Phasix 1190616Recalls & reported problems

Davol Inc. · Phasix Mesh, 2.4" x 6.3" (6 cm x 16 cm), Rectangle · Class 2 · Implant

All models of Phasix (43)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00801741107528), received between Jun 14, 2021 and Jun 14, 2021 — classified as 1 injury.

The most frequently reported specific device problem is “Patient-Device Incompatibility” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Patient-Device Incompatibility1

Patient problems

  • Abdominal Pain1
  • Abscess1
  • Nausea1
  • Post Operative Wound Infection1
  • Vomiting1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 14, 2021Patient-Device Incompatibility; Patient-Device Incompatibility

    IT WAS REPORTED TO DAVOL THAT A PATIENT WHO IS PART OF A CLINICAL STUDY EXPERIENCED SUBCUTANEOUS ABSCESS AND SURGICAL SITE INFECTION POST-IMPLANT OF PHASIX MESH. ON (B)(6) 2021 - THE SUBJECT PATIENT UNDERWENT AN OPEN EXPLORATORY LAPAROTOMY PROCEDURE AT THE UMBILICAL SITE. A BARD/DAVOL PHASIX MESH WAS TRIMMED AND PLACED IN ONLAY FASHION. THE MESH WAS FIXATED USING SUTURE. FASCIAL CLOSURE WAS ACHIEVED WITH NON-BARD/DAVOL SUTURE, IN A CONTINUOUS RUNNING STITCH TECHNIQUE. IT WAS REPORTED THAT PROPHYLACTIC ANTIBIOTIC (METRONIDAZOLE, CEFTRIAXONE) WERE ADMINISTERED TO THE PATIENT PERI-OPERATIVELY. ON (B)(6) 2021 - THE SUBJECT PATIENT WAS DIAGNOSED WITH A SSI (SURGICAL SITE INFECTION) OF THE SUPERFICIAL SKIN LAYER AND SUBCUTANEOUS ABSCESS. THE PATIENT WAS ADMITTED TO THE HOSPITAL AND STARTED ON ORAL ANTIBIOTICS. ON (B)(6) 2021- THE SUBJECT PATIENT WAS DISCHARGED HOME TO CONTINUE THE ORAL ANTIBIOTICS. AS REPORTED, THE REPORTED ADVERSE EVENT OF HAS BEEN ASSESSED PER CLINICIAN AS POSSIBLY RELATED TO THE STUDY DEVICE AND DEFINITELY RELATED TO THE PROCEDURE. THE OUTCOME OF THE ADVERSE EVENT IS RECOVERING/RESOLVING AND THE SEVERITY IS REPORTED TO BE MODERATE.

    Patient problems: Abdominal Pain; Abscess; Nausea; Post Operative Wound Infection; Vomiting

    MAUDE report 11991621 ↗

FDA clearance and classification

The FDA regulates product code OOD (surgical film) under 21 CFR 878.3300 as a Class II device. 21 CFR 878.3300 ↗

Devices of this type normally need 510(k) clearance before sale.

The FDA lists this type of device as life-sustaining or life-supporting.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

FDA definition of this device type: To be implanted to reinforce soft tissue or bone where weakness exists. Intended to be used wherever temporary wound support is required, to reinforce soft tissues where weakness exists in the urological, gynecological, or gastrointestinal anatomy, or for the repair of hernia or other fascial defects that require the addition of a reinforcing or bridging material to obtain the desired surgical result. The absorbable protective film also may help minimize the potential for tissue attachment to the device in case of direct contact with the viscera.

Common questions about the Phasix 1190616

Has the Phasix 1190616 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00801741107528), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Phasix 1190616?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Jun 14, 2021. That report lists device problem “Patient-Device Incompatibility” (1); patient problems “Abdominal Pain” (1), “Abscess” (1) and “Nausea” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Phasix 1190616?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Phasix 1190616 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the Phasix 1190616, and is it still sold?

The FDA's device database lists Davol Inc. as the company responsible for it (brand Phasix, model 1190616). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other surgical film devices

All surgical film devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page