Peripheral Catheter Insertion Kit F218101Recalls & reported problems
Bard Access Systems, Inc. · DOT PFlex, 18G 10cm Full w/o GIVa · Class 2
All models of Peripheral Catheter Insertion Kit (54)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00801741110665), received between Jun 1, 2017 and Apr 8, 2022 — classified as 1 injury, 4 malfunctions.
The most frequently reported specific device problem is “Air Leak” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Air Leak1
- Break1
- Difficult to Insert1
- Fluid/Blood Leak1
- Hole In Material1
- Material Frayed1
- Material Integrity Problem1
- Noise, Audible1
Patient problems
- No Known Impact Or Consequence To Patient2
- Foreign Body In Patient1
- No Clinical Signs, Symptoms or Conditions1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
InjuryApr 8, 2022Break; Material Frayed; Break; Material Frayed
IT WAS REPORTED "AT APPROXIMATELY 10:30 AM TODAY, (B)(6) 2022, THERE WAS AN EQUIPMENT ISSUE WITH A MIDLINE DEVICE. MD ATTEMPTED TO INSERT A MIDLINE INTO PATIENT. THE DEVICE MALFUNCTIONED, DR CALLED SURGERY TO AID IN THE REMOVAL OF THE MIDLINE FROM PATIENT, WHICH WAS SUCCESSFUL. NO INJURY TO PATIENT; PATIENT DENIES PAIN; VA DUPLEX OF THE AFFECTED LIMB ORDERED. WE RECOVERED THE DEVICE."
Patient problems: Foreign Body In Patient
MAUDE report 14053568 ↗MalfunctionApr 1, 2022Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED BY PICC RN THAT THE CATHETER TIPS SPLIT AFTER INSERTION. NO OTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13977760 ↗MalfunctionApr 2, 2020Difficult to Insert; Difficult to Insert
IT WAS REPORTED POWERGLIDE CATHETER WILL NOT PERFORATE THE PATIENTS SKIN. THE BEVEL WILL GO IN BUT OTHERWISE EVEN WITH LARGE AMOUNTS OF FORCE THE CATHETER WILL NOT THREAD. NO OTHER INFORMATION WAS PROVIDED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9917310 ↗MalfunctionJul 18, 2017Air Leak; Hole In Material; Split
PER SALES REP, THE FACILITY REPORTED THAT THE MIDLINE IV CATHETER WAS REMOVED ON (B)(6) 2017 DUE TO CONCERN OF MALFUNCTION. NURSE REPORTED THAT THE LINE FLUSHED EASILY BUT WHEN TRYING TO ASPIRATE FOR BLOOD RETURN, AIR FILLED THE SYRINGE. THE CATHETER WAS REMOVED AND A SPLIT/HOLE WAS NOTED IN TUBING. NO PATIENT HARM WAS REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6721709 ↗MalfunctionJun 1, 2017Physical Resistance; Material Integrity Problem; Noise, Audible
PER CLINICAL SPECIALIST, THE FACILITY REPORTED THAT DURING PLACEMENT OF THE DEVICE, THE NEEDLE PIERCED AND WENT IN UNDER THE SKIN, BUT NOT INTO THE VESSEL. IT WAS STATED THAT AS THE NURSE WENT TO PUSH THE CATHETER IN, THERE WAS RESISTANCE, A POP WAS HEARD AND THE RN WENT TO PULL IT BACK AND THE GUIDEWIRE HAD BARBED. THE RN THEN UNCOILED IT AND THE WHOLE THING CAME OUT. HE STATED THAT THE INTERNAL WIRE HAD BEEN CUT WHEN THE NEEDLE ACCESSED THE SKIN AND THE WIRE MIGHT HAVE BEEN SLIGHTLY EXTENDED. THE NURSE CALLED THE PHYSICIAN WHO STATED THAT THEY DID NOT NEED TO DO AN X-RAY; THE NURSE HAD PALPATED AND COULDN¿T FEEL ANYTHING INSIDE THE PATIENT. A NEW CATHETER WAS PLACED. NO PATIENT INJURY WAS REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6605862 ↗
Other Catheter,intravascular,therapeutic,short-term less than 30 days devices
- BD Insyte Autoguard 382523Becton, Dickinson And Company · Catheter,intravascular,therapeutic,short-term less than 30 days660 reports
- BD Insyte Autoguard 382533Becton, Dickinson And Company · Catheter,intravascular,therapeutic,short-term less than 30 days2 recalls527 reports
- BD PosiFlush 306546Becton, Dickinson And Company · Catheter,intravascular,therapeutic,short-term less than 30 days1 death608 reports
- BD Insyte Autoguard Shielded IV Catheter 381823Becton, Dickinson And Company · Catheter, intravascular, therapeutic, short-term less than 30 days582 reports
- BD Insyte Autoguard 381423Becton, Dickinson And Company · Catheter,intravascular,therapeutic,short-term less than 30 days1 recall528 reports
- BD Insyte Autoguard 382544Becton, Dickinson And Company · Catheter,intravascular,therapeutic,short-term less than 30 days1 recall437 reports
- BD Nexiva, BD Q-Syte 383536Becton, Dickinson And Company · Catheter,intravascular,therapeutic,short-term less than 30 days2 recalls374 reports
- BD PosiFlush 306547Becton, Dickinson And Company · Catheter,intravascular,therapeutic,short-term less than 30 days2 recalls1 death331 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page