PATIENT UNDERWENT A STENT PLACEMENT PROCEDURE USING COVERA VASCULAR COVERED STENT. REPORTEDLY, THE STENT GOT FRACTURED. THEY HAVE HAD PREVIOUS ISSUES WITH COVERA. THERE ARE NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23484117 ↗MalfunctionOct 29, 2025Misfire; Misfire
ON (B)(6) 2025, A PATIENT UNDERWENT A STENT PLACEMENT PROCEDURE USING COVERA VASCULAR COVERED STENT FOR THE INDICATION OF VENOUS LIMB PSEUDOANEURYSM IN THE ACCESS SITE OF VENOUS LIMB OF LEFT UPPER ARM ARTERIOVENOUS GRAFT. DURING THE PROCEDURE THE STENT DID NOT DEPLOY. THE STENT SYSTEM WAS REMOVED AND FOUND THAT STENT WAS NOT FULLY DEPLOYED AND WAS STILL ON DEPLOYMENT DEVICE. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23411934 ↗
Other Angiomed GmbH & Co. Medizintechnik KG products
All Angiomed GmbH & Co. Medizintechnik KG devices →Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page